Magnetic resonance evaluation of autonomous thyroid nodules treated by percutaneous ethanol injection

F. Sardanelli, G. D. Giordano, E. Melani, R. C. Parodi, M. Giusti, G. Garlaschi

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Magnetic resonance (MR) imaging was used to evaluate the effect of ultrasound-guided percutaneous ethanol injection (PEI) of autonomous thyroid nodules (ATNs). Nine patients affected with ATN (3.7-32.2 mL volume) underwent PEI (4-19 mL ethanol, subdivided in 3-6 weekly procedures). MR imaging (1.5 T) was performed before each alcoholization and 1 month after the last PEI procedure with the following parameters: T1- (550/12) and T2- weighted (2200/160) spin-echo images; 4-mm slices, 10% gap; coronal planes. A further seven patients with normal thyroid function, who had undergone PEI 6- 18 months before, underwent an MR examination with the same parameters. The signal-to-noise ratio (S/N) of ATN and extranodular gland, as well as ATN volume, were evaluated on the T2-weighted images. On T1-weighted images, ATNs appeared mostly hypointense before treatment, with hyperintense areas during treatment, and were lightly hyperintense 6-18 months after treatment. S/N on T2-weighted images: extranodular gland 3.5-9.2; ATNs, before treatment 13.2-19.7, before the last procedure 7.7-11.6, 1 month after the last procedure 5.6-10.9; previously treated ATNs, 4.3-8.2. No significant volume reduction was observed with MR 1 month after the last procedure. The MR examination time was about 15 minutes. In conclusion, the effect of PEI on ATNs can be evaluated with an MR examination that is not very time consuming.

Original languageEnglish
Pages (from-to)267-274
Number of pages8
JournalMagnetic Resonance Materials in Physics, Biology, and Medicine
Volume5
Issue number4
Publication statusPublished - 1997

Fingerprint

Thyroid Nodule
Ethanol
Magnetic Resonance Spectroscopy
Injections
Magnetic Resonance Imaging
Signal-To-Noise Ratio
Therapeutics
Thyroid Gland

Keywords

  • Autonomous nodules
  • Hyperthyroidism
  • Magnetic resonance
  • Percutaneous ethanol injection
  • Thyroid
  • Thyroid nodules

ASJC Scopus subject areas

  • Biophysics
  • Genetics

Cite this

Magnetic resonance evaluation of autonomous thyroid nodules treated by percutaneous ethanol injection. / Sardanelli, F.; Giordano, G. D.; Melani, E.; Parodi, R. C.; Giusti, M.; Garlaschi, G.

In: Magnetic Resonance Materials in Physics, Biology, and Medicine, Vol. 5, No. 4, 1997, p. 267-274.

Research output: Contribution to journalArticle

Sardanelli, F. ; Giordano, G. D. ; Melani, E. ; Parodi, R. C. ; Giusti, M. ; Garlaschi, G. / Magnetic resonance evaluation of autonomous thyroid nodules treated by percutaneous ethanol injection. In: Magnetic Resonance Materials in Physics, Biology, and Medicine. 1997 ; Vol. 5, No. 4. pp. 267-274.
@article{fc97b1fafc6440b582ede8d423d4a97f,
title = "Magnetic resonance evaluation of autonomous thyroid nodules treated by percutaneous ethanol injection",
abstract = "Magnetic resonance (MR) imaging was used to evaluate the effect of ultrasound-guided percutaneous ethanol injection (PEI) of autonomous thyroid nodules (ATNs). Nine patients affected with ATN (3.7-32.2 mL volume) underwent PEI (4-19 mL ethanol, subdivided in 3-6 weekly procedures). MR imaging (1.5 T) was performed before each alcoholization and 1 month after the last PEI procedure with the following parameters: T1- (550/12) and T2- weighted (2200/160) spin-echo images; 4-mm slices, 10{\%} gap; coronal planes. A further seven patients with normal thyroid function, who had undergone PEI 6- 18 months before, underwent an MR examination with the same parameters. The signal-to-noise ratio (S/N) of ATN and extranodular gland, as well as ATN volume, were evaluated on the T2-weighted images. On T1-weighted images, ATNs appeared mostly hypointense before treatment, with hyperintense areas during treatment, and were lightly hyperintense 6-18 months after treatment. S/N on T2-weighted images: extranodular gland 3.5-9.2; ATNs, before treatment 13.2-19.7, before the last procedure 7.7-11.6, 1 month after the last procedure 5.6-10.9; previously treated ATNs, 4.3-8.2. No significant volume reduction was observed with MR 1 month after the last procedure. The MR examination time was about 15 minutes. In conclusion, the effect of PEI on ATNs can be evaluated with an MR examination that is not very time consuming.",
keywords = "Autonomous nodules, Hyperthyroidism, Magnetic resonance, Percutaneous ethanol injection, Thyroid, Thyroid nodules",
author = "F. Sardanelli and Giordano, {G. D.} and E. Melani and Parodi, {R. C.} and M. Giusti and G. Garlaschi",
year = "1997",
language = "English",
volume = "5",
pages = "267--274",
journal = "Magnetic Resonance Materials in Physics, Biology, and Medicine",
issn = "1352-8661",
publisher = "Springer Verlag",
number = "4",

