Magnetic resonance angiography virtual endoscopy in the assessment of pulmonary veins before radiofrequency ablation procedures for atrial fibrillation

S. Cirillo, R. Bonamini, F. Gaita, Irene Tosetti, M. De Giuseppe, M. Longo, F. Bianchi, L. Vivalda, D. Regge

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Magnetic resonance angiography (MRA) is a safe and non-invasive imaging method that can readily depict the pulmonary veins (PV), whose imaging has acquired momentum with the advent of new techniques for radiofrequency ablation of atrial fibrillation (AF). We evaluated whether virtual endoscopy from 3D MRA images (MRA-VE) is feasible in studying the morphology of PV. Fifty patients with AF underwent pre-ablative MRA (1.5 T). Images were acquired with axial T-2 weighted and 3D-SPGR sequences after intravenous administration of Gd-DTPA and automatic triggering. Postprocessing was performed by an experienced radiologist with maximum intensity projection (MIP) and virtual endoscopy software (Navigator, GEMS). The venoatrial junction was visualized with MRA-VE in 49 of 50 patients (98.0%). Twenty-seven patients (55.1%) had two ostia on both sides, 13 patients (26.5%) had two ostia on the right and a single common ostium on the left, 5 patients (10.2%) had accessory PV and 4 patients (8.2%) had both an accessory right PV and a single common ostium on the left. Flythrough navigation showed the number and spatial disposition of second-order PV branches in 48 out of 49 patients (98.0%). MRA-VE is an excellent tool for at-a-glance visualization of ostia morphology, navigation of second-generation PV branches and easy endoluminal assessment of left atrial structures in pre-ablative imaging.

Original languageEnglish
Pages (from-to)2053-2060
Number of pages8
JournalEuropean Radiology
Volume14
Issue number11
DOIs
Publication statusPublished - Nov 2004

Fingerprint

Pulmonary Veins
Magnetic Resonance Angiography
Atrial Fibrillation
Endoscopy
Ablation Techniques
Gadolinium DTPA
Intravenous Administration
Software

Keywords

  • Catheters and catheterization
  • Magnetic resonance
  • Pulmonary veins
  • Radiofrequency ablation
  • Vascular studies
  • Virtual endoscopy

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Magnetic resonance angiography virtual endoscopy in the assessment of pulmonary veins before radiofrequency ablation procedures for atrial fibrillation. / Cirillo, S.; Bonamini, R.; Gaita, F.; Tosetti, Irene; De Giuseppe, M.; Longo, M.; Bianchi, F.; Vivalda, L.; Regge, D.

In: European Radiology, Vol. 14, No. 11, 11.2004, p. 2053-2060.

Research output: Contribution to journalArticle

Cirillo, S. ; Bonamini, R. ; Gaita, F. ; Tosetti, Irene ; De Giuseppe, M. ; Longo, M. ; Bianchi, F. ; Vivalda, L. ; Regge, D. / Magnetic resonance angiography virtual endoscopy in the assessment of pulmonary veins before radiofrequency ablation procedures for atrial fibrillation. In: European Radiology. 2004 ; Vol. 14, No. 11. pp. 2053-2060.
@article{04088600e28b48feb540107c32f7f1d3,
title = "Magnetic resonance angiography virtual endoscopy in the assessment of pulmonary veins before radiofrequency ablation procedures for atrial fibrillation",
abstract = "Magnetic resonance angiography (MRA) is a safe and non-invasive imaging method that can readily depict the pulmonary veins (PV), whose imaging has acquired momentum with the advent of new techniques for radiofrequency ablation of atrial fibrillation (AF). We evaluated whether virtual endoscopy from 3D MRA images (MRA-VE) is feasible in studying the morphology of PV. Fifty patients with AF underwent pre-ablative MRA (1.5 T). Images were acquired with axial T-2 weighted and 3D-SPGR sequences after intravenous administration of Gd-DTPA and automatic triggering. Postprocessing was performed by an experienced radiologist with maximum intensity projection (MIP) and virtual endoscopy software (Navigator, GEMS). The venoatrial junction was visualized with MRA-VE in 49 of 50 patients (98.0{\%}). Twenty-seven patients (55.1{\%}) had two ostia on both sides, 13 patients (26.5{\%}) had two ostia on the right and a single common ostium on the left, 5 patients (10.2{\%}) had accessory PV and 4 patients (8.2{\%}) had both an accessory right PV and a single common ostium on the left. Flythrough navigation showed the number and spatial disposition of second-order PV branches in 48 out of 49 patients (98.0{\%}). MRA-VE is an excellent tool for at-a-glance visualization of ostia morphology, navigation of second-generation PV branches and easy endoluminal assessment of left atrial structures in pre-ablative imaging.",
keywords = "Catheters and catheterization, Magnetic resonance, Pulmonary veins, Radiofrequency ablation, Vascular studies, Virtual endoscopy",
author = "S. Cirillo and R. Bonamini and F. Gaita and Irene Tosetti and {De Giuseppe}, M. and M. Longo and F. Bianchi and L. Vivalda and D. Regge",
year = "2004",
month = "11",
doi = "10.1007/s00330-004-2406-1",
language = "English",
volume = "14",
pages = "2053--2060",
journal = "European Radiology",
issn = "0938-7994",
publisher = "Springer Verlag",
number = "11",

