Radiation dose and diagnostic accuracy of multidetector computed tomography for the detection of significant coronary artery stenoses

A meta-analysis

Gianluca Pontone, Daniele Andreini, Antonio L. Bartorelli, Erika Bertella, Saima Mushtaq, Andrea Annoni, Alberto Formenti, Luisa Chiappa, Sarah Cortinovis, Andrea Baggiano, Edoardo Conte, Francesca Bovis, Fabrizio Veglia, Claudia Foti, Giovanni Ballerini, Cesare Fiorentini, Mauro Pepi

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

We conducted a meta-analysis evaluating the critical ratio between effective radiation dose (ED), feasibility (Fe) and diagnostic accuracy (Ac) of multidetector computed tomography (MDCT) for the detection of significant coronary artery disease. By using our predetermined criteria, we selected human studies published in English in which the ED and raw data of Ac vs. invasive coronary angiography in a segment based model were specified. Data from 31 studies including 3661 patients (mean age 61.9 ± 4.5 years, heart rate 62.5 ± 6.7 bpm) and 50,236 coronary artery segments were analysed and are reported. Overall, Fe, sensitivity, specificity, negative predictive value, positive predictive value, Ac and ED were 95%, 90%, 96%, 99%, 69%, 95% and 10.4 ± 5.4 mSv, respectively. Multivariate analysis showed that prospective ECG-gating (- 8.8 mSv CI95% - 13.4 to - 4.3 mSv, p = 0.001), dual-source (- 3.7 mSv CI95% - 7.9 to 0 mSv, p = 0.05) and BMI-adapted scanning protocols (- 4.5 mSv CI95% - 8.7 to - 2.7 mSv, p = 0.03) were independent predictors of ED reduction. In patients with low heart rate, the best compromise between ED, Fe and Ac (2.5 mSv, 97% and 98%, respectively) was obtained combining prospective ECG-gating and BMI-adapted scanning protocols, while in patients with high heart rate the strategy associated with the best results (10 mSv, 98% and 97%, respectively) was the use of dual-source MDCT with retrospective ECG gating and modulation dose. In conclusion, careful selection of CT scanning protocols according to the patient's characteristics is critical for keeping the radiation exposure "as low as reasonably achievable" (ALARA) without impairing Fe and Ac.

Original languageEnglish
Pages (from-to)155-164
Number of pages10
JournalInternational Journal of Cardiology
Volume160
Issue number3
DOIs
Publication statusPublished - Oct 18 2012

Fingerprint

Multidetector Computed Tomography
Coronary Stenosis
Meta-Analysis
Radiation
Electrocardiography
Heart Rate
Coronary Angiography
Coronary Artery Disease
Coronary Vessels
Multivariate Analysis
Sensitivity and Specificity

Keywords

  • Accuracy
  • Computed tomography
  • Coronary artery disease
  • Feasibility
  • Radiation exposure

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Radiation dose and diagnostic accuracy of multidetector computed tomography for the detection of significant coronary artery stenoses : A meta-analysis. / Pontone, Gianluca; Andreini, Daniele; Bartorelli, Antonio L.; Bertella, Erika; Mushtaq, Saima; Annoni, Andrea; Formenti, Alberto; Chiappa, Luisa; Cortinovis, Sarah; Baggiano, Andrea; Conte, Edoardo; Bovis, Francesca; Veglia, Fabrizio; Foti, Claudia; Ballerini, Giovanni; Fiorentini, Cesare; Pepi, Mauro.

In: International Journal of Cardiology, Vol. 160, No. 3, 18.10.2012, p. 155-164.

Research output: Contribution to journalArticle

@article{ad524432a7dd4a01b4df5d7660e5a6dd,
title = "Radiation dose and diagnostic accuracy of multidetector computed tomography for the detection of significant coronary artery stenoses: A meta-analysis",
abstract = "We conducted a meta-analysis evaluating the critical ratio between effective radiation dose (ED), feasibility (Fe) and diagnostic accuracy (Ac) of multidetector computed tomography (MDCT) for the detection of significant coronary artery disease. By using our predetermined criteria, we selected human studies published in English in which the ED and raw data of Ac vs. invasive coronary angiography in a segment based model were specified. Data from 31 studies including 3661 patients (mean age 61.9 ± 4.5 years, heart rate 62.5 ± 6.7 bpm) and 50,236 coronary artery segments were analysed and are reported. Overall, Fe, sensitivity, specificity, negative predictive value, positive predictive value, Ac and ED were 95{\%}, 90{\%}, 96{\%}, 99{\%}, 69{\%}, 95{\%} and 10.4 ± 5.4 mSv, respectively. Multivariate analysis showed that prospective ECG-gating (- 8.8 mSv CI95{\%} - 13.4 to - 4.3 mSv, p = 0.001), dual-source (- 3.7 mSv CI95{\%} - 7.9 to 0 mSv, p = 0.05) and BMI-adapted scanning protocols (- 4.5 mSv CI95{\%} - 8.7 to - 2.7 mSv, p = 0.03) were independent predictors of ED reduction. In patients with low heart rate, the best compromise between ED, Fe and Ac (2.5 mSv, 97{\%} and 98{\%}, respectively) was obtained combining prospective ECG-gating and BMI-adapted scanning protocols, while in patients with high heart rate the strategy associated with the best results (10 mSv, 98{\%} and 97{\%}, respectively) was the use of dual-source MDCT with retrospective ECG gating and modulation dose. In conclusion, careful selection of CT scanning protocols according to the patient's characteristics is critical for keeping the radiation exposure {"}as low as reasonably achievable{"} (ALARA) without impairing Fe and Ac.",
keywords = "Accuracy, Computed tomography, Coronary artery disease, Feasibility, Radiation exposure",
author = "Gianluca Pontone and Daniele Andreini and Bartorelli, {Antonio L.} and Erika Bertella and Saima Mushtaq and Andrea Annoni and Alberto Formenti and Luisa Chiappa and Sarah Cortinovis and Andrea Baggiano and Edoardo Conte and Francesca Bovis and Fabrizio Veglia and Claudia Foti and Giovanni Ballerini and Cesare Fiorentini and Mauro Pepi",
year = "2012",
month = "10",
day = "18",
doi = "10.1016/j.ijcard.2011.08.854",
language = "English",
volume = "160",
pages = "155--164",
journal = "International Journal of Cardiology",
issn = "0167-5273",
publisher = "Elsevier Ireland Ltd",
number = "3",

