Preliminary experience with the frontrunner coronary catheter: Novel device dedicated to mechanical revascularization of chronic total occlusions

Dejan Orlic, Goran Stankovic, Giuseppe Sangiorgi, Flavio Airoldi, Alaide Chieffo, Iassen Michev, Matteo Montorfano, Mauro Carlino, Nicola Corvaja, Leo Finci, Antonio Colombo

Research output: Contribution to journalArticle

46 Citations (Scopus)

Abstract

The novel device Frontrunner coronary catheter (FCC), dedicated to recanalization of chronic total occlusions (CTOs), relies on blunt microdissections inside the plaque, allowing passage of guidewire through the lesion and adjunctive angioplasty. In order to evaluate efficacy and safety of recanalization using the FCC device, we included patients with de novo or restenotic CTOs in a native coronary artery with prior failure using a guidewire or considered unsuitable for guidewire attempt in which the FCC was attempted first. Between October 2000 and June 2003, 50 patients with 50 CTOs were included in the study. Thirty-two patients had prior failure with a mechanical wire. Device and angiographic success were obtained in 25 (50%) occlusions: 53% in lesions with prior guidewire failure and 44% when FCCs were attempted first (P = 0.8). During the first year of experience, angiographic success was 42% (5 occlusions) and in the third year 75% (12 occlusions; P = 0.12). Coronary perforation occurred in nine (18.0%) patients, leading to tamponade in two (4%) patients. Perforations occurred in 5 out of 12 attempted patients during the first year and in 4 out of 38 patients in the following period (41.7% vs. 10.5%; P = 0.04). Serious advrse events occurred in five (10%) patients within 30-day follow-up. Four non-Q-wave myocardial infarctions occurred in hospital (clinical success 42%) and one death 7 days after the index procedure. The use of FCC increases the success to open chronic total occlusions refractory to mechanical guidewires or that were considered unsuitable for an attempt with a guidewire. The risk of coronary perforation due to FCC use is relatively high and it can decrease with experience.

Original languageEnglish
Pages (from-to)146-152
Number of pages7
JournalCatheterization and Cardiovascular Interventions
Volume64
Issue number2
DOIs
Publication statusPublished - Feb 2005

Fingerprint

Catheters
Equipment and Supplies
Microdissection
Angioplasty
Coronary Vessels
Myocardial Infarction
Safety

Keywords

  • Chronic total occlusions
  • Recanalization

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Radiology Nuclear Medicine and imaging

Cite this

Preliminary experience with the frontrunner coronary catheter : Novel device dedicated to mechanical revascularization of chronic total occlusions. / Orlic, Dejan; Stankovic, Goran; Sangiorgi, Giuseppe; Airoldi, Flavio; Chieffo, Alaide; Michev, Iassen; Montorfano, Matteo; Carlino, Mauro; Corvaja, Nicola; Finci, Leo; Colombo, Antonio.

In: Catheterization and Cardiovascular Interventions, Vol. 64, No. 2, 02.2005, p. 146-152.

Research output: Contribution to journalArticle

@article{f2769042ce7a48cdacd5f2ee85052550,
title = "Preliminary experience with the frontrunner coronary catheter: Novel device dedicated to mechanical revascularization of chronic total occlusions",
abstract = "The novel device Frontrunner coronary catheter (FCC), dedicated to recanalization of chronic total occlusions (CTOs), relies on blunt microdissections inside the plaque, allowing passage of guidewire through the lesion and adjunctive angioplasty. In order to evaluate efficacy and safety of recanalization using the FCC device, we included patients with de novo or restenotic CTOs in a native coronary artery with prior failure using a guidewire or considered unsuitable for guidewire attempt in which the FCC was attempted first. Between October 2000 and June 2003, 50 patients with 50 CTOs were included in the study. Thirty-two patients had prior failure with a mechanical wire. Device and angiographic success were obtained in 25 (50{\%}) occlusions: 53{\%} in lesions with prior guidewire failure and 44{\%} when FCCs were attempted first (P = 0.8). During the first year of experience, angiographic success was 42{\%} (5 occlusions) and in the third year 75{\%} (12 occlusions; P = 0.12). Coronary perforation occurred in nine (18.0{\%}) patients, leading to tamponade in two (4{\%}) patients. Perforations occurred in 5 out of 12 attempted patients during the first year and in 4 out of 38 patients in the following period (41.7{\%} vs. 10.5{\%}; P = 0.04). Serious advrse events occurred in five (10{\%}) patients within 30-day follow-up. Four non-Q-wave myocardial infarctions occurred in hospital (clinical success 42{\%}) and one death 7 days after the index procedure. The use of FCC increases the success to open chronic total occlusions refractory to mechanical guidewires or that were considered unsuitable for an attempt with a guidewire. The risk of coronary perforation due to FCC use is relatively high and it can decrease with experience.",
keywords = "Chronic total occlusions, Recanalization",
author = "Dejan Orlic and Goran Stankovic and Giuseppe Sangiorgi and Flavio Airoldi and Alaide Chieffo and Iassen Michev and Matteo Montorfano and Mauro Carlino and Nicola Corvaja and Leo Finci and Antonio Colombo",
year = "2005",
month = "2",
doi = "10.1002/ccd.20272",
language = "English",
volume = "64",
pages = "146--152",
journal = "Catheterization and Cardiovascular Interventions",
issn = "1522-1946",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Preliminary experience with the frontrunner coronary catheter

