TY - JOUR
T1 - Rationale and design of fire and ice
T2 - A multicenter randomized trial comparing efficacy and safety of pulmonary vein isolation using a cryoballoon versus radiofrequency ablation with 3d-reconstruction
AU - Fürnkranz, Alexander
AU - Brugada, Josep
AU - Albenque, Jean Paul
AU - Tondo, Claudio
AU - Bestehorn, Kurt
AU - Wegscheider, Karl
AU - Ouyang, Feifan
AU - Kuck, Karl Heinz
PY - 2014/12/1
Y1 - 2014/12/1
N2 - Rationale and Design of Fire and Ice Background Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia imposing substantial morbidity and mortality. Catheter-based pulmonary vein isolation (PVI) using radiofrequency current (RFC) has become a standard treatment for drug-resistant and symptomatic paroxysmal AF (PAF). In recent years, the cryoballoon-based technique is increasingly used as a promising alternative with a short learning curve. Methods The FIRE AND ICE trial is a prospective, randomized, controlled, open, blinded outcome assessment, noninferiority trial comparing cryoballoon-, and RFC-based PVI. Patients with drug-resistant PAF will be randomized in a 1:1 matrix in multiple European centers. The primary hypothesis is that cryoballoon ablation is not inferior to RFC ablation using 3-dimensional mapping with respect to clinical efficacy. The primary endpoint is defined as the time to first documented clinical failure, including: (1) recurrence of AF; (2) atrial flutter or atrial tachycardia; (3) prescription of class I or III antiarrhythmic drugs; or (4) re-ablation, whichever comes first, following a blanking period of 3 months after the index ablation procedure. The primary safety endpoint is a composite of death, stroke/transient ischemic attack, cardiac arrhythmias (apart from AF recurrence) causally related to the therapeutic intervention, and procedure-related serious adverse events. Conclusion The FIRE AND ICE trial compares 2 different technologies to perform catheter ablation of PAF with respect to efficacy and safety. It aims at providing objective data to guide selection and usage of ablation catheters in the treatment of AF.
AB - Rationale and Design of Fire and Ice Background Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia imposing substantial morbidity and mortality. Catheter-based pulmonary vein isolation (PVI) using radiofrequency current (RFC) has become a standard treatment for drug-resistant and symptomatic paroxysmal AF (PAF). In recent years, the cryoballoon-based technique is increasingly used as a promising alternative with a short learning curve. Methods The FIRE AND ICE trial is a prospective, randomized, controlled, open, blinded outcome assessment, noninferiority trial comparing cryoballoon-, and RFC-based PVI. Patients with drug-resistant PAF will be randomized in a 1:1 matrix in multiple European centers. The primary hypothesis is that cryoballoon ablation is not inferior to RFC ablation using 3-dimensional mapping with respect to clinical efficacy. The primary endpoint is defined as the time to first documented clinical failure, including: (1) recurrence of AF; (2) atrial flutter or atrial tachycardia; (3) prescription of class I or III antiarrhythmic drugs; or (4) re-ablation, whichever comes first, following a blanking period of 3 months after the index ablation procedure. The primary safety endpoint is a composite of death, stroke/transient ischemic attack, cardiac arrhythmias (apart from AF recurrence) causally related to the therapeutic intervention, and procedure-related serious adverse events. Conclusion The FIRE AND ICE trial compares 2 different technologies to perform catheter ablation of PAF with respect to efficacy and safety. It aims at providing objective data to guide selection and usage of ablation catheters in the treatment of AF.
KW - atrial fibrillation
KW - catheter ablation
KW - cryoballoon
KW - electrophysiology
KW - radiofrequency ablation
UR - http://www.scopus.com/inward/record.url?scp=84926385045&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84926385045&partnerID=8YFLogxK
U2 - 10.1111/jce.12529
DO - 10.1111/jce.12529
M3 - Article
C2 - 25146732
AN - SCOPUS:84926385045
VL - 25
SP - 1314
EP - 1320
JO - Journal of Cardiovascular Electrophysiology
JF - Journal of Cardiovascular Electrophysiology
SN - 1045-3873
IS - 12