T1 - Neurological software tool for reliable atrophy measurement (NeuroSTREAM) of the lateral ventricles on clinical-quality T2-FLAIR MRI scans in multiple sclerosis
AU - Dwyer, Michael G.
AU - Silva, Diego Augusto Santos
AU - Bergsland, Niels
AU - Horakova, Dana
AU - Ramasamy, Deepa P.
AU - Durfee, Jaqueline
AU - Vaneckova, Manuela
AU - Havrdova, Eva
AU - Zivadinov, Robert
PY - 2017/7
Y1 - 2017/7
N2 - Background There is a need for a brain volume measure applicable to the clinical routine scans. Nearly every multiple sclerosis (MS) protocol includes low-resolution 2D T2-FLAIR imaging. Objectives To develop and validate cross-sectional and longitudinal brain atrophy measures on clinical-quality T2-FLAIR images in MS patients. Methods A real-world dataset from 109 MS patients from 62 MRI scanners was used to develop a lateral ventricular volume (LVV) algorithm with a longitudinal Jacobian-based extension, called NeuroSTREAM. Gold-standard LVV was calculated on high-resolution T1 1 mm, while NeuroSTREAM LVV was obtained on low-resolution T2-FLAIR 3 mm thick images. Scan-rescan reliability was assessed in 5 subjects. The variability of LVV measurement at different field strengths was tested in 76 healthy controls and 125 MS patients who obtained both 1.5T and 3T scans in 72 hours. Clinical validation of algorithm was performed in 176 MS patients who obtained serial yearly MRI 1.5T scans for 10 years. Results Correlation between gold-standard high-resolution T1 LVV and low-resolution T2-FLAIR LVV was r = 0.99, p < 0.001 and the scan-rescan coefficient of variation was 0.84%. Correlation between low-resolution T2-FLAIR LVV on 1.5T and 3T was r = 0.99, p < 0.001 and the scan-rescan coefficient of variation was 2.69% cross-sectionally and 2.08% via Jacobian integration. NeuroSTREAM showed comparable effect size (d = 0.39–0.71) in separating MS patients with and without confirmed disability progression, compared to SIENA and VIENA. Conclusions Brain atrophy measurement on clinical quality T2-FLAIR scans is feasible, accurate, reliable, and relates to clinical outcomes.
AB - Background There is a need for a brain volume measure applicable to the clinical routine scans. Nearly every multiple sclerosis (MS) protocol includes low-resolution 2D T2-FLAIR imaging. Objectives To develop and validate cross-sectional and longitudinal brain atrophy measures on clinical-quality T2-FLAIR images in MS patients. Methods A real-world dataset from 109 MS patients from 62 MRI scanners was used to develop a lateral ventricular volume (LVV) algorithm with a longitudinal Jacobian-based extension, called NeuroSTREAM. Gold-standard LVV was calculated on high-resolution T1 1 mm, while NeuroSTREAM LVV was obtained on low-resolution T2-FLAIR 3 mm thick images. Scan-rescan reliability was assessed in 5 subjects. The variability of LVV measurement at different field strengths was tested in 76 healthy controls and 125 MS patients who obtained both 1.5T and 3T scans in 72 hours. Clinical validation of algorithm was performed in 176 MS patients who obtained serial yearly MRI 1.5T scans for 10 years. Results Correlation between gold-standard high-resolution T1 LVV and low-resolution T2-FLAIR LVV was r = 0.99, p < 0.001 and the scan-rescan coefficient of variation was 0.84%. Correlation between low-resolution T2-FLAIR LVV on 1.5T and 3T was r = 0.99, p < 0.001 and the scan-rescan coefficient of variation was 2.69% cross-sectionally and 2.08% via Jacobian integration. NeuroSTREAM showed comparable effect size (d = 0.39–0.71) in separating MS patients with and without confirmed disability progression, compared to SIENA and VIENA. Conclusions Brain atrophy measurement on clinical quality T2-FLAIR scans is feasible, accurate, reliable, and relates to clinical outcomes.
KW - Automated measurement
KW - Brain atrophy
KW - Multiple sclerosis
KW - Ventricular volume
UR - http://www.scopus.com/inward/record.url?scp=85021448526&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85021448526&partnerID=8YFLogxK
U2 - 10.1016/j.nicl.2017.06.022
DO - 10.1016/j.nicl.2017.06.022
M3 - Article
AN - SCOPUS:85021448526
VL - 15
SP - 769
EP - 779
JO - NeuroImage: Clinical
JF - NeuroImage: Clinical
SN - 2213-1582
ER -