N2 - Background Lead extraction (LE) techniques have evolved from simple traction to extraction with dilators and powered sheaths with very high success rates. On the basis of the systematic implementation of a stepwise approach, we aimed to identify those characteristics that can predict the need for advanced LE techniques. Methods Between April 2005 and March 2012, 208 consecutive LE procedures were performed and 456 leads were extracted using an initial superior approach. Advanced techniques for LE (step 4 according to our stepwise approach) were used in 122 patients (58.7%). Results Younger patient age (odds ratio [OR] = 0.963, P = 0.002), longer duration of the initial implantation (OR = 1.013, P = 0.002), the number of extracted leads (OR = 2.184, P <0.001), and the presence of right ventricular defibrillator leads (OR = 2.144, P = 0.049) independently predicted the necessity of using step 4 in multivariate analysis. A prediction tool was created taking into account four categorical variables derived even from Receiver Operating Curve analysis of quantitative characteristics (age <70.7 years, implant duration > 37 months, extraction of at least two leads, one of them being a defibrillator lead). The absence of all the four characteristics was accompanied by 0% positive predictive value for the requirement of step 4 for LE, whereas the coexistence of all four risk factors is characterized by 87% requirement of advanced LE. Conclusion In most of the patients with indication for LE, use of a powered sheath extraction is necessary in order to obtain clinical success. We have identified four patient and lead characteristics that may help the operator plan the means of extraction.
AB - Background Lead extraction (LE) techniques have evolved from simple traction to extraction with dilators and powered sheaths with very high success rates. On the basis of the systematic implementation of a stepwise approach, we aimed to identify those characteristics that can predict the need for advanced LE techniques. Methods Between April 2005 and March 2012, 208 consecutive LE procedures were performed and 456 leads were extracted using an initial superior approach. Advanced techniques for LE (step 4 according to our stepwise approach) were used in 122 patients (58.7%). Results Younger patient age (odds ratio [OR] = 0.963, P = 0.002), longer duration of the initial implantation (OR = 1.013, P = 0.002), the number of extracted leads (OR = 2.184, P <0.001), and the presence of right ventricular defibrillator leads (OR = 2.144, P = 0.049) independently predicted the necessity of using step 4 in multivariate analysis. A prediction tool was created taking into account four categorical variables derived even from Receiver Operating Curve analysis of quantitative characteristics (age <70.7 years, implant duration > 37 months, extraction of at least two leads, one of them being a defibrillator lead). The absence of all the four characteristics was accompanied by 0% positive predictive value for the requirement of step 4 for LE, whereas the coexistence of all four risk factors is characterized by 87% requirement of advanced LE. Conclusion In most of the patients with indication for LE, use of a powered sheath extraction is necessary in order to obtain clinical success. We have identified four patient and lead characteristics that may help the operator plan the means of extraction.
KW - implanted cardioverter defibrillators
KW - lead extraction
KW - pacemakers
UR - http://www.scopus.com/inward/record.url?scp=84879696253&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84879696253&partnerID=8YFLogxK
U2 - 10.1111/pace.12119
DO - 10.1111/pace.12119
M3 - Article
C2 - 23510021
AN - SCOPUS:84879696253
VL - 36
SP - 837
EP - 844
JO - PACE - Pacing and Clinical Electrophysiology
JF - PACE - Pacing and Clinical Electrophysiology
SN - 0147-8389
IS - 7
ER -