SHUNT FISIOLOGICO DESTRO SINISTRO DURANTE INFARTO MIOCARDICO IN FASE ACUTA

Translated title of the contribution: Physiologic right left shunt during the acute stage of myocardial infarction

L. Gattinoni, M. Rota, P. Salvade

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Twenty five studies in 12 patients affected by acute myocardial infarction have been performed. A highly significant positive correlation between physiological right to left shunt, cardiac index and cardiac output was found. No correlation between physiological shunt, pulmonary artery and wedge pressure was found. Pathogenesis of physiological shunt and the meaning of its positive correlation with cardiac index and cardiac output are discussed. Therapeutic implications are also considered.

Original languageItalian
Pages (from-to)317-329
Number of pages13
JournalAnestesia e Rianimazione
Volume16
Issue number3
Publication statusPublished - 1975

Fingerprint

Myocardial Infarction
Cardiac Output
Pulmonary Wedge Pressure
Therapeutics

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Cite this

Gattinoni, L., Rota, M., & Salvade, P. (1975). SHUNT FISIOLOGICO DESTRO SINISTRO DURANTE INFARTO MIOCARDICO IN FASE ACUTA. Anestesia e Rianimazione, 16(3), 317-329.

SHUNT FISIOLOGICO DESTRO SINISTRO DURANTE INFARTO MIOCARDICO IN FASE ACUTA. / Gattinoni, L.; Rota, M.; Salvade, P.

In: Anestesia e Rianimazione, Vol. 16, No. 3, 1975, p. 317-329.

Research output: Contribution to journalArticle

Gattinoni, L, Rota, M & Salvade, P 1975, 'SHUNT FISIOLOGICO DESTRO SINISTRO DURANTE INFARTO MIOCARDICO IN FASE ACUTA', Anestesia e Rianimazione, vol. 16, no. 3, pp. 317-329.
Gattinoni, L. ; Rota, M. ; Salvade, P. / SHUNT FISIOLOGICO DESTRO SINISTRO DURANTE INFARTO MIOCARDICO IN FASE ACUTA. In: Anestesia e Rianimazione. 1975 ; Vol. 16, No. 3. pp. 317-329.
@article{07164f4378b54dbeb4a33c08739978be,
title = "SHUNT FISIOLOGICO DESTRO SINISTRO DURANTE INFARTO MIOCARDICO IN FASE ACUTA",
abstract = "Twenty five studies in 12 patients affected by acute myocardial infarction have been performed. A highly significant positive correlation between physiological right to left shunt, cardiac index and cardiac output was found. No correlation between physiological shunt, pulmonary artery and wedge pressure was found. Pathogenesis of physiological shunt and the meaning of its positive correlation with cardiac index and cardiac output are discussed. Therapeutic implications are also considered.",
author = "L. Gattinoni and M. Rota and P. Salvade",
year = "1975",
language = "Italian",
volume = "16",
pages = "317--329",
journal = "Anestesia e Rianimazione",
issn = "0570-0760",
number = "3",

}

TY - JOUR

T1 - SHUNT FISIOLOGICO DESTRO SINISTRO DURANTE INFARTO MIOCARDICO IN FASE ACUTA

AU - Gattinoni, L.

AU - Rota, M.

AU - Salvade, P.

PY - 1975

Y1 - 1975

N2 - Twenty five studies in 12 patients affected by acute myocardial infarction have been performed. A highly significant positive correlation between physiological right to left shunt, cardiac index and cardiac output was found. No correlation between physiological shunt, pulmonary artery and wedge pressure was found. Pathogenesis of physiological shunt and the meaning of its positive correlation with cardiac index and cardiac output are discussed. Therapeutic implications are also considered.

AB - Twenty five studies in 12 patients affected by acute myocardial infarction have been performed. A highly significant positive correlation between physiological right to left shunt, cardiac index and cardiac output was found. No correlation between physiological shunt, pulmonary artery and wedge pressure was found. Pathogenesis of physiological shunt and the meaning of its positive correlation with cardiac index and cardiac output are discussed. Therapeutic implications are also considered.

UR - http://www.scopus.com/inward/record.url?scp=0016724342&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0016724342&partnerID=8YFLogxK

M3 - Articolo

VL - 16

SP - 317

EP - 329

JO - Anestesia e Rianimazione

JF - Anestesia e Rianimazione

SN - 0570-0760

IS - 3

ER -