Mielografia con Risonanza Magnetica con sequenza Fast Spin Echo

Translated title of the contribution: Magnetic Resonance myelography with Fast Spin Echo sequences

Tommaso Scarabino, Giuseppe Maria Giannatempo, Francesco Perfetto, Teresa Popolizio, Ugo Salvolini

Research output: Contribution to journalArticle

Abstract

A major application of Magnetic Resonance Imaging (MRI) consists in the «myelographic effect», characterized by high signal intensity of the CSF, which permits to visualize spinal subarachnoid spaces and nerve root sheaths. Such new ultrafast pulse sequences as fast spin echo (FSE) further enhance CSF high signal intensity. In addition, suppressing background with the fat suppression technique and with maximum intensity projection (MIP), a particular algorithm already used in MR angiography, FSE sequences yield 3D myelography-like images. Our study was aimed at assessing the clinical role and the reliability of this technique. Our preliminary experience is based on 21 patients with pain in the lower back and legs and on 5 healthy volunteers; all the myelography-like images were obtained with a 1.5-1 MR system (Signa, General Electric). The parameters for FSE myelography-like images included: TR = 6000, TE = 200, ETL = 32, thickness = 3 mm, matrix = 256 x 224, Nex = 4, FOV = 20 cm, fat presaturation, no phase wrap, acquisition time = 2 min 58 s. MR myelography sequences were acquired after a standard FSE T1/T2-weighted exam. MR-myelography results confirmed the diagnosis of disk herniation made on conventional T1/T2-weighted images, especially in thecal sac compression and/or amputation of nerve root sheaths. MR myelography appeared to be especially useful in migrated disk herniation or in abnormal origin of nerve roots. Moreover, it allowed full and panoramic visualization of the subarachnoid spaces and excellent definition of the thecal sac, nerve roots and nerve root sheaths. In one patient only movement artifacts affected image quality. To conclude, even though it fails to yield any functional information, MR myelography appears to be an easy, rapid and noninvasive support to conventional MRI of the lumbar spine, to replace conventional myelography.

Original languageItalian
Pages (from-to)202-206
Number of pages5
JournalRadiologia Medica
Volume91
Issue number3
Publication statusPublished - Mar 1996

Fingerprint

Myelography
Magnetic Resonance Spectroscopy
Subarachnoid Space
Fats
Magnetic Resonance Imaging
Low Back Pain
Amputation
Artifacts
Leg
Healthy Volunteers
Angiography
Spine

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Scarabino, T., Giannatempo, G. M., Perfetto, F., Popolizio, T., & Salvolini, U. (1996). Mielografia con Risonanza Magnetica con sequenza Fast Spin Echo. Radiologia Medica, 91(3), 202-206.

Mielografia con Risonanza Magnetica con sequenza Fast Spin Echo. / Scarabino, Tommaso; Giannatempo, Giuseppe Maria; Perfetto, Francesco; Popolizio, Teresa; Salvolini, Ugo.

In: Radiologia Medica, Vol. 91, No. 3, 03.1996, p. 202-206.

Research output: Contribution to journalArticle

Scarabino, T, Giannatempo, GM, Perfetto, F, Popolizio, T & Salvolini, U 1996, 'Mielografia con Risonanza Magnetica con sequenza Fast Spin Echo', Radiologia Medica, vol. 91, no. 3, pp. 202-206.
Scarabino T, Giannatempo GM, Perfetto F, Popolizio T, Salvolini U. Mielografia con Risonanza Magnetica con sequenza Fast Spin Echo. Radiologia Medica. 1996 Mar;91(3):202-206.
Scarabino, Tommaso ; Giannatempo, Giuseppe Maria ; Perfetto, Francesco ; Popolizio, Teresa ; Salvolini, Ugo. / Mielografia con Risonanza Magnetica con sequenza Fast Spin Echo. In: Radiologia Medica. 1996 ; Vol. 91, No. 3. pp. 202-206.
@article{4e447f119a8e468eaa4a96b658d37c45,
title = "Mielografia con Risonanza Magnetica con sequenza Fast Spin Echo",
abstract = "A major application of Magnetic Resonance Imaging (MRI) consists in the «myelographic effect», characterized by high signal intensity of the CSF, which permits to visualize spinal subarachnoid spaces and nerve root sheaths. Such new ultrafast pulse sequences as fast spin echo (FSE) further enhance CSF high signal intensity. In addition, suppressing background with the fat suppression technique and with maximum intensity projection (MIP), a particular algorithm already used in MR angiography, FSE sequences yield 3D myelography-like images. Our study was aimed at assessing the clinical role and the reliability of this technique. Our preliminary experience is based on 21 patients with pain in the lower back and legs and on 5 healthy volunteers; all the myelography-like images were obtained with a 1.5-1 MR system (Signa, General Electric). The parameters for FSE myelography-like images included: TR = 6000, TE = 200, ETL = 32, thickness = 3 mm, matrix = 256 x 224, Nex = 4, FOV = 20 cm, fat presaturation, no phase wrap, acquisition time = 2 min 58 s. MR myelography sequences were acquired after a standard FSE T1/T2-weighted exam. MR-myelography results confirmed the diagnosis of disk herniation made on conventional T1/T2-weighted images, especially in thecal sac compression and/or amputation of nerve root sheaths. MR myelography appeared to be especially useful in migrated disk herniation or in abnormal origin of nerve roots. Moreover, it allowed full and panoramic visualization of the subarachnoid spaces and excellent definition of the thecal sac, nerve roots and nerve root sheaths. In one patient only movement artifacts affected image quality. To conclude, even though it fails to yield any functional information, MR myelography appears to be an easy, rapid and noninvasive support to conventional MRI of the lumbar spine, to replace conventional myelography.",
keywords = "MR myelography, Spine",
author = "Tommaso Scarabino and Giannatempo, {Giuseppe Maria} and Francesco Perfetto and Teresa Popolizio and Ugo Salvolini",
year = "1996",
month = "3",
language = "Italian",
volume = "91",
pages = "202--206",
journal = "Radiologia Medica",
issn = "0033-8362",
publisher = "Springer-Verlag Italia s.r.l.",
number = "3",

