HUMN project initiative and review of validation, quality control and prospects for further development of automated micronucleus assays using image cytometry systems

Michael Fenech, Micheline Kirsch-Volders, Andrea Rossnerova, Radim Sram, Horst Romm, Claudia Bolognesi, Adarsh Ramakumar, Francoise Soussaline, Christian Schunck, Azeddine Elhajouji, Wagida Anwar, Stefano Bonassi

Research output: Contribution to journalArticle

41 Citations (Scopus)

Abstract

The use of micronucleus (MN) assays in in vitro genetic toxicology testing, radiation biodosimetry and population biomonitoring to study the genotoxic impacts of environment gene-interactions has steadily increased over the past two decades. As a consequence there has been a strong interest in developing automated systems to score micronuclei, a biomarker of chromosome breakage or loss, in mammalian and human cells. This paper summarises the outcomes of a workshop on this topic, organised by the HUMN project, at the 6th International Conference on Environmental Mutagenesis in Human Populations at Doha, Qatar, 2012. The aim of this paper is to summarise the outcomes of the workshop with respect to the set objectives which were: (i) Review current developments in automation of micronucleus assays by image cytometry; (ii) define the performance characteristics of automated MN scoring using image cytometry and methods of assessment for instrument validation and quality control and (iii) discuss the design of inter-laboratory comparisons and standardisation of micronucleus assays using automated image cytometry systems. It is evident that automated scoring of micronuclei by automated image cytometry using different commercially available platforms [e.g. Metafer (MetaSystems), Pathfinder™ (IMSTAR), iCyte® (Compucyte)], particularly for lymphocytes, is at a mature stage of development with good agreement between visual and automated scoring across systems (correlation factors ranging from 0.58 to 0.99). However, a standardised system of validation and calibration is required to enable more reliable comparison of data across laboratories and across platforms. This review identifies recent progress, important limitations and steps that need to be taken into account to enable the successful universal implementation of automated micronucleus assays by image cytometry.

Original languageEnglish
Pages (from-to)541-552
Number of pages12
JournalInternational Journal of Hygiene and Environmental Health
Volume216
Issue number5
DOIs
Publication statusPublished - Aug 2013

Fingerprint

Image Cytometry
Micronucleus Tests
Quality Control
Qatar
Education
Chromosome Breakage
Gene-Environment Interaction
Environmental Monitoring
Automation
Genetic Testing
Mutagenesis
Toxicology
Calibration
Population
Biomarkers
Lymphocytes
Radiation

Keywords

  • Automation
  • Cytokinesis-block
  • Image cytometry
  • Lymphocytes
  • Micronucleus

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health

Cite this

HUMN project initiative and review of validation, quality control and prospects for further development of automated micronucleus assays using image cytometry systems. / Fenech, Michael; Kirsch-Volders, Micheline; Rossnerova, Andrea; Sram, Radim; Romm, Horst; Bolognesi, Claudia; Ramakumar, Adarsh; Soussaline, Francoise; Schunck, Christian; Elhajouji, Azeddine; Anwar, Wagida; Bonassi, Stefano.

In: International Journal of Hygiene and Environmental Health, Vol. 216, No. 5, 08.2013, p. 541-552.

Research output: Contribution to journalArticle

Fenech, Michael ; Kirsch-Volders, Micheline ; Rossnerova, Andrea ; Sram, Radim ; Romm, Horst ; Bolognesi, Claudia ; Ramakumar, Adarsh ; Soussaline, Francoise ; Schunck, Christian ; Elhajouji, Azeddine ; Anwar, Wagida ; Bonassi, Stefano. / HUMN project initiative and review of validation, quality control and prospects for further development of automated micronucleus assays using image cytometry systems. In: International Journal of Hygiene and Environmental Health. 2013 ; Vol. 216, No. 5. pp. 541-552.
@article{4faabdb4c17b42e0ab74d39ca357ec85,
title = "HUMN project initiative and review of validation, quality control and prospects for further development of automated micronucleus assays using image cytometry systems",
abstract = "The use of micronucleus (MN) assays in in vitro genetic toxicology testing, radiation biodosimetry and population biomonitoring to study the genotoxic impacts of environment gene-interactions has steadily increased over the past two decades. As a consequence there has been a strong interest in developing automated systems to score micronuclei, a biomarker of chromosome breakage or loss, in mammalian and human cells. This paper summarises the outcomes of a workshop on this topic, organised by the HUMN project, at the 6th International Conference on Environmental Mutagenesis in Human Populations at Doha, Qatar, 2012. The aim of this paper is to summarise the outcomes of the workshop with respect to the set objectives which were: (i) Review current developments in automation of micronucleus assays by image cytometry; (ii) define the performance characteristics of automated MN scoring using image cytometry and methods of assessment for instrument validation and quality control and (iii) discuss the design of inter-laboratory comparisons and standardisation of micronucleus assays using automated image cytometry systems. It is evident that automated scoring of micronuclei by automated image cytometry using different commercially available platforms [e.g. Metafer (MetaSystems), Pathfinder™ (IMSTAR), iCyte{\circledR} (Compucyte)], particularly for lymphocytes, is at a mature stage of development with good agreement between visual and automated scoring across systems (correlation factors ranging from 0.58 to 0.99). However, a standardised system of validation and calibration is required to enable more reliable comparison of data across laboratories and across platforms. This review identifies recent progress, important limitations and steps that need to be taken into account to enable the successful universal implementation of automated micronucleus assays by image cytometry.",
keywords = "Automation, Cytokinesis-block, Image cytometry, Lymphocytes, Micronucleus",
author = "Michael Fenech and Micheline Kirsch-Volders and Andrea Rossnerova and Radim Sram and Horst Romm and Claudia Bolognesi and Adarsh Ramakumar and Francoise Soussaline and Christian Schunck and Azeddine Elhajouji and Wagida Anwar and Stefano Bonassi",
year = "2013",
month = "8",
doi = "10.1016/j.ijheh.2013.01.008",
language = "English",
volume = "216",
pages = "541--552",
journal = "International Journal of Hygiene and Environmental Health",
issn = "1438-4639",
publisher = "Urban und Fischer Verlag Jena",
number = "5",