T2 - Novel device dedicated to mechanical revascularization of chronic total occlusions

AU - Orlic, Dejan

AU - Stankovic, Goran

AU - Sangiorgi, Giuseppe

AU - Airoldi, Flavio

AU - Chieffo, Alaide

AU - Michev, Iassen

AU - Montorfano, Matteo

AU - Carlino, Mauro

AU - Corvaja, Nicola

AU - Finci, Leo

AU - Colombo, Antonio

PY - 2005/2

Y1 - 2005/2

N2 - The novel device Frontrunner coronary catheter (FCC), dedicated to recanalization of chronic total occlusions (CTOs), relies on blunt microdissections inside the plaque, allowing passage of guidewire through the lesion and adjunctive angioplasty. In order to evaluate efficacy and safety of recanalization using the FCC device, we included patients with de novo or restenotic CTOs in a native coronary artery with prior failure using a guidewire or considered unsuitable for guidewire attempt in which the FCC was attempted first. Between October 2000 and June 2003, 50 patients with 50 CTOs were included in the study. Thirty-two patients had prior failure with a mechanical wire. Device and angiographic success were obtained in 25 (50%) occlusions: 53% in lesions with prior guidewire failure and 44% when FCCs were attempted first (P = 0.8). During the first year of experience, angiographic success was 42% (5 occlusions) and in the third year 75% (12 occlusions; P = 0.12). Coronary perforation occurred in nine (18.0%) patients, leading to tamponade in two (4%) patients. Perforations occurred in 5 out of 12 attempted patients during the first year and in 4 out of 38 patients in the following period (41.7% vs. 10.5%; P = 0.04). Serious advrse events occurred in five (10%) patients within 30-day follow-up. Four non-Q-wave myocardial infarctions occurred in hospital (clinical success 42%) and one death 7 days after the index procedure. The use of FCC increases the success to open chronic total occlusions refractory to mechanical guidewires or that were considered unsuitable for an attempt with a guidewire. The risk of coronary perforation due to FCC use is relatively high and it can decrease with experience.

AB - The novel device Frontrunner coronary catheter (FCC), dedicated to recanalization of chronic total occlusions (CTOs), relies on blunt microdissections inside the plaque, allowing passage of guidewire through the lesion and adjunctive angioplasty. In order to evaluate efficacy and safety of recanalization using the FCC device, we included patients with de novo or restenotic CTOs in a native coronary artery with prior failure using a guidewire or considered unsuitable for guidewire attempt in which the FCC was attempted first. Between October 2000 and June 2003, 50 patients with 50 CTOs were included in the study. Thirty-two patients had prior failure with a mechanical wire. Device and angiographic success were obtained in 25 (50%) occlusions: 53% in lesions with prior guidewire failure and 44% when FCCs were attempted first (P = 0.8). During the first year of experience, angiographic success was 42% (5 occlusions) and in the third year 75% (12 occlusions; P = 0.12). Coronary perforation occurred in nine (18.0%) patients, leading to tamponade in two (4%) patients. Perforations occurred in 5 out of 12 attempted patients during the first year and in 4 out of 38 patients in the following period (41.7% vs. 10.5%; P = 0.04). Serious advrse events occurred in five (10%) patients within 30-day follow-up. Four non-Q-wave myocardial infarctions occurred in hospital (clinical success 42%) and one death 7 days after the index procedure. The use of FCC increases the success to open chronic total occlusions refractory to mechanical guidewires or that were considered unsuitable for an attempt with a guidewire. The risk of coronary perforation due to FCC use is relatively high and it can decrease with experience.

KW - Chronic total occlusions

KW - Recanalization

UR - http://www.scopus.com/inward/record.url?scp=19944433175&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=19944433175&partnerID=8YFLogxK

U2 - 10.1002/ccd.20272

DO - 10.1002/ccd.20272

M3 - Article

C2 - 15678451

AN - SCOPUS:19944433175

VL - 64

SP - 146

EP - 152

JO - Catheterization and Cardiovascular Interventions

JF - Catheterization and Cardiovascular Interventions

SN - 1522-1946

IS - 2

ER -