Protein phosphorylation stoichiometry by simultaneous ICP-QMS determination of phosphorus and sulfur oxide ions: A multivariate optimization of plasma operating conditions

Domenico Ciavardelli, Paolo Sacchetta, Giorgio Federici, Carmine Di Ilio, Andrea Urbani

Research output: Contribution to journalArticle

Abstract

Molecular mass spectrometry (MS) analysis of protein phosphorylation is partially limited by the molecular specie specificity of the analytical responses that might impair both qualitative and quantitative performances. Elemental MS, such as inductively coupled plasma mass spectrometry (ICP-MS) can overcome these drawbacks; in fact, analytical performance is theoretically independent of the molecular structure of a target analyte naturally containing the elements of interest. Nevertheless, isobaric interferences derived from sample matrix and laboratory environment can hinder the quantitative determination of both phosphorus (P) and sulfur (S) as 31P+ and 32S+ by inductively coupled plasma quadrupole mass spectrometry (ICP-QMS) under standard plasma conditions. These interferences may be overcome by quantifying P and S as oxide ions 31P16O+ and 32S16O+, respectively. In this study, we present a systematic investigation on the effect of plasma instrumental conditions on the oxide ion responses by a design of experiment approach for the simultaneous ICP-QMS determination of P and S (31P16O+ and 32S16O+, respectively) in protein samples without the use of dynamic reaction, collision reaction cells or pre-addition of oxygen as reactant gas in the torch. The proposed method was evaluated in terms of limit of detection, limit of quantification, linearity, repeatability, and trueness. Moreover, detection and quantification capabilities of the optimized method were compared to the standard plasma mode for determination of 31P+ and 34S+. Spectral and non-spectral interferences affecting the quantification of 31P+, 31P16O+ and 32S16O+ were also studied. The suitability of inorganic elemental standards for P and S quantification in proteins was assessed. The method was applied to quantify the phosphorylation stoichiometry of commercially available caseins (bovine β-casein, native and dephosphorylated α-casein) and results were confirmed by Matrix Assisted Laser Desorption Ionization Time of Flight MS analysis. We demonstrate that ICP-QMS, by quantifying P and S as oxide ions, was able to accurately calculate the degree of phosphorylation of β-casein and α-casein and to detect specific partial enzymatic dephosphorylation. The collected results might lead to further development of ICP-QMS interfaces optimized for protein phosphorylation studies and for proteomics investigations.

Original languageEnglish
Pages (from-to)1513-1525
Number of pages13
JournalTalanta
Volume80
Issue number4
DOIs
Publication statusPublished - Feb 15 2010

Keywords

  • ICP-MS
  • MALDI-TOF-MS
  • Mass spectrometry
  • Phosphorylation
  • Proteomics

ASJC Scopus subject areas

  • Chemistry(all)

Fingerprint Dive into the research topics of 'Protein phosphorylation stoichiometry by simultaneous ICP-QMS determination of phosphorus and sulfur oxide ions: A multivariate optimization of plasma operating conditions'. Together they form a unique fingerprint.