}

TY - JOUR

T1 - Magnetic resonance evaluation of autonomous thyroid nodules treated by percutaneous ethanol injection

AU - Sardanelli, F.

AU - Giordano, G. D.

AU - Melani, E.

AU - Parodi, R. C.

AU - Giusti, M.

AU - Garlaschi, G.

PY - 1997

Y1 - 1997

N2 - Magnetic resonance (MR) imaging was used to evaluate the effect of ultrasound-guided percutaneous ethanol injection (PEI) of autonomous thyroid nodules (ATNs). Nine patients affected with ATN (3.7-32.2 mL volume) underwent PEI (4-19 mL ethanol, subdivided in 3-6 weekly procedures). MR imaging (1.5 T) was performed before each alcoholization and 1 month after the last PEI procedure with the following parameters: T1- (550/12) and T2- weighted (2200/160) spin-echo images; 4-mm slices, 10% gap; coronal planes. A further seven patients with normal thyroid function, who had undergone PEI 6- 18 months before, underwent an MR examination with the same parameters. The signal-to-noise ratio (S/N) of ATN and extranodular gland, as well as ATN volume, were evaluated on the T2-weighted images. On T1-weighted images, ATNs appeared mostly hypointense before treatment, with hyperintense areas during treatment, and were lightly hyperintense 6-18 months after treatment. S/N on T2-weighted images: extranodular gland 3.5-9.2; ATNs, before treatment 13.2-19.7, before the last procedure 7.7-11.6, 1 month after the last procedure 5.6-10.9; previously treated ATNs, 4.3-8.2. No significant volume reduction was observed with MR 1 month after the last procedure. The MR examination time was about 15 minutes. In conclusion, the effect of PEI on ATNs can be evaluated with an MR examination that is not very time consuming.

AB - Magnetic resonance (MR) imaging was used to evaluate the effect of ultrasound-guided percutaneous ethanol injection (PEI) of autonomous thyroid nodules (ATNs). Nine patients affected with ATN (3.7-32.2 mL volume) underwent PEI (4-19 mL ethanol, subdivided in 3-6 weekly procedures). MR imaging (1.5 T) was performed before each alcoholization and 1 month after the last PEI procedure with the following parameters: T1- (550/12) and T2- weighted (2200/160) spin-echo images; 4-mm slices, 10% gap; coronal planes. A further seven patients with normal thyroid function, who had undergone PEI 6- 18 months before, underwent an MR examination with the same parameters. The signal-to-noise ratio (S/N) of ATN and extranodular gland, as well as ATN volume, were evaluated on the T2-weighted images. On T1-weighted images, ATNs appeared mostly hypointense before treatment, with hyperintense areas during treatment, and were lightly hyperintense 6-18 months after treatment. S/N on T2-weighted images: extranodular gland 3.5-9.2; ATNs, before treatment 13.2-19.7, before the last procedure 7.7-11.6, 1 month after the last procedure 5.6-10.9; previously treated ATNs, 4.3-8.2. No significant volume reduction was observed with MR 1 month after the last procedure. The MR examination time was about 15 minutes. In conclusion, the effect of PEI on ATNs can be evaluated with an MR examination that is not very time consuming.

KW - Autonomous nodules

KW - Hyperthyroidism

KW - Magnetic resonance

KW - Percutaneous ethanol injection

KW - Thyroid

KW - Thyroid nodules

UR - http://www.scopus.com/inward/record.url?scp=0031451636&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031451636&partnerID=8YFLogxK

M3 - Article

C2 - 9440827

AN - SCOPUS:0031451636

VL - 5

SP - 267

EP - 274

JO - Magnetic Resonance Materials in Physics, Biology, and Medicine

JF - Magnetic Resonance Materials in Physics, Biology, and Medicine

SN - 1352-8661

IS - 4

ER -