Impact of calibration fitting models on the clinical value of chromogranin A

Simona Ferraro, Giuseppe Marano, Laura Ciardi, Chiara Vendramin, Angelo S. Bongo, Giorgio Bellomo, Patrizia Boracchi, Elia M. Biganzoli

Research output: Contribution to journalArticle

Abstract

Background: The clinical relevance of chromogranin A (CgA) concentrations depends on the analytical performance of the assay. The goal of the present study was to define the clinical involvements in CgA calibration models by evaluating the confidence intervals (CIs) for values from patients who were undergoing monitoring for disease. Methods: Thirty calibration curves for the CgA assay wimmunoradiometric assay (IRMA), (CIS-BIO)x were built using linear regression (LR), and four-parameter logistic models were used to estimate CIs for patient concentrations. Results: We reported the inadequacy of the LR curve estimation procedure. We showed: 1) no evidence that the straight calibration line could fit the average responses, 2) non-constant and non-uniform variance of the replicated calibration responses. All tests performed in the analysis of variance and CI calculation for the calibration curve should be invalidated. The four-parameter logistic function yielded results for 16 curves only; this result could be due to the low number and inappropriate concentration of calibrators. This suggests that some aspects of the assay design should be reviewed. However, using the variance function estimated in this model, we could assess the CI for calibration curves and patient samples. Conclusions: We showed that the four-parameter logistic calibration model with estimated variance function should better support clinical interpretation of marker concentration changes in patients serially tested.

Original languageEnglish
Pages (from-to)1297-1303
Number of pages7
JournalClinical Chemistry and Laboratory Medicine
Volume47
Issue number10
DOIs
Publication statusPublished - Oct 1 2009

Keywords

  • Calibration
  • Chromogranin A
  • Four-parameter logistic model

ASJC Scopus subject areas

  • Clinical Biochemistry
  • Biochemistry, medical

Fingerprint Dive into the research topics of 'Impact of calibration fitting models on the clinical value of chromogranin A'. Together they form a unique fingerprint.

  • Cite this

    Ferraro, S., Marano, G., Ciardi, L., Vendramin, C., Bongo, A. S., Bellomo, G., Boracchi, P., & Biganzoli, E. M. (2009). Impact of calibration fitting models on the clinical value of chromogranin A. Clinical Chemistry and Laboratory Medicine, 47(10), 1297-1303. https://doi.org/10.1515/CCLM.2009.278