Determinazione incruenta della soglia anaerobia: validazione di un metodo automatico computerizzato.

Translated title of the contribution: Noninvasive determination of anaerobic threshold: validation of an automatic computerized method

C. D. Vizza, S. Sciomer, L. Agati, M. Penco, F. Fedele, A. Dagianti

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

The Authors propose a computerized method in order to automatically detect the anaerobic threshold by the analysis of ventilatory parameters (VE, VO2). The algorithm calculates all possible linear fits and the relative standard error of the relationship between VE and VO2 beginning from the first set of 4 data (excluding the first 2 min of exercise) and increasing of 1 pair of data until peak exercise. Subsequently the program chooses the line that fits the greatest number of data with the smallest error. The ventilatory anaerobic threshold (SA Ve) is then calculated as the point at which the relationship between VE and VO2 is no more linear (i.e. when the VE measured gets over of 2 standard errors the calculated value on the basis of the regression formula). During the first phase of the study the method was validated against invasive AT determination by arterial lactate concentration (SA La) in 14 patients (7 athletes, 7 healthy sedentary subjects) during a symptom-limited ergospirometric test (in supine position, 10 W/min until exhaustion). Subsequently we studied the method repeatability in 20 men (10 normals, 10 patients with congestive heart failure who performed 2 ergospirometric tests on separate days. The results showed a good correlation when comparing each other the VO2 (SA Ve 26.88 +/- 4.24, SA La 25.95 +/- 3.88 ml/kg/min; r = 0.88) or the onset time (SA Ve 11.8 +/- 2.42, SA La 11.61 +/- 1.8 min; r = 0.91) of anaerobic threshold determined by the 2 methods.(ABSTRACT TRUNCATED AT 250 WORDS)

Original languageItalian
Pages (from-to)793-800
Number of pages8
JournalCardiologia
Volume36
Issue number10
Publication statusPublished - Oct 1991

Fingerprint

Anaerobic Threshold
Exercise
Supine Position
Athletes
Lactic Acid
Healthy Volunteers
Heart Failure

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Vizza, C. D., Sciomer, S., Agati, L., Penco, M., Fedele, F., & Dagianti, A. (1991). Determinazione incruenta della soglia anaerobia: validazione di un metodo automatico computerizzato. Cardiologia, 36(10), 793-800.

Determinazione incruenta della soglia anaerobia : validazione di un metodo automatico computerizzato. / Vizza, C. D.; Sciomer, S.; Agati, L.; Penco, M.; Fedele, F.; Dagianti, A.

In: Cardiologia, Vol. 36, No. 10, 10.1991, p. 793-800.

Research output: Contribution to journalArticle

Vizza, CD, Sciomer, S, Agati, L, Penco, M, Fedele, F & Dagianti, A 1991, 'Determinazione incruenta della soglia anaerobia: validazione di un metodo automatico computerizzato.', Cardiologia, vol. 36, no. 10, pp. 793-800.
Vizza CD, Sciomer S, Agati L, Penco M, Fedele F, Dagianti A. Determinazione incruenta della soglia anaerobia: validazione di un metodo automatico computerizzato. Cardiologia. 1991 Oct;36(10):793-800.
Vizza, C. D. ; Sciomer, S. ; Agati, L. ; Penco, M. ; Fedele, F. ; Dagianti, A. / Determinazione incruenta della soglia anaerobia : validazione di un metodo automatico computerizzato. In: Cardiologia. 1991 ; Vol. 36, No. 10. pp. 793-800.
@article{09043d46062d4f719aac7be539fe8bc0,
title = "Determinazione incruenta della soglia anaerobia: validazione di un metodo automatico computerizzato.",
abstract = "The Authors propose a computerized method in order to automatically detect the anaerobic threshold by the analysis of ventilatory parameters (VE, VO2). The algorithm calculates all possible linear fits and the relative standard error of the relationship between VE and VO2 beginning from the first set of 4 data (excluding the first 2 min of exercise) and increasing of 1 pair of data until peak exercise. Subsequently the program chooses the line that fits the greatest number of data with the smallest error. The ventilatory anaerobic threshold (SA Ve) is then calculated as the point at which the relationship between VE and VO2 is no more linear (i.e. when the VE measured gets over of 2 standard errors the calculated value on the basis of the regression formula). During the first phase of the study the method was validated against invasive AT determination by arterial lactate concentration (SA La) in 14 patients (7 athletes, 7 healthy sedentary subjects) during a symptom-limited ergospirometric test (in supine position, 10 W/min until exhaustion). Subsequently we studied the method repeatability in 20 men (10 normals, 10 patients with congestive heart failure who performed 2 ergospirometric tests on separate days. The results showed a good correlation when comparing each other the VO2 (SA Ve 26.88 +/- 4.24, SA La 25.95 +/- 3.88 ml/kg/min; r = 0.88) or the onset time (SA Ve 11.8 +/- 2.42, SA La 11.61 +/- 1.8 min; r = 0.91) of anaerobic threshold determined by the 2 methods.(ABSTRACT TRUNCATED AT 250 WORDS)",
author = "Vizza, {C. D.} and S. Sciomer and L. Agati and M. Penco and F. Fedele and A. Dagianti",
year = "1991",
month = "10",
language = "Italian",
volume = "36",
pages = "793--800",
journal = "Cardiologia (Rome, Italy)",
issn = "0393-1978",
publisher = "Societa Italiana di Cardiologia",
number = "10",