}

TY - JOUR

T1 - Radiation dose and diagnostic accuracy of multidetector computed tomography for the detection of significant coronary artery stenoses

T2 - A meta-analysis

AU - Pontone, Gianluca

AU - Andreini, Daniele

AU - Bartorelli, Antonio L.

AU - Bertella, Erika

AU - Mushtaq, Saima

AU - Annoni, Andrea

AU - Formenti, Alberto

AU - Chiappa, Luisa

AU - Cortinovis, Sarah

AU - Baggiano, Andrea

AU - Conte, Edoardo

AU - Bovis, Francesca

AU - Veglia, Fabrizio

AU - Foti, Claudia

AU - Ballerini, Giovanni

AU - Fiorentini, Cesare

AU - Pepi, Mauro

PY - 2012/10/18

Y1 - 2012/10/18

N2 - We conducted a meta-analysis evaluating the critical ratio between effective radiation dose (ED), feasibility (Fe) and diagnostic accuracy (Ac) of multidetector computed tomography (MDCT) for the detection of significant coronary artery disease. By using our predetermined criteria, we selected human studies published in English in which the ED and raw data of Ac vs. invasive coronary angiography in a segment based model were specified. Data from 31 studies including 3661 patients (mean age 61.9 ± 4.5 years, heart rate 62.5 ± 6.7 bpm) and 50,236 coronary artery segments were analysed and are reported. Overall, Fe, sensitivity, specificity, negative predictive value, positive predictive value, Ac and ED were 95%, 90%, 96%, 99%, 69%, 95% and 10.4 ± 5.4 mSv, respectively. Multivariate analysis showed that prospective ECG-gating (- 8.8 mSv CI95% - 13.4 to - 4.3 mSv, p = 0.001), dual-source (- 3.7 mSv CI95% - 7.9 to 0 mSv, p = 0.05) and BMI-adapted scanning protocols (- 4.5 mSv CI95% - 8.7 to - 2.7 mSv, p = 0.03) were independent predictors of ED reduction. In patients with low heart rate, the best compromise between ED, Fe and Ac (2.5 mSv, 97% and 98%, respectively) was obtained combining prospective ECG-gating and BMI-adapted scanning protocols, while in patients with high heart rate the strategy associated with the best results (10 mSv, 98% and 97%, respectively) was the use of dual-source MDCT with retrospective ECG gating and modulation dose. In conclusion, careful selection of CT scanning protocols according to the patient's characteristics is critical for keeping the radiation exposure "as low as reasonably achievable" (ALARA) without impairing Fe and Ac.

AB - We conducted a meta-analysis evaluating the critical ratio between effective radiation dose (ED), feasibility (Fe) and diagnostic accuracy (Ac) of multidetector computed tomography (MDCT) for the detection of significant coronary artery disease. By using our predetermined criteria, we selected human studies published in English in which the ED and raw data of Ac vs. invasive coronary angiography in a segment based model were specified. Data from 31 studies including 3661 patients (mean age 61.9 ± 4.5 years, heart rate 62.5 ± 6.7 bpm) and 50,236 coronary artery segments were analysed and are reported. Overall, Fe, sensitivity, specificity, negative predictive value, positive predictive value, Ac and ED were 95%, 90%, 96%, 99%, 69%, 95% and 10.4 ± 5.4 mSv, respectively. Multivariate analysis showed that prospective ECG-gating (- 8.8 mSv CI95% - 13.4 to - 4.3 mSv, p = 0.001), dual-source (- 3.7 mSv CI95% - 7.9 to 0 mSv, p = 0.05) and BMI-adapted scanning protocols (- 4.5 mSv CI95% - 8.7 to - 2.7 mSv, p = 0.03) were independent predictors of ED reduction. In patients with low heart rate, the best compromise between ED, Fe and Ac (2.5 mSv, 97% and 98%, respectively) was obtained combining prospective ECG-gating and BMI-adapted scanning protocols, while in patients with high heart rate the strategy associated with the best results (10 mSv, 98% and 97%, respectively) was the use of dual-source MDCT with retrospective ECG gating and modulation dose. In conclusion, careful selection of CT scanning protocols according to the patient's characteristics is critical for keeping the radiation exposure "as low as reasonably achievable" (ALARA) without impairing Fe and Ac.

KW - Accuracy

KW - Computed tomography

KW - Coronary artery disease

KW - Feasibility

KW - Radiation exposure

UR - http://www.scopus.com/inward/record.url?scp=84880151061&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84880151061&partnerID=8YFLogxK

U2 - 10.1016/j.ijcard.2011.08.854

DO - 10.1016/j.ijcard.2011.08.854

M3 - Article

VL - 160

SP - 155

EP - 164

JO - International Journal of Cardiology

JF - International Journal of Cardiology

SN - 0167-5273

IS - 3

ER -