Oxygenator performance and artificial-native lung interaction

Francesco Epis, Mirko Belliato

Research output: Contribution to journalReview article

2 Citations (Scopus)

Abstract

During extracorporeal membrane oxygenation (ECMO), oxygen (O2) transfer (V'O2) and carbon dioxide (CO2) removal (V'CO2) are partitioned between the native lung (NL) and the membrane lung (ML), related to the patient's metabolic-hemodynamic pattern. The ML could be assimilated to a NL both in a physiological and a pathological way. ML O2 transfer (V'O2ML) is proportional to extracorporeal blood flow and the difference in O2 content between each ML side, while ML CO2 removal (V'CO2ML) can be calculated from ML gas flow and CO2 concentration at sweep gas outlet. Therefore, it is possible to calculate the ML gas exchange efficiency. Due to the ML aging process, pseudomembranous deposits on the ML fibers may completely impede gas exchange, causing a "shunt effect", significantly correlated to V'O2ML decay. Clot formation around fibers determines a ventilated but not perfused compartment, with a "dead space effect", negatively influencing V'CO2ML. Monitoring both shunt and dead space effects might be helpful to recognise ML function decline. Since ML failure is a common mechanical complication, its monitoring is critical for right ML replacement timing and it also important to understand the ECMO system performance level and for guiding the weaning procedure. ML and NL gas exchange data are usually obtained by non-continuous measurements that may fail to be timely detected in critical situations. A realtime ECMO circuit monitoring system therefore might have a significant clinical impact to improve safety, adding relevant clinical information. In our clinical practise, the integration of a real-time monitoring system with a set of standard measurements and samplings contributes to improve the safety of the procedure with a more timely and precise analysis of ECMO functioning. Moreover, an accurate analysis of NL status is fundamental in clinical setting, in order to understand the complex ECMO-patient interaction, with a multidimensional approach.

Original languageEnglish
Pages (from-to)S596-S605
JournalJournal of Thoracic Disease
Volume10
DOIs
Publication statusPublished - Mar 1 2018
Externally publishedYes

Fingerprint

Oxygenators
Lung
Membranes
Extracorporeal Membrane Oxygenation
Gases
Safety

Keywords

  • Carbon dioxide, removal
  • Extracorporeal membrane oxygenation (ECMO)
  • Monitoring, device
  • Oxygen, delivery
  • Oxygenator, membrane

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine

Cite this

Oxygenator performance and artificial-native lung interaction. / Epis, Francesco; Belliato, Mirko.

In: Journal of Thoracic Disease, Vol. 10, 01.03.2018, p. S596-S605.

Research output: Contribution to journalReview article

@article{e3cd89b654bd414697242091733ce60f,
title = "Oxygenator performance and artificial-native lung interaction",
abstract = "During extracorporeal membrane oxygenation (ECMO), oxygen (O2) transfer (V'O2) and carbon dioxide (CO2) removal (V'CO2) are partitioned between the native lung (NL) and the membrane lung (ML), related to the patient's metabolic-hemodynamic pattern. The ML could be assimilated to a NL both in a physiological and a pathological way. ML O2 transfer (V'O2ML) is proportional to extracorporeal blood flow and the difference in O2 content between each ML side, while ML CO2 removal (V'CO2ML) can be calculated from ML gas flow and CO2 concentration at sweep gas outlet. Therefore, it is possible to calculate the ML gas exchange efficiency. Due to the ML aging process, pseudomembranous deposits on the ML fibers may completely impede gas exchange, causing a {"}shunt effect{"}, significantly correlated to V'O2ML decay. Clot formation around fibers determines a ventilated but not perfused compartment, with a {"}dead space effect{"}, negatively influencing V'CO2ML. Monitoring both shunt and dead space effects might be helpful to recognise ML function decline. Since ML failure is a common mechanical complication, its monitoring is critical for right ML replacement timing and it also important to understand the ECMO system performance level and for guiding the weaning procedure. ML and NL gas exchange data are usually obtained by non-continuous measurements that may fail to be timely detected in critical situations. A realtime ECMO circuit monitoring system therefore might have a significant clinical impact to improve safety, adding relevant clinical information. In our clinical practise, the integration of a real-time monitoring system with a set of standard measurements and samplings contributes to improve the safety of the procedure with a more timely and precise analysis of ECMO functioning. Moreover, an accurate analysis of NL status is fundamental in clinical setting, in order to understand the complex ECMO-patient interaction, with a multidimensional approach.",
keywords = "Carbon dioxide, removal, Extracorporeal membrane oxygenation (ECMO), Monitoring, device, Oxygen, delivery, Oxygenator, membrane",
author = "Francesco Epis and Mirko Belliato",
year = "2018",
month = "3",
day = "1",
doi = "10.21037/jtd.2017.10.05",
language = "English",
volume = "10",
pages = "S596--S605",
journal = "Journal of Thoracic Disease",
issn = "2072-1439",
publisher = "AME Publishing Company",

