TY - JOUR
T1 - Hounsfield unit attenuation value can differentiate pyonephrosis from hydronephrosis and predict septic complications in patients with obstructive uropathy
AU - Boeri, Luca
AU - Fulgheri, Irene
AU - Palmisano, Franco
AU - Lievore, Elena
AU - Lorusso, Vito
AU - Ripa, Francesco
AU - D’Amico, Mario
AU - Spinelli, Matteo Giulio
AU - Salonia, Andrea
AU - Carrafiello, Gianpaolo
AU - Montanari, Emanuele
N1 - Publisher Copyright:
© 2020, The Author(s).
Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2020/12/1
Y1 - 2020/12/1
N2 - We aimed to assess the role of computerized tomography attenuation values (Hounsfield unit—HU) for differentiating pyonephrosis from hydronephrosis and for predicting postoperative infectious complications in patients with obstructive uropathy. We analysed data from 122 patients who underwent nephrostomy tube or ureteral catheter placement for obstructive uropathy. A radiologist drew the region of interest for quantitative measurement of the HU values in the hydronephrotic region of the affected kidney. Descriptive statistics and logistic regression models tested the predictive value of HU determination in differentiating pyonephrosis from hydronephrosis and in predicting postoperative sepsis. A HU cut-off value of 6.3 could diagnose the presence of pyonephrosis with 71.6% sensitivity and 71.5% specificity (AUC 0.76; 95%CI: 0.66–0.85). At multivariable logistic regression analysis HU ≥ 6.3 (p ≤ 0.001) was independently associated with pyonephrosis. Patients who developed sepsis had higher HU values (p ≤ 0.001) than those without sepsis. A HU cut-off value of 7.3 could diagnose the presence of sepsis with 76.5% sensitivity and 74.3% specificity (AUC 0.79; 95%CI: 0.71–0.90). At multivariable logistic regression analysis, HU ≥ 7.3 (p ≤ 0.001) was independently associated with sepsis, after accounting for clinical and laboratory parameters. Measuring HU values of the fluid of the dilated collecting system may be useful to differentiate pyonephrosis from hydronephrosis and to predict septic complications in patients with obstructive uropathy.
AB - We aimed to assess the role of computerized tomography attenuation values (Hounsfield unit—HU) for differentiating pyonephrosis from hydronephrosis and for predicting postoperative infectious complications in patients with obstructive uropathy. We analysed data from 122 patients who underwent nephrostomy tube or ureteral catheter placement for obstructive uropathy. A radiologist drew the region of interest for quantitative measurement of the HU values in the hydronephrotic region of the affected kidney. Descriptive statistics and logistic regression models tested the predictive value of HU determination in differentiating pyonephrosis from hydronephrosis and in predicting postoperative sepsis. A HU cut-off value of 6.3 could diagnose the presence of pyonephrosis with 71.6% sensitivity and 71.5% specificity (AUC 0.76; 95%CI: 0.66–0.85). At multivariable logistic regression analysis HU ≥ 6.3 (p ≤ 0.001) was independently associated with pyonephrosis. Patients who developed sepsis had higher HU values (p ≤ 0.001) than those without sepsis. A HU cut-off value of 7.3 could diagnose the presence of sepsis with 76.5% sensitivity and 74.3% specificity (AUC 0.79; 95%CI: 0.71–0.90). At multivariable logistic regression analysis, HU ≥ 7.3 (p ≤ 0.001) was independently associated with sepsis, after accounting for clinical and laboratory parameters. Measuring HU values of the fluid of the dilated collecting system may be useful to differentiate pyonephrosis from hydronephrosis and to predict septic complications in patients with obstructive uropathy.
UR - http://www.scopus.com/inward/record.url?scp=85094632165&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85094632165&partnerID=8YFLogxK
U2 - 10.1038/s41598-020-75672-8
DO - 10.1038/s41598-020-75672-8
M3 - Article
C2 - 33122830
AN - SCOPUS:85094632165
VL - 10
JO - Scientific Reports
JF - Scientific Reports
SN - 2045-2322
IS - 1
M1 - 18546
ER -