In vitro long-term fatigue endurance of the secondary "cement injection stem" hip prosthesis

Luca Cristofolini, Paolo Erani, Thomas Grupp, Volkmar Jansson, Marco Viceconti

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

A secondary cementation hip stem (Cement Injection Stem; Aesculap, Tuttlingen, Germany) was designed to reduce the risk of fat embolism, and achieve precise implant position and high-quality cement mantle. A validated long-term in vitro simulation was carried out that replicated 24 years of activity of a very demanding patient. Inducible and permanent micromotions were monitored. The cement mantle was sectioned and inspected for signs of fatigue damage. The stem-cement interface was inspected for fretting. Results were compared against previously published results for a conventionally implanted stem with comparable design (Centrament; Aesculap) from which this project was derived. Comparable micromotions were found (slightly larger proximally, in correspondence to the precured centralizer). No sign of fretting was observed. All fatigue damage indicators were comparable or significantly better than those for the conventionally implanted stem. The few cement cracks found were mainly localized in proximity of a proximal drainage hole. It is foreseen that when this detail is optimized, long-term endurance will further improve.

Original languageEnglish
Pages (from-to)441-451
Number of pages11
JournalArtificial Organs
Volume31
Issue number6
DOIs
Publication statusPublished - Jun 2007

Fingerprint

Hip prostheses
Hip Prosthesis
Fatigue
Cements
Durability
Fatigue of materials
Cementation
Fat Embolism
Injections
Germany
Hip
Fatigue damage
Drainage
Oils and fats
Fats
In Vitro Techniques
Cracks

Keywords

  • Cement fracture
  • Cemented hip stem
  • Fatigue failure
  • Fretting damage
  • In vitro simulation
  • Long-term stability testing
  • Loosening
  • Micromotion
  • Preclinical validation
  • Secondary injection

ASJC Scopus subject areas

  • Biophysics

Cite this

In vitro long-term fatigue endurance of the secondary "cement injection stem" hip prosthesis. / Cristofolini, Luca; Erani, Paolo; Grupp, Thomas; Jansson, Volkmar; Viceconti, Marco.

In: Artificial Organs, Vol. 31, No. 6, 06.2007, p. 441-451.

Research output: Contribution to journalArticle

Cristofolini, Luca ; Erani, Paolo ; Grupp, Thomas ; Jansson, Volkmar ; Viceconti, Marco. / In vitro long-term fatigue endurance of the secondary "cement injection stem" hip prosthesis. In: Artificial Organs. 2007 ; Vol. 31, No. 6. pp. 441-451.
@article{95dcca8791f34adb903e58d85178292a,
title = "In vitro long-term fatigue endurance of the secondary {"}cement injection stem{"} hip prosthesis",
abstract = "A secondary cementation hip stem (Cement Injection Stem; Aesculap, Tuttlingen, Germany) was designed to reduce the risk of fat embolism, and achieve precise implant position and high-quality cement mantle. A validated long-term in vitro simulation was carried out that replicated 24 years of activity of a very demanding patient. Inducible and permanent micromotions were monitored. The cement mantle was sectioned and inspected for signs of fatigue damage. The stem-cement interface was inspected for fretting. Results were compared against previously published results for a conventionally implanted stem with comparable design (Centrament; Aesculap) from which this project was derived. Comparable micromotions were found (slightly larger proximally, in correspondence to the precured centralizer). No sign of fretting was observed. All fatigue damage indicators were comparable or significantly better than those for the conventionally implanted stem. The few cement cracks found were mainly localized in proximity of a proximal drainage hole. It is foreseen that when this detail is optimized, long-term endurance will further improve.",
keywords = "Cement fracture, Cemented hip stem, Fatigue failure, Fretting damage, In vitro simulation, Long-term stability testing, Loosening, Micromotion, Preclinical validation, Secondary injection",
author = "Luca Cristofolini and Paolo Erani and Thomas Grupp and Volkmar Jansson and Marco Viceconti",
year = "2007",
month = "6",
doi = "10.1111/j.1525-1594.2007.00407.x",
language = "English",
volume = "31",
pages = "441--451",
journal = "Artificial Organs",
issn = "0160-564X",
publisher = "Wiley-Blackwell",
number = "6",

}

TY - JOUR

T1 - In vitro long-term fatigue endurance of the secondary "cement injection stem" hip prosthesis

AU - Cristofolini, Luca

AU - Erani, Paolo

AU - Grupp, Thomas

AU - Jansson, Volkmar

AU - Viceconti, Marco

PY - 2007/6

Y1 - 2007/6

N2 - A secondary cementation hip stem (Cement Injection Stem; Aesculap, Tuttlingen, Germany) was designed to reduce the risk of fat embolism, and achieve precise implant position and high-quality cement mantle. A validated long-term in vitro simulation was carried out that replicated 24 years of activity of a very demanding patient. Inducible and permanent micromotions were monitored. The cement mantle was sectioned and inspected for signs of fatigue damage. The stem-cement interface was inspected for fretting. Results were compared against previously published results for a conventionally implanted stem with comparable design (Centrament; Aesculap) from which this project was derived. Comparable micromotions were found (slightly larger proximally, in correspondence to the precured centralizer). No sign of fretting was observed. All fatigue damage indicators were comparable or significantly better than those for the conventionally implanted stem. The few cement cracks found were mainly localized in proximity of a proximal drainage hole. It is foreseen that when this detail is optimized, long-term endurance will further improve.

AB - A secondary cementation hip stem (Cement Injection Stem; Aesculap, Tuttlingen, Germany) was designed to reduce the risk of fat embolism, and achieve precise implant position and high-quality cement mantle. A validated long-term in vitro simulation was carried out that replicated 24 years of activity of a very demanding patient. Inducible and permanent micromotions were monitored. The cement mantle was sectioned and inspected for signs of fatigue damage. The stem-cement interface was inspected for fretting. Results were compared against previously published results for a conventionally implanted stem with comparable design (Centrament; Aesculap) from which this project was derived. Comparable micromotions were found (slightly larger proximally, in correspondence to the precured centralizer). No sign of fretting was observed. All fatigue damage indicators were comparable or significantly better than those for the conventionally implanted stem. The few cement cracks found were mainly localized in proximity of a proximal drainage hole. It is foreseen that when this detail is optimized, long-term endurance will further improve.

KW - Cement fracture

KW - Cemented hip stem

KW - Fatigue failure

KW - Fretting damage

KW - In vitro simulation

KW - Long-term stability testing

KW - Loosening

KW - Micromotion

KW - Preclinical validation

KW - Secondary injection

UR - http://www.scopus.com/inward/record.url?scp=34249310578&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34249310578&partnerID=8YFLogxK

U2 - 10.1111/j.1525-1594.2007.00407.x

DO - 10.1111/j.1525-1594.2007.00407.x

M3 - Article

VL - 31

SP - 441

EP - 451

JO - Artificial Organs

JF - Artificial Organs

SN - 0160-564X

IS - 6

ER -