}

TY - JOUR

T1 - Oxygenator performance and artificial-native lung interaction

AU - Epis, Francesco

AU - Belliato, Mirko

PY - 2018/3/1

Y1 - 2018/3/1

N2 - During extracorporeal membrane oxygenation (ECMO), oxygen (O2) transfer (V'O2) and carbon dioxide (CO2) removal (V'CO2) are partitioned between the native lung (NL) and the membrane lung (ML), related to the patient's metabolic-hemodynamic pattern. The ML could be assimilated to a NL both in a physiological and a pathological way. ML O2 transfer (V'O2ML) is proportional to extracorporeal blood flow and the difference in O2 content between each ML side, while ML CO2 removal (V'CO2ML) can be calculated from ML gas flow and CO2 concentration at sweep gas outlet. Therefore, it is possible to calculate the ML gas exchange efficiency. Due to the ML aging process, pseudomembranous deposits on the ML fibers may completely impede gas exchange, causing a "shunt effect", significantly correlated to V'O2ML decay. Clot formation around fibers determines a ventilated but not perfused compartment, with a "dead space effect", negatively influencing V'CO2ML. Monitoring both shunt and dead space effects might be helpful to recognise ML function decline. Since ML failure is a common mechanical complication, its monitoring is critical for right ML replacement timing and it also important to understand the ECMO system performance level and for guiding the weaning procedure. ML and NL gas exchange data are usually obtained by non-continuous measurements that may fail to be timely detected in critical situations. A realtime ECMO circuit monitoring system therefore might have a significant clinical impact to improve safety, adding relevant clinical information. In our clinical practise, the integration of a real-time monitoring system with a set of standard measurements and samplings contributes to improve the safety of the procedure with a more timely and precise analysis of ECMO functioning. Moreover, an accurate analysis of NL status is fundamental in clinical setting, in order to understand the complex ECMO-patient interaction, with a multidimensional approach.

AB - During extracorporeal membrane oxygenation (ECMO), oxygen (O2) transfer (V'O2) and carbon dioxide (CO2) removal (V'CO2) are partitioned between the native lung (NL) and the membrane lung (ML), related to the patient's metabolic-hemodynamic pattern. The ML could be assimilated to a NL both in a physiological and a pathological way. ML O2 transfer (V'O2ML) is proportional to extracorporeal blood flow and the difference in O2 content between each ML side, while ML CO2 removal (V'CO2ML) can be calculated from ML gas flow and CO2 concentration at sweep gas outlet. Therefore, it is possible to calculate the ML gas exchange efficiency. Due to the ML aging process, pseudomembranous deposits on the ML fibers may completely impede gas exchange, causing a "shunt effect", significantly correlated to V'O2ML decay. Clot formation around fibers determines a ventilated but not perfused compartment, with a "dead space effect", negatively influencing V'CO2ML. Monitoring both shunt and dead space effects might be helpful to recognise ML function decline. Since ML failure is a common mechanical complication, its monitoring is critical for right ML replacement timing and it also important to understand the ECMO system performance level and for guiding the weaning procedure. ML and NL gas exchange data are usually obtained by non-continuous measurements that may fail to be timely detected in critical situations. A realtime ECMO circuit monitoring system therefore might have a significant clinical impact to improve safety, adding relevant clinical information. In our clinical practise, the integration of a real-time monitoring system with a set of standard measurements and samplings contributes to improve the safety of the procedure with a more timely and precise analysis of ECMO functioning. Moreover, an accurate analysis of NL status is fundamental in clinical setting, in order to understand the complex ECMO-patient interaction, with a multidimensional approach.

KW - Carbon dioxide, removal

KW - Extracorporeal membrane oxygenation (ECMO)

KW - Monitoring, device

KW - Oxygen, delivery

KW - Oxygenator, membrane

UR - http://www.scopus.com/inward/record.url?scp=85045198512&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85045198512&partnerID=8YFLogxK

U2 - 10.21037/jtd.2017.10.05

DO - 10.21037/jtd.2017.10.05

M3 - Review article

AN - SCOPUS:85045198512

VL - 10

SP - S596-S605

JO - Journal of Thoracic Disease

JF - Journal of Thoracic Disease

SN - 2072-1439

ER -