Limits for use of heparin in ionized calcium determination

Giuseppe Vezzoli, Attilio Elli, Paola Palazzi, Ersilia Orazi, Elena Perticucci, Filippo Quarto di Palo, Giuseppe Bianchi

Research output: Contribution to journalArticle

Original languageEnglish
Pages (from-to)535-538
Number of pages4
JournalLa Ricerca in Clinica e in Laboratorio
Volume14
Issue number3
DOIs
Publication statusPublished - Jul 1984

Keywords

  • Calcium chelation
  • Ion-selective electrodes
  • Ionized calcium
  • Na-heparin
  • Radiometer heparin

ASJC Scopus subject areas

  • Clinical Biochemistry

Cite this

Vezzoli, G., Elli, A., Palazzi, P., Orazi, E., Perticucci, E., di Palo, F. Q., & Bianchi, G. (1984). Limits for use of heparin in ionized calcium determination. La Ricerca in Clinica e in Laboratorio, 14(3), 535-538. https://doi.org/10.1007/BF02904883

Limits for use of heparin in ionized calcium determination. / Vezzoli, Giuseppe; Elli, Attilio; Palazzi, Paola; Orazi, Ersilia; Perticucci, Elena; di Palo, Filippo Quarto; Bianchi, Giuseppe.

In: La Ricerca in Clinica e in Laboratorio, Vol. 14, No. 3, 07.1984, p. 535-538.

Research output: Contribution to journalArticle

Vezzoli, G, Elli, A, Palazzi, P, Orazi, E, Perticucci, E, di Palo, FQ & Bianchi, G 1984, 'Limits for use of heparin in ionized calcium determination', La Ricerca in Clinica e in Laboratorio, vol. 14, no. 3, pp. 535-538. https://doi.org/10.1007/BF02904883
Vezzoli, Giuseppe ; Elli, Attilio ; Palazzi, Paola ; Orazi, Ersilia ; Perticucci, Elena ; di Palo, Filippo Quarto ; Bianchi, Giuseppe. / Limits for use of heparin in ionized calcium determination. In: La Ricerca in Clinica e in Laboratorio. 1984 ; Vol. 14, No. 3. pp. 535-538.
@article{5d68e8b368a446aba1160f3593f158dd,
title = "Limits for use of heparin in ionized calcium determination",
keywords = "Calcium chelation, Ion-selective electrodes, Ionized calcium, Na-heparin, Radiometer heparin",
author = "Giuseppe Vezzoli and Attilio Elli and Paola Palazzi and Ersilia Orazi and Elena Perticucci and {di Palo}, {Filippo Quarto} and Giuseppe Bianchi",
year = "1984",
month = "7",
doi = "10.1007/BF02904883",
language = "English",
volume = "14",
pages = "535--538",
journal = "Ricerca in Clinica e in Laboratorio",
issn = "0940-5437",
publisher = "Springer Verlag",
number = "3",

}

TY - JOUR

T1 - Limits for use of heparin in ionized calcium determination

AU - Vezzoli, Giuseppe

AU - Elli, Attilio

AU - Palazzi, Paola

AU - Orazi, Ersilia

AU - Perticucci, Elena

AU - di Palo, Filippo Quarto

AU - Bianchi, Giuseppe

PY - 1984/7

Y1 - 1984/7

KW - Calcium chelation

KW - Ion-selective electrodes

KW - Ionized calcium

KW - Na-heparin

KW - Radiometer heparin

UR - http://www.scopus.com/inward/record.url?scp=0021465663&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021465663&partnerID=8YFLogxK

U2 - 10.1007/BF02904883

DO - 10.1007/BF02904883

M3 - Article

C2 - 6522964

AN - SCOPUS:0021465663

VL - 14

SP - 535

EP - 538

JO - Ricerca in Clinica e in Laboratorio

JF - Ricerca in Clinica e in Laboratorio

SN - 0940-5437

IS - 3

ER -