Errori umani nel calcolo delle Unità Monitor nella radioterapia.

Translated title of the contribution: Human errors in the calculation of the Monitor Unit in radiotherapy

R. Calandrino, G. M. Cattaneo, A. Del Vecchio, C. Fiorino, B. Longobardi, P. Signorotto

Research output: Contribution to journalArticle

Abstract

Human mistakes are a major source of error from the definition to the execution of a treatment planning. An unrevealed serious human error can cause therapy to fail therefore it is of fundamental importance to eliminate serious human errors during MU calculation. In this work the human error incidence in MU calculation is evaluated by an independent check. The investigation refers to 1,926 controls collected in about 18 months. Serious daily errors rate (errors causing a 5%, or higher, discrepancy on the daily reference dose) was 1.4% (27/1926). Serious global errors incidence (errors causing a 5%, or higher, discrepancy on the total reference dose) was 0.9% (15/1,731). The data show that the human error in MU calculation is not negligible; they also indicate the value of the independent control of MU, which is an important tool for quality assurance in radiotherapy (like in vivo dosimetry and portal imaging.

Original languageItalian
Pages (from-to)521-523
Number of pages3
JournalRadiologia Medica
Volume86
Issue number4
Publication statusPublished - Oct 1993

Fingerprint

Radiotherapy
Incidence
Research Design
Therapeutics

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Calandrino, R., Cattaneo, G. M., Del Vecchio, A., Fiorino, C., Longobardi, B., & Signorotto, P. (1993). Errori umani nel calcolo delle Unità Monitor nella radioterapia. Radiologia Medica, 86(4), 521-523.

Errori umani nel calcolo delle Unità Monitor nella radioterapia. / Calandrino, R.; Cattaneo, G. M.; Del Vecchio, A.; Fiorino, C.; Longobardi, B.; Signorotto, P.

In: Radiologia Medica, Vol. 86, No. 4, 10.1993, p. 521-523.

Research output: Contribution to journalArticle

Calandrino, R, Cattaneo, GM, Del Vecchio, A, Fiorino, C, Longobardi, B & Signorotto, P 1993, 'Errori umani nel calcolo delle Unità Monitor nella radioterapia.', Radiologia Medica, vol. 86, no. 4, pp. 521-523.
Calandrino R, Cattaneo GM, Del Vecchio A, Fiorino C, Longobardi B, Signorotto P. Errori umani nel calcolo delle Unità Monitor nella radioterapia. Radiologia Medica. 1993 Oct;86(4):521-523.
Calandrino, R. ; Cattaneo, G. M. ; Del Vecchio, A. ; Fiorino, C. ; Longobardi, B. ; Signorotto, P. / Errori umani nel calcolo delle Unità Monitor nella radioterapia. In: Radiologia Medica. 1993 ; Vol. 86, No. 4. pp. 521-523.
@article{fb37fff056634b1990759699fcf8d5ae,
title = "Errori umani nel calcolo delle Unit{\`a} Monitor nella radioterapia.",
abstract = "Human mistakes are a major source of error from the definition to the execution of a treatment planning. An unrevealed serious human error can cause therapy to fail therefore it is of fundamental importance to eliminate serious human errors during MU calculation. In this work the human error incidence in MU calculation is evaluated by an independent check. The investigation refers to 1,926 controls collected in about 18 months. Serious daily errors rate (errors causing a 5{\%}, or higher, discrepancy on the daily reference dose) was 1.4{\%} (27/1926). Serious global errors incidence (errors causing a 5{\%}, or higher, discrepancy on the total reference dose) was 0.9{\%} (15/1,731). The data show that the human error in MU calculation is not negligible; they also indicate the value of the independent control of MU, which is an important tool for quality assurance in radiotherapy (like in vivo dosimetry and portal imaging.",
author = "R. Calandrino and Cattaneo, {G. M.} and {Del Vecchio}, A. and C. Fiorino and B. Longobardi and P. Signorotto",
year = "1993",
month = "10",
language = "Italian",
volume = "86",
pages = "521--523",
journal = "Radiologia Medica",
issn = "0033-8362",
publisher = "Springer-Verlag Italia s.r.l.",
number = "4",

}

TY - JOUR

T1 - Errori umani nel calcolo delle Unità Monitor nella radioterapia.

AU - Calandrino, R.

AU - Cattaneo, G. M.

AU - Del Vecchio, A.

AU - Fiorino, C.

AU - Longobardi, B.

AU - Signorotto, P.

PY - 1993/10

Y1 - 1993/10

N2 - Human mistakes are a major source of error from the definition to the execution of a treatment planning. An unrevealed serious human error can cause therapy to fail therefore it is of fundamental importance to eliminate serious human errors during MU calculation. In this work the human error incidence in MU calculation is evaluated by an independent check. The investigation refers to 1,926 controls collected in about 18 months. Serious daily errors rate (errors causing a 5%, or higher, discrepancy on the daily reference dose) was 1.4% (27/1926). Serious global errors incidence (errors causing a 5%, or higher, discrepancy on the total reference dose) was 0.9% (15/1,731). The data show that the human error in MU calculation is not negligible; they also indicate the value of the independent control of MU, which is an important tool for quality assurance in radiotherapy (like in vivo dosimetry and portal imaging.

AB - Human mistakes are a major source of error from the definition to the execution of a treatment planning. An unrevealed serious human error can cause therapy to fail therefore it is of fundamental importance to eliminate serious human errors during MU calculation. In this work the human error incidence in MU calculation is evaluated by an independent check. The investigation refers to 1,926 controls collected in about 18 months. Serious daily errors rate (errors causing a 5%, or higher, discrepancy on the daily reference dose) was 1.4% (27/1926). Serious global errors incidence (errors causing a 5%, or higher, discrepancy on the total reference dose) was 0.9% (15/1,731). The data show that the human error in MU calculation is not negligible; they also indicate the value of the independent control of MU, which is an important tool for quality assurance in radiotherapy (like in vivo dosimetry and portal imaging.

UR - http://www.scopus.com/inward/record.url?scp=0027686027&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027686027&partnerID=8YFLogxK

M3 - Articolo

C2 - 8248592

AN - SCOPUS:0027686027

VL - 86

SP - 521

EP - 523

JO - Radiologia Medica

JF - Radiologia Medica

SN - 0033-8362

IS - 4

ER -