Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction

N M Uzunov, L Melendez-Alafort, M Bello, G Cicoria, F Zagni, L De Nardo, A Selva, L Mou, C Rossi-Alvarez, G Pupillo, G Di Domenico, L Uccelli, A Boschi, F Groppi, A Salvini, A Taibi, A Duatti, P Martini, M Pasquali, M LoriggiolaM Marengo, L Strada, S Manenti, A Rosato, J Esposito

Research output: Contribution to journalArticle

Abstract

Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotrons already available in the nuclear medicine departments of hospitals. The main motivation for such a study is in the framework of the research activities at the international level that have been conducted over the last few years to develop alternative production routes for the most widespread radioisotope used in medical imaging. The analysis of technetium isotopes and isomeric states (9xTc) present in the pertechnetate saline Na99mTcO4 solutions, obtained after the extraction/purification procedure, reveals radionuclidic purity levels basically in compliance with the limits recently issued by European Pharmacopoeia 9.3 (2018 Sodium pertechnetate (99mTc) injection 4801-3). Moreover, the impact of 9xTc contaminant nuclides on the final image quality is thoroughly evaluated, analyzing the emitted high-energy gamma rays and their influence on the image quality. The spatial resolution of images from cyclotron-produced 99mTc acquired with a mini-gamma camera was determined and compared with that obtained using technetium-99m solutions eluted from standard 99Mo/99mTc generators. The effect of the increased image background contribution due to Compton-scattered higher-energy gamma rays (E γ   >  200 keV), which could cause image-contrast deterioration, was also studied. It is concluded that, due to the high radionuclidic purity of cyclotron-produced 99mTc using 100Mo(p,2n)99mTc reaction at a proton beam energy in the range 15.7-19.4 MeV, the resulting image properties are well comparable with those from the generator-eluted 99mTc.

Original languageEnglish
Pages (from-to)185021
JournalPhysics in Medicine and Biology
Volume63
Issue number18
DOIs
Publication statusPublished - Sep 19 2018

Fingerprint

Cyclotrons
Technetium
Protons
Sodium Pertechnetate Tc 99m
Gamma Rays
Hospital Nuclear Medicine Departments
Pharmacopoeias
Gamma Cameras
Diagnostic Imaging
Sodium Chloride
Radioisotopes
Isotopes
Injections
Research

Cite this

Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction. / Uzunov, N M; Melendez-Alafort, L; Bello, M; Cicoria, G; Zagni, F; De Nardo, L; Selva, A; Mou, L; Rossi-Alvarez, C; Pupillo, G; Di Domenico, G; Uccelli, L; Boschi, A; Groppi, F; Salvini, A; Taibi, A; Duatti, A; Martini, P; Pasquali, M; Loriggiola, M; Marengo, M; Strada, L; Manenti, S; Rosato, A; Esposito, J.

In: Physics in Medicine and Biology, Vol. 63, No. 18, 19.09.2018, p. 185021.

Research output: Contribution to journalArticle

Uzunov, NM, Melendez-Alafort, L, Bello, M, Cicoria, G, Zagni, F, De Nardo, L, Selva, A, Mou, L, Rossi-Alvarez, C, Pupillo, G, Di Domenico, G, Uccelli, L, Boschi, A, Groppi, F, Salvini, A, Taibi, A, Duatti, A, Martini, P, Pasquali, M, Loriggiola, M, Marengo, M, Strada, L, Manenti, S, Rosato, A & Esposito, J 2018, 'Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction', Physics in Medicine and Biology, vol. 63, no. 18, pp. 185021. https://doi.org/10.1088/1361-6560/aadc88
Uzunov, N M ; Melendez-Alafort, L ; Bello, M ; Cicoria, G ; Zagni, F ; De Nardo, L ; Selva, A ; Mou, L ; Rossi-Alvarez, C ; Pupillo, G ; Di Domenico, G ; Uccelli, L ; Boschi, A ; Groppi, F ; Salvini, A ; Taibi, A ; Duatti, A ; Martini, P ; Pasquali, M ; Loriggiola, M ; Marengo, M ; Strada, L ; Manenti, S ; Rosato, A ; Esposito, J. / Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction. In: Physics in Medicine and Biology. 2018 ; Vol. 63, No. 18. pp. 185021.
@article{a3d35c15faca47fa93cb0be45fcafa68,
title = "Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction",
abstract = "Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotrons already available in the nuclear medicine departments of hospitals. The main motivation for such a study is in the framework of the research activities at the international level that have been conducted over the last few years to develop alternative production routes for the most widespread radioisotope used in medical imaging. The analysis of technetium isotopes and isomeric states (9xTc) present in the pertechnetate saline Na99mTcO4 solutions, obtained after the extraction/purification procedure, reveals radionuclidic purity levels basically in compliance with the limits recently issued by European Pharmacopoeia 9.3 (2018 Sodium pertechnetate (99mTc) injection 4801-3). Moreover, the impact of 9xTc contaminant nuclides on the final image quality is thoroughly evaluated, analyzing the emitted high-energy gamma rays and their influence on the image quality. The spatial resolution of images from cyclotron-produced 99mTc acquired with a mini-gamma camera was determined and compared with that obtained using technetium-99m solutions eluted from standard 99Mo/99mTc generators. The effect of the increased image background contribution due to Compton-scattered higher-energy gamma rays (E γ   >  200 keV), which could cause image-contrast deterioration, was also studied. It is concluded that, due to the high radionuclidic purity of cyclotron-produced 99mTc using 100Mo(p,2n)99mTc reaction at a proton beam energy in the range 15.7-19.4 MeV, the resulting image properties are well comparable with those from the generator-eluted 99mTc.",
author = "Uzunov, {N M} and L Melendez-Alafort and M Bello and G Cicoria and F Zagni and {De Nardo}, L and A Selva and L Mou and C Rossi-Alvarez and G Pupillo and {Di Domenico}, G and L Uccelli and A Boschi and F Groppi and A Salvini and A Taibi and A Duatti and P Martini and M Pasquali and M Loriggiola and M Marengo and L Strada and S Manenti and A Rosato and J Esposito",
year = "2018",
month = "9",
day = "19",
doi = "10.1088/1361-6560/aadc88",
language = "English",
volume = "63",
pages = "185021",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "18",