}

TY - JOUR

T1 - HUMN project initiative and review of validation, quality control and prospects for further development of automated micronucleus assays using image cytometry systems

AU - Fenech, Michael

AU - Kirsch-Volders, Micheline

AU - Rossnerova, Andrea

AU - Sram, Radim

AU - Romm, Horst

AU - Bolognesi, Claudia

AU - Ramakumar, Adarsh

AU - Soussaline, Francoise

AU - Schunck, Christian

AU - Elhajouji, Azeddine

AU - Anwar, Wagida

AU - Bonassi, Stefano

PY - 2013/8

Y1 - 2013/8

N2 - The use of micronucleus (MN) assays in in vitro genetic toxicology testing, radiation biodosimetry and population biomonitoring to study the genotoxic impacts of environment gene-interactions has steadily increased over the past two decades. As a consequence there has been a strong interest in developing automated systems to score micronuclei, a biomarker of chromosome breakage or loss, in mammalian and human cells. This paper summarises the outcomes of a workshop on this topic, organised by the HUMN project, at the 6th International Conference on Environmental Mutagenesis in Human Populations at Doha, Qatar, 2012. The aim of this paper is to summarise the outcomes of the workshop with respect to the set objectives which were: (i) Review current developments in automation of micronucleus assays by image cytometry; (ii) define the performance characteristics of automated MN scoring using image cytometry and methods of assessment for instrument validation and quality control and (iii) discuss the design of inter-laboratory comparisons and standardisation of micronucleus assays using automated image cytometry systems. It is evident that automated scoring of micronuclei by automated image cytometry using different commercially available platforms [e.g. Metafer (MetaSystems), Pathfinder™ (IMSTAR), iCyte® (Compucyte)], particularly for lymphocytes, is at a mature stage of development with good agreement between visual and automated scoring across systems (correlation factors ranging from 0.58 to 0.99). However, a standardised system of validation and calibration is required to enable more reliable comparison of data across laboratories and across platforms. This review identifies recent progress, important limitations and steps that need to be taken into account to enable the successful universal implementation of automated micronucleus assays by image cytometry.

AB - The use of micronucleus (MN) assays in in vitro genetic toxicology testing, radiation biodosimetry and population biomonitoring to study the genotoxic impacts of environment gene-interactions has steadily increased over the past two decades. As a consequence there has been a strong interest in developing automated systems to score micronuclei, a biomarker of chromosome breakage or loss, in mammalian and human cells. This paper summarises the outcomes of a workshop on this topic, organised by the HUMN project, at the 6th International Conference on Environmental Mutagenesis in Human Populations at Doha, Qatar, 2012. The aim of this paper is to summarise the outcomes of the workshop with respect to the set objectives which were: (i) Review current developments in automation of micronucleus assays by image cytometry; (ii) define the performance characteristics of automated MN scoring using image cytometry and methods of assessment for instrument validation and quality control and (iii) discuss the design of inter-laboratory comparisons and standardisation of micronucleus assays using automated image cytometry systems. It is evident that automated scoring of micronuclei by automated image cytometry using different commercially available platforms [e.g. Metafer (MetaSystems), Pathfinder™ (IMSTAR), iCyte® (Compucyte)], particularly for lymphocytes, is at a mature stage of development with good agreement between visual and automated scoring across systems (correlation factors ranging from 0.58 to 0.99). However, a standardised system of validation and calibration is required to enable more reliable comparison of data across laboratories and across platforms. This review identifies recent progress, important limitations and steps that need to be taken into account to enable the successful universal implementation of automated micronucleus assays by image cytometry.

KW - Automation

KW - Cytokinesis-block

KW - Image cytometry

KW - Lymphocytes

KW - Micronucleus

UR - http://www.scopus.com/inward/record.url?scp=84880047112&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84880047112&partnerID=8YFLogxK

U2 - 10.1016/j.ijheh.2013.01.008

DO - 10.1016/j.ijheh.2013.01.008

M3 - Article

C2 - 23507632

AN - SCOPUS:84880047112

VL - 216

SP - 541

EP - 552

JO - International Journal of Hygiene and Environmental Health

JF - International Journal of Hygiene and Environmental Health

SN - 1438-4639

IS - 5

ER -