T1 - Inferior vena cava loop of the implantable cardioverter defibrillator endocardial lead
T2 - A possible solution to the growth problem in pediatric implantation
AU - Gasparini, Maurizio
AU - Mantica, Massimo
AU - Galimberti, Paola
AU - Coltorti, Fernando
AU - Ceriotti, Carlo
AU - Priori, Silvia G.
PY - 2000
Y1 - 2000
N2 - The ICD is an important treatment option in adults and children with life-threatening tachyarrhythmias. The possibility of lead displacement caused by growth and the lack of dedicated leads and devices poses special problems in pediatric ICD implantation. We describe our experience in three children in whom we left a redundant lead loop within the inferior vena cava (IVC) to allow for further growth. Since February 1998, three children underwent ICD implantation at our institution. A lead (screw-in) was advanced into the right ventricular apex, and a loop was created in the IVC by progressively withdrawing the stylet and pushing in the lead. Satisfactory sensing and pacing threshold values were obtained and a successful single 16-J defibrillation test was performed. No complications were encountered. After a mean follow-up of 16 months, with a mean increase in body weight and height of 4.1 ± 0.5 Kg and 6.3 ± 0.4 cm, respectively, chest X ray showed some release of additional lead length, in the absence of dislodgments, while significant changes in pacing/sensing parameters were not found. In conclusion, the creation of a loop within the IVC allows the lead to adjust for growth in children receiving an ICD. This approach is feasible and safe.
AB - The ICD is an important treatment option in adults and children with life-threatening tachyarrhythmias. The possibility of lead displacement caused by growth and the lack of dedicated leads and devices poses special problems in pediatric ICD implantation. We describe our experience in three children in whom we left a redundant lead loop within the inferior vena cava (IVC) to allow for further growth. Since February 1998, three children underwent ICD implantation at our institution. A lead (screw-in) was advanced into the right ventricular apex, and a loop was created in the IVC by progressively withdrawing the stylet and pushing in the lead. Satisfactory sensing and pacing threshold values were obtained and a successful single 16-J defibrillation test was performed. No complications were encountered. After a mean follow-up of 16 months, with a mean increase in body weight and height of 4.1 ± 0.5 Kg and 6.3 ± 0.4 cm, respectively, chest X ray showed some release of additional lead length, in the absence of dislodgments, while significant changes in pacing/sensing parameters were not found. In conclusion, the creation of a loop within the IVC allows the lead to adjust for growth in children receiving an ICD. This approach is feasible and safe.
KW - Endocardial leads
KW - Implantable cardioverter defibrillator
KW - Long QT syndrome
KW - Pediatric pacing
UR - http://www.scopus.com/inward/record.url?scp=0034494712&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034494712&partnerID=8YFLogxK
M3 - Article
C2 - 11202255
AN - SCOPUS:0034494712
VL - 23
SP - 2108
EP - 2112
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
SN - 0147-8389
IS - 12 I
ER -