Nearly automated analysis of coronary Doppler flow velocity from transthoracic ultrasound images: Validation with manual tracings

V. Magagnin, L. Delfino, S. Cerutti, M. Turiel, E. G. Caiani

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Coronary flow velocity reserve is obtained by manual tracings of transthoracic coronary Doppler flow velocity profiles as the ratio of stress versus baseline diastolic peak velocities. This approach introduces subjectivity in the measurements and limits the information which could be exploited from the Doppler velocity profile. Accordingly, our goals were to develop a technique for nearly automated detection of Doppler coronary flow velocity profile, and automatically compute both conventional and additional amplitude, derivative and temporal parameters, and validate it with manual tracings. A total of 100 patients (17 normals, 15 patients with severe coronary stenosis, 41 with connective tissue disease and 27 with diabetes mellitus) were studied. Linear correlation and Bland-Altman analyses showed that the proposed method was highly accurate and repeatable compared to the manual measurements. Comparison between groups evidenced significant differences in some of the automated parameters, thus representing potentially additional indices useful for the noninvasive diagnosis of microcirculatory or coronary artery disease.

Original languageEnglish
Pages (from-to)483-493
Number of pages11
JournalMedical and Biological Engineering and Computing
Volume45
Issue number5
DOIs
Publication statusPublished - May 2007

Fingerprint

Flow velocity
Ultrasonics
Connective Tissue Diseases
Coronary Stenosis
Coronary Artery Disease
Diabetes Mellitus
Medical problems
Tissue
Derivatives

Keywords

  • Adaptive thresholding
  • Coronary flow velocity reserve
  • Doppler
  • Image processing

ASJC Scopus subject areas

  • Computational Theory and Mathematics
  • Computer Science Applications
  • Biomedical Engineering
  • Health Informatics
  • Health Information Management

Cite this

Nearly automated analysis of coronary Doppler flow velocity from transthoracic ultrasound images : Validation with manual tracings. / Magagnin, V.; Delfino, L.; Cerutti, S.; Turiel, M.; Caiani, E. G.

In: Medical and Biological Engineering and Computing, Vol. 45, No. 5, 05.2007, p. 483-493.

Research output: Contribution to journalArticle

@article{6654a7ffffa948caaec71be40984f0ec,
title = "Nearly automated analysis of coronary Doppler flow velocity from transthoracic ultrasound images: Validation with manual tracings",
abstract = "Coronary flow velocity reserve is obtained by manual tracings of transthoracic coronary Doppler flow velocity profiles as the ratio of stress versus baseline diastolic peak velocities. This approach introduces subjectivity in the measurements and limits the information which could be exploited from the Doppler velocity profile. Accordingly, our goals were to develop a technique for nearly automated detection of Doppler coronary flow velocity profile, and automatically compute both conventional and additional amplitude, derivative and temporal parameters, and validate it with manual tracings. A total of 100 patients (17 normals, 15 patients with severe coronary stenosis, 41 with connective tissue disease and 27 with diabetes mellitus) were studied. Linear correlation and Bland-Altman analyses showed that the proposed method was highly accurate and repeatable compared to the manual measurements. Comparison between groups evidenced significant differences in some of the automated parameters, thus representing potentially additional indices useful for the noninvasive diagnosis of microcirculatory or coronary artery disease.",
keywords = "Adaptive thresholding, Coronary flow velocity reserve, Doppler, Image processing",
author = "V. Magagnin and L. Delfino and S. Cerutti and M. Turiel and Caiani, {E. G.}",
year = "2007",
month = "5",
doi = "10.1007/s11517-007-0178-x",
language = "English",
volume = "45",
pages = "483--493",
journal = "Medical and Biological Engineering and Computing",
issn = "0140-0118",
publisher = "Springer Verlag",
number = "5",

}

TY - JOUR

T1 - Nearly automated analysis of coronary Doppler flow velocity from transthoracic ultrasound images

T2 - Validation with manual tracings

AU - Magagnin, V.

AU - Delfino, L.

AU - Cerutti, S.

AU - Turiel, M.

AU - Caiani, E. G.

PY - 2007/5

Y1 - 2007/5

N2 - Coronary flow velocity reserve is obtained by manual tracings of transthoracic coronary Doppler flow velocity profiles as the ratio of stress versus baseline diastolic peak velocities. This approach introduces subjectivity in the measurements and limits the information which could be exploited from the Doppler velocity profile. Accordingly, our goals were to develop a technique for nearly automated detection of Doppler coronary flow velocity profile, and automatically compute both conventional and additional amplitude, derivative and temporal parameters, and validate it with manual tracings. A total of 100 patients (17 normals, 15 patients with severe coronary stenosis, 41 with connective tissue disease and 27 with diabetes mellitus) were studied. Linear correlation and Bland-Altman analyses showed that the proposed method was highly accurate and repeatable compared to the manual measurements. Comparison between groups evidenced significant differences in some of the automated parameters, thus representing potentially additional indices useful for the noninvasive diagnosis of microcirculatory or coronary artery disease.

AB - Coronary flow velocity reserve is obtained by manual tracings of transthoracic coronary Doppler flow velocity profiles as the ratio of stress versus baseline diastolic peak velocities. This approach introduces subjectivity in the measurements and limits the information which could be exploited from the Doppler velocity profile. Accordingly, our goals were to develop a technique for nearly automated detection of Doppler coronary flow velocity profile, and automatically compute both conventional and additional amplitude, derivative and temporal parameters, and validate it with manual tracings. A total of 100 patients (17 normals, 15 patients with severe coronary stenosis, 41 with connective tissue disease and 27 with diabetes mellitus) were studied. Linear correlation and Bland-Altman analyses showed that the proposed method was highly accurate and repeatable compared to the manual measurements. Comparison between groups evidenced significant differences in some of the automated parameters, thus representing potentially additional indices useful for the noninvasive diagnosis of microcirculatory or coronary artery disease.

KW - Adaptive thresholding

KW - Coronary flow velocity reserve

KW - Doppler

KW - Image processing

UR - http://www.scopus.com/inward/record.url?scp=34247570606&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34247570606&partnerID=8YFLogxK

U2 - 10.1007/s11517-007-0178-x

DO - 10.1007/s11517-007-0178-x

M3 - Article

C2 - 17437142

AN - SCOPUS:34247570606

VL - 45

SP - 483

EP - 493

JO - Medical and Biological Engineering and Computing

JF - Medical and Biological Engineering and Computing

SN - 0140-0118

IS - 5

ER -