Prognostic factors in lower limb joint arthroplasty

S. Giannini, Fabio Catani, A. Ensini, G. Cucca, L. Bragonzoni, S. Toksvig-Larsen

Research output: Contribution to journalArticle

Abstract

A study was carried out to determine the influence of prosthesis design on fixation and to detect patients at high risk of mechanical aseptic loosening. The migration of implant in-vivo was quantified. Subsidence of hip arthroplasty was not found while the greater displacement was found in the tip of the stem.

Original languageEnglish
Pages (from-to)1007-1012
Number of pages6
JournalKey Engineering Materials
Volume192-195
Publication statusPublished - 2001

Fingerprint

Arthroplasty
Subsidence
Prostheses and Implants

ASJC Scopus subject areas

  • Chemical Engineering (miscellaneous)
  • Ceramics and Composites

Cite this

Giannini, S., Catani, F., Ensini, A., Cucca, G., Bragonzoni, L., & Toksvig-Larsen, S. (2001). Prognostic factors in lower limb joint arthroplasty. Key Engineering Materials, 192-195, 1007-1012.

Prognostic factors in lower limb joint arthroplasty. / Giannini, S.; Catani, Fabio; Ensini, A.; Cucca, G.; Bragonzoni, L.; Toksvig-Larsen, S.

In: Key Engineering Materials, Vol. 192-195, 2001, p. 1007-1012.

Research output: Contribution to journalArticle

Giannini, S, Catani, F, Ensini, A, Cucca, G, Bragonzoni, L & Toksvig-Larsen, S 2001, 'Prognostic factors in lower limb joint arthroplasty', Key Engineering Materials, vol. 192-195, pp. 1007-1012.
Giannini S, Catani F, Ensini A, Cucca G, Bragonzoni L, Toksvig-Larsen S. Prognostic factors in lower limb joint arthroplasty. Key Engineering Materials. 2001;192-195:1007-1012.
Giannini, S. ; Catani, Fabio ; Ensini, A. ; Cucca, G. ; Bragonzoni, L. ; Toksvig-Larsen, S. / Prognostic factors in lower limb joint arthroplasty. In: Key Engineering Materials. 2001 ; Vol. 192-195. pp. 1007-1012.
@article{fe4e53e760b04638a8a5c1470e766735,
title = "Prognostic factors in lower limb joint arthroplasty",
abstract = "A study was carried out to determine the influence of prosthesis design on fixation and to detect patients at high risk of mechanical aseptic loosening. The migration of implant in-vivo was quantified. Subsidence of hip arthroplasty was not found while the greater displacement was found in the tip of the stem.",
author = "S. Giannini and Fabio Catani and A. Ensini and G. Cucca and L. Bragonzoni and S. Toksvig-Larsen",
year = "2001",
language = "English",
volume = "192-195",
pages = "1007--1012",
journal = "Key Engineering Materials",
issn = "1013-9826",
publisher = "Trans Tech Publications",

}

TY - JOUR

T1 - Prognostic factors in lower limb joint arthroplasty

AU - Giannini, S.

AU - Catani, Fabio

AU - Ensini, A.

AU - Cucca, G.

AU - Bragonzoni, L.

AU - Toksvig-Larsen, S.

PY - 2001

Y1 - 2001

N2 - A study was carried out to determine the influence of prosthesis design on fixation and to detect patients at high risk of mechanical aseptic loosening. The migration of implant in-vivo was quantified. Subsidence of hip arthroplasty was not found while the greater displacement was found in the tip of the stem.

AB - A study was carried out to determine the influence of prosthesis design on fixation and to detect patients at high risk of mechanical aseptic loosening. The migration of implant in-vivo was quantified. Subsidence of hip arthroplasty was not found while the greater displacement was found in the tip of the stem.

UR - http://www.scopus.com/inward/record.url?scp=0035148263&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0035148263&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0035148263

VL - 192-195

SP - 1007

EP - 1012

JO - Key Engineering Materials

JF - Key Engineering Materials

SN - 1013-9826

ER -