In-vitro experimental assessment of a new robust algorithm for hip joint centre estimation

Elena De Momi, Nicola Lopomo, Pietro Cerveri, Stefano Zaffagnini, Marc R. Safran, Giancarlo Ferrigno

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

Hip joint centre (HJC) localization is used in several biomedical applications, such as movement analysis and computer-assisted orthopaedic surgery. The purpose of this study was to validate in vitro a new algorithm (MC-pivoting) for HJC computation and to compare its performances with the state-of-the-art (least square approach-LSA). The MC-pivoting algorithm iteratively searches for the 3D coordinates of the point belonging to the femoral bone that, during the circumduction of the femur around the hip joint (pivoting), runs the minimum length trajectory. The algorithm was initialized with a point distribution that can be considered close to a Monte Carlo simulation sampling all around the LSA estimate. The performances of the MC-pivoting algorithm, compared with LSA, were evaluated with tests on cadavers. Dynamic reference frames were applied on both the femur and the pelvis and were tracked by an optical localizer. Results proved the algorithm accuracy (1.7 mm±1.6, 2.3-median value±quartiles), reliability (smaller upper quartiles of the errors distribution with respect to LSA) and robustness (reduction of the errors also in case of large pelvis displacements).

Original languageEnglish
Pages (from-to)989-995
Number of pages7
JournalJournal of Biomechanics
Volume42
Issue number8
DOIs
Publication statusPublished - May 29 2009

Fingerprint

Hip Joint
Pelvis
Femur
Computer-Assisted Surgery
Orthopedics
Thigh
Least-Squares Analysis
Cadaver
Surgery
Bone
Trajectories
In Vitro Techniques
Sampling
Bone and Bones

Keywords

  • Computer-assisted orthopaedic surgery
  • Functional hip joint centre
  • Hip kinematics
  • Motion analysis

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Rehabilitation
  • Biophysics
  • Biomedical Engineering

Cite this

In-vitro experimental assessment of a new robust algorithm for hip joint centre estimation. / De Momi, Elena; Lopomo, Nicola; Cerveri, Pietro; Zaffagnini, Stefano; Safran, Marc R.; Ferrigno, Giancarlo.

In: Journal of Biomechanics, Vol. 42, No. 8, 29.05.2009, p. 989-995.

Research output: Contribution to journalArticle

De Momi, Elena ; Lopomo, Nicola ; Cerveri, Pietro ; Zaffagnini, Stefano ; Safran, Marc R. ; Ferrigno, Giancarlo. / In-vitro experimental assessment of a new robust algorithm for hip joint centre estimation. In: Journal of Biomechanics. 2009 ; Vol. 42, No. 8. pp. 989-995.
@article{93e833eb50664b21aef1545d7d1fc23d,
title = "In-vitro experimental assessment of a new robust algorithm for hip joint centre estimation",
abstract = "Hip joint centre (HJC) localization is used in several biomedical applications, such as movement analysis and computer-assisted orthopaedic surgery. The purpose of this study was to validate in vitro a new algorithm (MC-pivoting) for HJC computation and to compare its performances with the state-of-the-art (least square approach-LSA). The MC-pivoting algorithm iteratively searches for the 3D coordinates of the point belonging to the femoral bone that, during the circumduction of the femur around the hip joint (pivoting), runs the minimum length trajectory. The algorithm was initialized with a point distribution that can be considered close to a Monte Carlo simulation sampling all around the LSA estimate. The performances of the MC-pivoting algorithm, compared with LSA, were evaluated with tests on cadavers. Dynamic reference frames were applied on both the femur and the pelvis and were tracked by an optical localizer. Results proved the algorithm accuracy (1.7 mm±1.6, 2.3-median value±quartiles), reliability (smaller upper quartiles of the errors distribution with respect to LSA) and robustness (reduction of the errors also in case of large pelvis displacements).",
keywords = "Computer-assisted orthopaedic surgery, Functional hip joint centre, Hip kinematics, Motion analysis",
author = "{De Momi}, Elena and Nicola Lopomo and Pietro Cerveri and Stefano Zaffagnini and Safran, {Marc R.} and Giancarlo Ferrigno",
year = "2009",
month = "5",
day = "29",
doi = "10.1016/j.jbiomech.2009.02.031",
language = "English",
volume = "42",
pages = "989--995",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Limited",
number = "8",

}

TY - JOUR

T1 - In-vitro experimental assessment of a new robust algorithm for hip joint centre estimation

AU - De Momi, Elena

AU - Lopomo, Nicola

AU - Cerveri, Pietro

AU - Zaffagnini, Stefano

AU - Safran, Marc R.

AU - Ferrigno, Giancarlo

PY - 2009/5/29

Y1 - 2009/5/29

N2 - Hip joint centre (HJC) localization is used in several biomedical applications, such as movement analysis and computer-assisted orthopaedic surgery. The purpose of this study was to validate in vitro a new algorithm (MC-pivoting) for HJC computation and to compare its performances with the state-of-the-art (least square approach-LSA). The MC-pivoting algorithm iteratively searches for the 3D coordinates of the point belonging to the femoral bone that, during the circumduction of the femur around the hip joint (pivoting), runs the minimum length trajectory. The algorithm was initialized with a point distribution that can be considered close to a Monte Carlo simulation sampling all around the LSA estimate. The performances of the MC-pivoting algorithm, compared with LSA, were evaluated with tests on cadavers. Dynamic reference frames were applied on both the femur and the pelvis and were tracked by an optical localizer. Results proved the algorithm accuracy (1.7 mm±1.6, 2.3-median value±quartiles), reliability (smaller upper quartiles of the errors distribution with respect to LSA) and robustness (reduction of the errors also in case of large pelvis displacements).

AB - Hip joint centre (HJC) localization is used in several biomedical applications, such as movement analysis and computer-assisted orthopaedic surgery. The purpose of this study was to validate in vitro a new algorithm (MC-pivoting) for HJC computation and to compare its performances with the state-of-the-art (least square approach-LSA). The MC-pivoting algorithm iteratively searches for the 3D coordinates of the point belonging to the femoral bone that, during the circumduction of the femur around the hip joint (pivoting), runs the minimum length trajectory. The algorithm was initialized with a point distribution that can be considered close to a Monte Carlo simulation sampling all around the LSA estimate. The performances of the MC-pivoting algorithm, compared with LSA, were evaluated with tests on cadavers. Dynamic reference frames were applied on both the femur and the pelvis and were tracked by an optical localizer. Results proved the algorithm accuracy (1.7 mm±1.6, 2.3-median value±quartiles), reliability (smaller upper quartiles of the errors distribution with respect to LSA) and robustness (reduction of the errors also in case of large pelvis displacements).

KW - Computer-assisted orthopaedic surgery

KW - Functional hip joint centre

KW - Hip kinematics

KW - Motion analysis

UR - http://www.scopus.com/inward/record.url?scp=67349180188&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67349180188&partnerID=8YFLogxK

U2 - 10.1016/j.jbiomech.2009.02.031

DO - 10.1016/j.jbiomech.2009.02.031

M3 - Article

VL - 42

SP - 989

EP - 995

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290

IS - 8

ER -