T1 - Mitral Valve Replacement With a Third-Generation Porcine Valve
T2 - An Italian Multicentered Study
AU - Lorusso, Roberto
AU - Miceli, Antonio
AU - Gelsomino, Sandro
AU - Lio, Antonio
AU - Parise, Orlando
AU - Montisci, Andrea
AU - Vizzardi, Enrico
AU - Pacini, Davide
AU - Di Bartolomeo, Roberto
AU - Renzulli, Attilio
AU - Serraino, Filiberto G.
AU - Comoglio, Chiara
AU - Liberi, Roberta
AU - Martinelli, Gian Luca
AU - Sciangula, Alfonso
AU - Mazzola, Alessandro
AU - Faragalli, Francesca
AU - De Bonis, Michele
AU - Taramasso, Maurizio
AU - Alfieri, Ottavio
AU - Caimmi, Philippe
AU - Micalizzi, Ezio
AU - Mercogliano, Domenico
AU - Demicheli, Gloria
AU - Celiento, Michele
AU - Bortolotti, Uberto
AU - Solinas, Marco
AU - Glauber, Mattia
N1 - Publisher Copyright:
© 2020 The Society of Thoracic Surgeons
Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2020/6
Y1 - 2020/6
N2 - Background: Postoperative outcomes of a third-generation porcine bioprosthesis for mitral valve replacement (MVR) have been poorly addressed. The objective of this study was to perform an independent, retrospective, multicenter study on outcomes of patients undergoing MVR with a Mosaic (Medtronic Inc, Minneapolis, MN) porcine bioprosthesis. Methods: From 1998 to 2011, 805 patients underwent MVR with a Mosaic porcine valve in 11 cardiac centers. There were 465 female patients (58%), and the overall mean age was 73.5 ± 7 years. Associated procedures included coronary artery bypass grafting (201 patients; 24.9%), aortic valve replacement (152 patients; 18.9%), tricuspid annuloplasty (187 patients; 22.3%), and other cardiac procedures (116 patients; 14.4%). Results: Median follow-up was 44 months (interquartile range, 16 to 63), with a cumulative duration of 2.769 patient-years. Early mortality for isolated elective MVR was 3.8% (12 of 313), and overall early mortality was 7.8% (n = 63). The rate of late mortality was 3.4%/patient-year (95 late deaths). At 10 years, overall survival was 57.4% (95% confidence interval [CI], 48.8% to 67.5%), and cumulative rates of cardiac- and valve-related death were 7.4% (95% CI, 4.8% to 10.1%) and 1.1% (95% CI, 0.2% to 1.9%), respectively. The 10-year cumulative rates of thromboembolic and hemorrhagic events were 6.6% (95% CI, 1.4% to 11.8%) and 3.9% (95% CI, 0.1% to 8%), respectively, and the 10-year cumulative incidence of prosthetic valve endocarditis was 3% (95% CI, 1.2% to 4.9%). Finally, the 10-year cumulative incidences of structural valve degeneration and reoperations were 5.8% (95% CI, 0.2% to 11.5%) and 4.8% (95% CI, 0.7% to 10.3%), respectively. Conclusions: This independent, multicenter, retrospective study indicated that the Mosaic porcine bioprosthesis for MVR provides satisfactory results in terms of both early and long-term outcomes up to 14 years from its implantation.
AB - Background: Postoperative outcomes of a third-generation porcine bioprosthesis for mitral valve replacement (MVR) have been poorly addressed. The objective of this study was to perform an independent, retrospective, multicenter study on outcomes of patients undergoing MVR with a Mosaic (Medtronic Inc, Minneapolis, MN) porcine bioprosthesis. Methods: From 1998 to 2011, 805 patients underwent MVR with a Mosaic porcine valve in 11 cardiac centers. There were 465 female patients (58%), and the overall mean age was 73.5 ± 7 years. Associated procedures included coronary artery bypass grafting (201 patients; 24.9%), aortic valve replacement (152 patients; 18.9%), tricuspid annuloplasty (187 patients; 22.3%), and other cardiac procedures (116 patients; 14.4%). Results: Median follow-up was 44 months (interquartile range, 16 to 63), with a cumulative duration of 2.769 patient-years. Early mortality for isolated elective MVR was 3.8% (12 of 313), and overall early mortality was 7.8% (n = 63). The rate of late mortality was 3.4%/patient-year (95 late deaths). At 10 years, overall survival was 57.4% (95% confidence interval [CI], 48.8% to 67.5%), and cumulative rates of cardiac- and valve-related death were 7.4% (95% CI, 4.8% to 10.1%) and 1.1% (95% CI, 0.2% to 1.9%), respectively. The 10-year cumulative rates of thromboembolic and hemorrhagic events were 6.6% (95% CI, 1.4% to 11.8%) and 3.9% (95% CI, 0.1% to 8%), respectively, and the 10-year cumulative incidence of prosthetic valve endocarditis was 3% (95% CI, 1.2% to 4.9%). Finally, the 10-year cumulative incidences of structural valve degeneration and reoperations were 5.8% (95% CI, 0.2% to 11.5%) and 4.8% (95% CI, 0.7% to 10.3%), respectively. Conclusions: This independent, multicenter, retrospective study indicated that the Mosaic porcine bioprosthesis for MVR provides satisfactory results in terms of both early and long-term outcomes up to 14 years from its implantation.
UR - http://www.scopus.com/inward/record.url?scp=85084830745&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85084830745&partnerID=8YFLogxK
U2 - 10.1016/j.athoracsur.2019.08.111
DO - 10.1016/j.athoracsur.2019.08.111
M3 - Article
C2 - 31610166
AN - SCOPUS:85084830745
VL - 109
SP - 1865
EP - 1872
JO - Annals of Thoracic Surgery
JF - Annals of Thoracic Surgery
SN - 0003-4975
IS - 6
ER -