}

TY - JOUR

T1 - Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction

AU - Uzunov, N M

AU - Melendez-Alafort, L

AU - Bello, M

AU - Cicoria, G

AU - Zagni, F

AU - De Nardo, L

AU - Selva, A

AU - Mou, L

AU - Rossi-Alvarez, C

AU - Pupillo, G

AU - Di Domenico, G

AU - Uccelli, L

AU - Boschi, A

AU - Groppi, F

AU - Salvini, A

AU - Taibi, A

AU - Duatti, A

AU - Martini, P

AU - Pasquali, M

AU - Loriggiola, M

AU - Marengo, M

AU - Strada, L

AU - Manenti, S

AU - Rosato, A

AU - Esposito, J

PY - 2018/9/19

Y1 - 2018/9/19

N2 - Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotrons already available in the nuclear medicine departments of hospitals. The main motivation for such a study is in the framework of the research activities at the international level that have been conducted over the last few years to develop alternative production routes for the most widespread radioisotope used in medical imaging. The analysis of technetium isotopes and isomeric states (9xTc) present in the pertechnetate saline Na99mTcO4 solutions, obtained after the extraction/purification procedure, reveals radionuclidic purity levels basically in compliance with the limits recently issued by European Pharmacopoeia 9.3 (2018 Sodium pertechnetate (99mTc) injection 4801-3). Moreover, the impact of 9xTc contaminant nuclides on the final image quality is thoroughly evaluated, analyzing the emitted high-energy gamma rays and their influence on the image quality. The spatial resolution of images from cyclotron-produced 99mTc acquired with a mini-gamma camera was determined and compared with that obtained using technetium-99m solutions eluted from standard 99Mo/99mTc generators. The effect of the increased image background contribution due to Compton-scattered higher-energy gamma rays (E γ   >  200 keV), which could cause image-contrast deterioration, was also studied. It is concluded that, due to the high radionuclidic purity of cyclotron-produced 99mTc using 100Mo(p,2n)99mTc reaction at a proton beam energy in the range 15.7-19.4 MeV, the resulting image properties are well comparable with those from the generator-eluted 99mTc.

AB - Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15-20 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotrons already available in the nuclear medicine departments of hospitals. The main motivation for such a study is in the framework of the research activities at the international level that have been conducted over the last few years to develop alternative production routes for the most widespread radioisotope used in medical imaging. The analysis of technetium isotopes and isomeric states (9xTc) present in the pertechnetate saline Na99mTcO4 solutions, obtained after the extraction/purification procedure, reveals radionuclidic purity levels basically in compliance with the limits recently issued by European Pharmacopoeia 9.3 (2018 Sodium pertechnetate (99mTc) injection 4801-3). Moreover, the impact of 9xTc contaminant nuclides on the final image quality is thoroughly evaluated, analyzing the emitted high-energy gamma rays and their influence on the image quality. The spatial resolution of images from cyclotron-produced 99mTc acquired with a mini-gamma camera was determined and compared with that obtained using technetium-99m solutions eluted from standard 99Mo/99mTc generators. The effect of the increased image background contribution due to Compton-scattered higher-energy gamma rays (E γ   >  200 keV), which could cause image-contrast deterioration, was also studied. It is concluded that, due to the high radionuclidic purity of cyclotron-produced 99mTc using 100Mo(p,2n)99mTc reaction at a proton beam energy in the range 15.7-19.4 MeV, the resulting image properties are well comparable with those from the generator-eluted 99mTc.

U2 - 10.1088/1361-6560/aadc88

DO - 10.1088/1361-6560/aadc88

M3 - Article

C2 - 30229740

VL - 63

SP - 185021

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 18

ER -