}

TY - JOUR

T1 - Mielografia con Risonanza Magnetica con sequenza Fast Spin Echo

AU - Scarabino, Tommaso

AU - Giannatempo, Giuseppe Maria

AU - Perfetto, Francesco

AU - Popolizio, Teresa

AU - Salvolini, Ugo

PY - 1996/3

Y1 - 1996/3

N2 - A major application of Magnetic Resonance Imaging (MRI) consists in the «myelographic effect», characterized by high signal intensity of the CSF, which permits to visualize spinal subarachnoid spaces and nerve root sheaths. Such new ultrafast pulse sequences as fast spin echo (FSE) further enhance CSF high signal intensity. In addition, suppressing background with the fat suppression technique and with maximum intensity projection (MIP), a particular algorithm already used in MR angiography, FSE sequences yield 3D myelography-like images. Our study was aimed at assessing the clinical role and the reliability of this technique. Our preliminary experience is based on 21 patients with pain in the lower back and legs and on 5 healthy volunteers; all the myelography-like images were obtained with a 1.5-1 MR system (Signa, General Electric). The parameters for FSE myelography-like images included: TR = 6000, TE = 200, ETL = 32, thickness = 3 mm, matrix = 256 x 224, Nex = 4, FOV = 20 cm, fat presaturation, no phase wrap, acquisition time = 2 min 58 s. MR myelography sequences were acquired after a standard FSE T1/T2-weighted exam. MR-myelography results confirmed the diagnosis of disk herniation made on conventional T1/T2-weighted images, especially in thecal sac compression and/or amputation of nerve root sheaths. MR myelography appeared to be especially useful in migrated disk herniation or in abnormal origin of nerve roots. Moreover, it allowed full and panoramic visualization of the subarachnoid spaces and excellent definition of the thecal sac, nerve roots and nerve root sheaths. In one patient only movement artifacts affected image quality. To conclude, even though it fails to yield any functional information, MR myelography appears to be an easy, rapid and noninvasive support to conventional MRI of the lumbar spine, to replace conventional myelography.

AB - A major application of Magnetic Resonance Imaging (MRI) consists in the «myelographic effect», characterized by high signal intensity of the CSF, which permits to visualize spinal subarachnoid spaces and nerve root sheaths. Such new ultrafast pulse sequences as fast spin echo (FSE) further enhance CSF high signal intensity. In addition, suppressing background with the fat suppression technique and with maximum intensity projection (MIP), a particular algorithm already used in MR angiography, FSE sequences yield 3D myelography-like images. Our study was aimed at assessing the clinical role and the reliability of this technique. Our preliminary experience is based on 21 patients with pain in the lower back and legs and on 5 healthy volunteers; all the myelography-like images were obtained with a 1.5-1 MR system (Signa, General Electric). The parameters for FSE myelography-like images included: TR = 6000, TE = 200, ETL = 32, thickness = 3 mm, matrix = 256 x 224, Nex = 4, FOV = 20 cm, fat presaturation, no phase wrap, acquisition time = 2 min 58 s. MR myelography sequences were acquired after a standard FSE T1/T2-weighted exam. MR-myelography results confirmed the diagnosis of disk herniation made on conventional T1/T2-weighted images, especially in thecal sac compression and/or amputation of nerve root sheaths. MR myelography appeared to be especially useful in migrated disk herniation or in abnormal origin of nerve roots. Moreover, it allowed full and panoramic visualization of the subarachnoid spaces and excellent definition of the thecal sac, nerve roots and nerve root sheaths. In one patient only movement artifacts affected image quality. To conclude, even though it fails to yield any functional information, MR myelography appears to be an easy, rapid and noninvasive support to conventional MRI of the lumbar spine, to replace conventional myelography.

KW - MR myelography

KW - Spine

UR - http://www.scopus.com/inward/record.url?scp=0030098128&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030098128&partnerID=8YFLogxK

M3 - Articolo

C2 - 8628931

AN - SCOPUS:0030098128

VL - 91

SP - 202

EP - 206

JO - Radiologia Medica

JF - Radiologia Medica

SN - 0033-8362

IS - 3

ER -