Optimal slice positioning for long bone CT reconstruction

M. Viceconti, A. Cappello, B. Massari, A. Bertozzi, C. Zannoni

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Aim of this work is to optimally reconstruct the 3D geometry and density distribution of long bones starting from a limited number of CT scan slices. Nowadays CT slices positioning is assessed by the radiologist starting from a 2D pre-scanning image of the bone segment. In the proposed technique, the optimal scanning sequence is searched by minimizing the overall reconstruction error of the bone density distribution, predicted by linear interpolation between the slices selected, with respect to the true 2D distribution. The technique, based on an iterative discard-insert-exchange optimization method, has been tested on both a composite and a human femur CT dataset consisting of about 450 slices. For the composite femur, the 3D root mean square reconstruction error obtained with 50 slices by a radiological protocol was equal to 12.6 grey levels, on a 0.255 range, decreasing to 6.1 for the 2D-optimized protocol. Analogously, for the human femur 11.9 and 9.6 grey levels were found respectively. The procedure was validated by comparison with 3D-optimization which gave only slightly lower errors, 5.7 and 9.1 grey levels respectively. Then, 2D-optimization provides a good sub-optimal scanning protocol for 3D bone reconstruction.

Original languageEnglish
Title of host publicationAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
PublisherIEEE
Pages674-675
Number of pages2
Volume2
Publication statusPublished - 1996
EventProceedings of the 1996 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Part 2 (of 5) - Amsterdam, Neth
Duration: Oct 31 1996Nov 3 1996

Other

OtherProceedings of the 1996 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Part 2 (of 5)
CityAmsterdam, Neth
Period10/31/9611/3/96

Fingerprint

Bone
Scanning
Computerized tomography
Composite materials
Interpolation
Geometry

ASJC Scopus subject areas

  • Bioengineering

Cite this

Viceconti, M., Cappello, A., Massari, B., Bertozzi, A., & Zannoni, C. (1996). Optimal slice positioning for long bone CT reconstruction. In Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings (Vol. 2, pp. 674-675). IEEE.

Optimal slice positioning for long bone CT reconstruction. / Viceconti, M.; Cappello, A.; Massari, B.; Bertozzi, A.; Zannoni, C.

Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. Vol. 2 IEEE, 1996. p. 674-675.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Viceconti, M, Cappello, A, Massari, B, Bertozzi, A & Zannoni, C 1996, Optimal slice positioning for long bone CT reconstruction. in Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. vol. 2, IEEE, pp. 674-675, Proceedings of the 1996 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Part 2 (of 5), Amsterdam, Neth, 10/31/96.
Viceconti M, Cappello A, Massari B, Bertozzi A, Zannoni C. Optimal slice positioning for long bone CT reconstruction. In Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. Vol. 2. IEEE. 1996. p. 674-675
Viceconti, M. ; Cappello, A. ; Massari, B. ; Bertozzi, A. ; Zannoni, C. / Optimal slice positioning for long bone CT reconstruction. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. Vol. 2 IEEE, 1996. pp. 674-675
@inproceedings{fd1ae796ff69414a829191275b052bcd,
title = "Optimal slice positioning for long bone CT reconstruction",
abstract = "Aim of this work is to optimally reconstruct the 3D geometry and density distribution of long bones starting from a limited number of CT scan slices. Nowadays CT slices positioning is assessed by the radiologist starting from a 2D pre-scanning image of the bone segment. In the proposed technique, the optimal scanning sequence is searched by minimizing the overall reconstruction error of the bone density distribution, predicted by linear interpolation between the slices selected, with respect to the true 2D distribution. The technique, based on an iterative discard-insert-exchange optimization method, has been tested on both a composite and a human femur CT dataset consisting of about 450 slices. For the composite femur, the 3D root mean square reconstruction error obtained with 50 slices by a radiological protocol was equal to 12.6 grey levels, on a 0.255 range, decreasing to 6.1 for the 2D-optimized protocol. Analogously, for the human femur 11.9 and 9.6 grey levels were found respectively. The procedure was validated by comparison with 3D-optimization which gave only slightly lower errors, 5.7 and 9.1 grey levels respectively. Then, 2D-optimization provides a good sub-optimal scanning protocol for 3D bone reconstruction.",
author = "M. Viceconti and A. Cappello and B. Massari and A. Bertozzi and C. Zannoni",
year = "1996",
language = "English",
volume = "2",
pages = "674--675",
booktitle = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",
publisher = "IEEE",

}

TY - GEN

T1 - Optimal slice positioning for long bone CT reconstruction

AU - Viceconti, M.

AU - Cappello, A.

AU - Massari, B.

AU - Bertozzi, A.

AU - Zannoni, C.

PY - 1996

Y1 - 1996

N2 - Aim of this work is to optimally reconstruct the 3D geometry and density distribution of long bones starting from a limited number of CT scan slices. Nowadays CT slices positioning is assessed by the radiologist starting from a 2D pre-scanning image of the bone segment. In the proposed technique, the optimal scanning sequence is searched by minimizing the overall reconstruction error of the bone density distribution, predicted by linear interpolation between the slices selected, with respect to the true 2D distribution. The technique, based on an iterative discard-insert-exchange optimization method, has been tested on both a composite and a human femur CT dataset consisting of about 450 slices. For the composite femur, the 3D root mean square reconstruction error obtained with 50 slices by a radiological protocol was equal to 12.6 grey levels, on a 0.255 range, decreasing to 6.1 for the 2D-optimized protocol. Analogously, for the human femur 11.9 and 9.6 grey levels were found respectively. The procedure was validated by comparison with 3D-optimization which gave only slightly lower errors, 5.7 and 9.1 grey levels respectively. Then, 2D-optimization provides a good sub-optimal scanning protocol for 3D bone reconstruction.

AB - Aim of this work is to optimally reconstruct the 3D geometry and density distribution of long bones starting from a limited number of CT scan slices. Nowadays CT slices positioning is assessed by the radiologist starting from a 2D pre-scanning image of the bone segment. In the proposed technique, the optimal scanning sequence is searched by minimizing the overall reconstruction error of the bone density distribution, predicted by linear interpolation between the slices selected, with respect to the true 2D distribution. The technique, based on an iterative discard-insert-exchange optimization method, has been tested on both a composite and a human femur CT dataset consisting of about 450 slices. For the composite femur, the 3D root mean square reconstruction error obtained with 50 slices by a radiological protocol was equal to 12.6 grey levels, on a 0.255 range, decreasing to 6.1 for the 2D-optimized protocol. Analogously, for the human femur 11.9 and 9.6 grey levels were found respectively. The procedure was validated by comparison with 3D-optimization which gave only slightly lower errors, 5.7 and 9.1 grey levels respectively. Then, 2D-optimization provides a good sub-optimal scanning protocol for 3D bone reconstruction.

UR - http://www.scopus.com/inward/record.url?scp=0030314105&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0030314105&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0030314105

VL - 2

SP - 674

EP - 675

BT - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

PB - IEEE

ER -