}

TY - JOUR

T1 - Determinazione incruenta della soglia anaerobia

T2 - validazione di un metodo automatico computerizzato.

AU - Vizza, C. D.

AU - Sciomer, S.

AU - Agati, L.

AU - Penco, M.

AU - Fedele, F.

AU - Dagianti, A.

PY - 1991/10

Y1 - 1991/10

N2 - The Authors propose a computerized method in order to automatically detect the anaerobic threshold by the analysis of ventilatory parameters (VE, VO2). The algorithm calculates all possible linear fits and the relative standard error of the relationship between VE and VO2 beginning from the first set of 4 data (excluding the first 2 min of exercise) and increasing of 1 pair of data until peak exercise. Subsequently the program chooses the line that fits the greatest number of data with the smallest error. The ventilatory anaerobic threshold (SA Ve) is then calculated as the point at which the relationship between VE and VO2 is no more linear (i.e. when the VE measured gets over of 2 standard errors the calculated value on the basis of the regression formula). During the first phase of the study the method was validated against invasive AT determination by arterial lactate concentration (SA La) in 14 patients (7 athletes, 7 healthy sedentary subjects) during a symptom-limited ergospirometric test (in supine position, 10 W/min until exhaustion). Subsequently we studied the method repeatability in 20 men (10 normals, 10 patients with congestive heart failure who performed 2 ergospirometric tests on separate days. The results showed a good correlation when comparing each other the VO2 (SA Ve 26.88 +/- 4.24, SA La 25.95 +/- 3.88 ml/kg/min; r = 0.88) or the onset time (SA Ve 11.8 +/- 2.42, SA La 11.61 +/- 1.8 min; r = 0.91) of anaerobic threshold determined by the 2 methods.(ABSTRACT TRUNCATED AT 250 WORDS)

AB - The Authors propose a computerized method in order to automatically detect the anaerobic threshold by the analysis of ventilatory parameters (VE, VO2). The algorithm calculates all possible linear fits and the relative standard error of the relationship between VE and VO2 beginning from the first set of 4 data (excluding the first 2 min of exercise) and increasing of 1 pair of data until peak exercise. Subsequently the program chooses the line that fits the greatest number of data with the smallest error. The ventilatory anaerobic threshold (SA Ve) is then calculated as the point at which the relationship between VE and VO2 is no more linear (i.e. when the VE measured gets over of 2 standard errors the calculated value on the basis of the regression formula). During the first phase of the study the method was validated against invasive AT determination by arterial lactate concentration (SA La) in 14 patients (7 athletes, 7 healthy sedentary subjects) during a symptom-limited ergospirometric test (in supine position, 10 W/min until exhaustion). Subsequently we studied the method repeatability in 20 men (10 normals, 10 patients with congestive heart failure who performed 2 ergospirometric tests on separate days. The results showed a good correlation when comparing each other the VO2 (SA Ve 26.88 +/- 4.24, SA La 25.95 +/- 3.88 ml/kg/min; r = 0.88) or the onset time (SA Ve 11.8 +/- 2.42, SA La 11.61 +/- 1.8 min; r = 0.91) of anaerobic threshold determined by the 2 methods.(ABSTRACT TRUNCATED AT 250 WORDS)

UR - http://www.scopus.com/inward/record.url?scp=0026236769&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026236769&partnerID=8YFLogxK

M3 - Articolo

C2 - 1799890

AN - SCOPUS:0026236769

VL - 36

SP - 793

EP - 800

JO - Cardiologia (Rome, Italy)

JF - Cardiologia (Rome, Italy)

SN - 0393-1978

IS - 10

ER -