Implementation and evaluation of a 3D one-step late reconstruction algorithm for 3D positron emission tomography brain studies using median root prior

V. Bettinardi, E. Pagani, M. Gilardi, S. Alenius, K. Thielemans, M. Teras, F. Fazio

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

A fully three-dimensional (3D) one-step late (OSL), maximum a posteriori (MAP) reconstruction algorithm based on the median root prior (MRP) was implemented and evaluated for the reconstruction of 3D positron emission tomography (PET) studies. The algorithm uses the ordered subsets (OS) scheme for convergence acceleration and data update during iterations. The algorithm was implemented using the software package developed within the EU project PARAPET (www.brunel.ac.uk/∼masrppet). The MRP algorithm was evaluated using experimental phantom and real 3D PET brain studies. Various experimental set-ups in terms of activity distribution and counting statistics were considered. The performance of the algorithm was assessed by calculating figures of merit such as: contrast, coefficient of variation, activity ratio between two regions and full width at half of maximum for resolution measurements. The performance of MRP was compared with that of 3D ordered subsets-expectation maximisation (OSEM) and 3D re-projection (3DRP) algorithms. In all the experimental situations considered, MRP showed: (1) convergence to a stable solution, (2) effectiveness in noise reduction, particularly for low statistics data, (3) good preservation of spatial details. Compared with the OSEM and 3DRP algorithms, MRP provides comparable or better results depending on the parameters used for the reconstruction of the images.

Original languageEnglish
Pages (from-to)7-18
Number of pages12
JournalEuropean Journal Of Nuclear Medicine
Volume29
Issue number1
DOIs
Publication statusPublished - 2002

Fingerprint

Positron-Emission Tomography
Brain
Computer-Assisted Image Processing
Noise
Software

Keywords

  • 3D
  • Iterative reconstruction algorithm
  • Positron emission tomography

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Implementation and evaluation of a 3D one-step late reconstruction algorithm for 3D positron emission tomography brain studies using median root prior. / Bettinardi, V.; Pagani, E.; Gilardi, M.; Alenius, S.; Thielemans, K.; Teras, M.; Fazio, F.

In: European Journal Of Nuclear Medicine, Vol. 29, No. 1, 2002, p. 7-18.

Research output: Contribution to journalArticle

@article{78bacf830c714b1ba91ee794a308bf9f,
title = "Implementation and evaluation of a 3D one-step late reconstruction algorithm for 3D positron emission tomography brain studies using median root prior",
abstract = "A fully three-dimensional (3D) one-step late (OSL), maximum a posteriori (MAP) reconstruction algorithm based on the median root prior (MRP) was implemented and evaluated for the reconstruction of 3D positron emission tomography (PET) studies. The algorithm uses the ordered subsets (OS) scheme for convergence acceleration and data update during iterations. The algorithm was implemented using the software package developed within the EU project PARAPET (www.brunel.ac.uk/∼masrppet). The MRP algorithm was evaluated using experimental phantom and real 3D PET brain studies. Various experimental set-ups in terms of activity distribution and counting statistics were considered. The performance of the algorithm was assessed by calculating figures of merit such as: contrast, coefficient of variation, activity ratio between two regions and full width at half of maximum for resolution measurements. The performance of MRP was compared with that of 3D ordered subsets-expectation maximisation (OSEM) and 3D re-projection (3DRP) algorithms. In all the experimental situations considered, MRP showed: (1) convergence to a stable solution, (2) effectiveness in noise reduction, particularly for low statistics data, (3) good preservation of spatial details. Compared with the OSEM and 3DRP algorithms, MRP provides comparable or better results depending on the parameters used for the reconstruction of the images.",
keywords = "3D, Iterative reconstruction algorithm, Positron emission tomography",
author = "V. Bettinardi and E. Pagani and M. Gilardi and S. Alenius and K. Thielemans and M. Teras and F. Fazio",
year = "2002",
doi = "10.1007/s002590100651",
language = "English",
volume = "29",
pages = "7--18",
journal = "European Journal of Pediatrics",
issn = "0340-6199",
publisher = "Springer Berlin Heidelberg",
number = "1",

}

TY - JOUR

T1 - Implementation and evaluation of a 3D one-step late reconstruction algorithm for 3D positron emission tomography brain studies using median root prior

AU - Bettinardi, V.

AU - Pagani, E.

AU - Gilardi, M.

AU - Alenius, S.

AU - Thielemans, K.

AU - Teras, M.

AU - Fazio, F.

PY - 2002

Y1 - 2002

N2 - A fully three-dimensional (3D) one-step late (OSL), maximum a posteriori (MAP) reconstruction algorithm based on the median root prior (MRP) was implemented and evaluated for the reconstruction of 3D positron emission tomography (PET) studies. The algorithm uses the ordered subsets (OS) scheme for convergence acceleration and data update during iterations. The algorithm was implemented using the software package developed within the EU project PARAPET (www.brunel.ac.uk/∼masrppet). The MRP algorithm was evaluated using experimental phantom and real 3D PET brain studies. Various experimental set-ups in terms of activity distribution and counting statistics were considered. The performance of the algorithm was assessed by calculating figures of merit such as: contrast, coefficient of variation, activity ratio between two regions and full width at half of maximum for resolution measurements. The performance of MRP was compared with that of 3D ordered subsets-expectation maximisation (OSEM) and 3D re-projection (3DRP) algorithms. In all the experimental situations considered, MRP showed: (1) convergence to a stable solution, (2) effectiveness in noise reduction, particularly for low statistics data, (3) good preservation of spatial details. Compared with the OSEM and 3DRP algorithms, MRP provides comparable or better results depending on the parameters used for the reconstruction of the images.

AB - A fully three-dimensional (3D) one-step late (OSL), maximum a posteriori (MAP) reconstruction algorithm based on the median root prior (MRP) was implemented and evaluated for the reconstruction of 3D positron emission tomography (PET) studies. The algorithm uses the ordered subsets (OS) scheme for convergence acceleration and data update during iterations. The algorithm was implemented using the software package developed within the EU project PARAPET (www.brunel.ac.uk/∼masrppet). The MRP algorithm was evaluated using experimental phantom and real 3D PET brain studies. Various experimental set-ups in terms of activity distribution and counting statistics were considered. The performance of the algorithm was assessed by calculating figures of merit such as: contrast, coefficient of variation, activity ratio between two regions and full width at half of maximum for resolution measurements. The performance of MRP was compared with that of 3D ordered subsets-expectation maximisation (OSEM) and 3D re-projection (3DRP) algorithms. In all the experimental situations considered, MRP showed: (1) convergence to a stable solution, (2) effectiveness in noise reduction, particularly for low statistics data, (3) good preservation of spatial details. Compared with the OSEM and 3DRP algorithms, MRP provides comparable or better results depending on the parameters used for the reconstruction of the images.

KW - 3D

KW - Iterative reconstruction algorithm

KW - Positron emission tomography

UR - http://www.scopus.com/inward/record.url?scp=0036173387&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036173387&partnerID=8YFLogxK

U2 - 10.1007/s002590100651

DO - 10.1007/s002590100651

M3 - Article

C2 - 11807602

AN - SCOPUS:0036173387

VL - 29

SP - 7

EP - 18

JO - European Journal of Pediatrics

JF - European Journal of Pediatrics

SN - 0340-6199

IS - 1

ER -