}

TY - JOUR

T1 - Magnetic resonance angiography virtual endoscopy in the assessment of pulmonary veins before radiofrequency ablation procedures for atrial fibrillation

AU - Cirillo, S.

AU - Bonamini, R.

AU - Gaita, F.

AU - Tosetti, Irene

AU - De Giuseppe, M.

AU - Longo, M.

AU - Bianchi, F.

AU - Vivalda, L.

AU - Regge, D.

PY - 2004/11

Y1 - 2004/11

N2 - Magnetic resonance angiography (MRA) is a safe and non-invasive imaging method that can readily depict the pulmonary veins (PV), whose imaging has acquired momentum with the advent of new techniques for radiofrequency ablation of atrial fibrillation (AF). We evaluated whether virtual endoscopy from 3D MRA images (MRA-VE) is feasible in studying the morphology of PV. Fifty patients with AF underwent pre-ablative MRA (1.5 T). Images were acquired with axial T-2 weighted and 3D-SPGR sequences after intravenous administration of Gd-DTPA and automatic triggering. Postprocessing was performed by an experienced radiologist with maximum intensity projection (MIP) and virtual endoscopy software (Navigator, GEMS). The venoatrial junction was visualized with MRA-VE in 49 of 50 patients (98.0%). Twenty-seven patients (55.1%) had two ostia on both sides, 13 patients (26.5%) had two ostia on the right and a single common ostium on the left, 5 patients (10.2%) had accessory PV and 4 patients (8.2%) had both an accessory right PV and a single common ostium on the left. Flythrough navigation showed the number and spatial disposition of second-order PV branches in 48 out of 49 patients (98.0%). MRA-VE is an excellent tool for at-a-glance visualization of ostia morphology, navigation of second-generation PV branches and easy endoluminal assessment of left atrial structures in pre-ablative imaging.

AB - Magnetic resonance angiography (MRA) is a safe and non-invasive imaging method that can readily depict the pulmonary veins (PV), whose imaging has acquired momentum with the advent of new techniques for radiofrequency ablation of atrial fibrillation (AF). We evaluated whether virtual endoscopy from 3D MRA images (MRA-VE) is feasible in studying the morphology of PV. Fifty patients with AF underwent pre-ablative MRA (1.5 T). Images were acquired with axial T-2 weighted and 3D-SPGR sequences after intravenous administration of Gd-DTPA and automatic triggering. Postprocessing was performed by an experienced radiologist with maximum intensity projection (MIP) and virtual endoscopy software (Navigator, GEMS). The venoatrial junction was visualized with MRA-VE in 49 of 50 patients (98.0%). Twenty-seven patients (55.1%) had two ostia on both sides, 13 patients (26.5%) had two ostia on the right and a single common ostium on the left, 5 patients (10.2%) had accessory PV and 4 patients (8.2%) had both an accessory right PV and a single common ostium on the left. Flythrough navigation showed the number and spatial disposition of second-order PV branches in 48 out of 49 patients (98.0%). MRA-VE is an excellent tool for at-a-glance visualization of ostia morphology, navigation of second-generation PV branches and easy endoluminal assessment of left atrial structures in pre-ablative imaging.

KW - Catheters and catheterization

KW - Magnetic resonance

KW - Pulmonary veins

KW - Radiofrequency ablation

KW - Vascular studies

KW - Virtual endoscopy

UR - http://www.scopus.com/inward/record.url?scp=8344221184&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=8344221184&partnerID=8YFLogxK

U2 - 10.1007/s00330-004-2406-1

DO - 10.1007/s00330-004-2406-1

M3 - Article

VL - 14

SP - 2053

EP - 2060

JO - European Radiology

JF - European Radiology

SN - 0938-7994

IS - 11

ER -