Reliability of clinical outcome measures in Charcot-Marie-Tooth disease

Research output: Contribution to journalArticle

Abstract

We assessed inter- and intra-rater reliability of outcome measures in Charcot-Marie-Tooth disease (CMT) patients. In 40 CMT patients, we assessed reliability of Overall Neuropathy Limitations Scale (ONLS), 10-m timed walk (T10MW), 9-hole-peg test (9-HPT), maximal voluntary isometric contraction (MVIC) of arm (elbow flexion, hand-grip, and three-point pinch) and leg (knee extension, foot dorsiflexion/plantar flexion). Reliability was substantial for ONLS, excellent for T10MW and 9-HPT. For MVIC, inter and intra-rater reliability was excellent for hand contractions; for leg contractions, intra-rater agreement was moderate to substantial, whereas inter-rater agreement was poor. An ad hoc device was produced to immobilize the foot and MVIC reliability was re-assessed in 26 CMT patients, resulting in excellent inter-rater and intra-rater reliability for foot dorsiflexion, and clear inter-rater improvement for foot plantar flexion. All outcome measures appear adequate for CMT assessment. Use of an immobilization device improves foot MVIC reliability, preventing biased findings in patients with greater strength.

Original languageEnglish
Pages (from-to)19-26
Number of pages8
JournalNeuromuscular Disorders
Volume18
Issue number1
DOIs
Publication statusPublished - Jan 1 2008

Keywords

  • Charcot-Marie-Tooth disease
  • Outcome measures
  • Randomised clinical trial
  • Reliability

ASJC Scopus subject areas

  • Clinical Neurology
  • Pediatrics, Perinatology, and Child Health
  • Genetics(clinical)
  • Neurology

Fingerprint Dive into the research topics of 'Reliability of clinical outcome measures in Charcot-Marie-Tooth disease'. Together they form a unique fingerprint.

  • Cite this