TY - JOUR
T1 - Renal Function Assessment Gap in Clinical Practice
T2 - An Awkward Truth
AU - Trevisani, Francesco
AU - Di Marco, Federico
AU - Capitanio, Umberto
AU - Larcher, Alessandro
AU - Bettiga, Arianna
AU - Dosio, Flaviano
AU - Ghidini, Michele
AU - Del Conte, Gianluca
AU - Vago, Riccardo
AU - Cinque, Alessandra
AU - Gianolli, Luigi
AU - Salonia, Andrea
AU - Briganti, Alberto
AU - Luis-Lima, Sergio
AU - Negrín-Mena, Natalia
AU - Montorsi, Francesco
AU - Porrini, Esteban
PY - 2020/3/1
Y1 - 2020/3/1
N2 - Introduction: An accurate assessment of renal function is needed in the majority of clinical settings. Unfortunately, the most used estimated glomerular filtration rate (eGFR) formulas are affected by significant errors in comparison to gold standards methods of measured GFR (mGFR). Objective: The objective of the study is to determine the extent of the error of eGFR formulas compared to the mGFR in different specific clinical settings. Methods: A total retrospectively consecutive cohort of 1,320 patients (pts) enrolled in 2 different European Hospitals (Center 1: 470 pts; Center 2: 850 pts) was collected in order to compare the most common eGFR formulas used by physicians with the most widespread mGFR methods in daily clinical practice (Iohexol Plasma Clearance -Center 1 [mGFR-iox] and Renal Scintigraphy -Center 2 [mGFR-scnt]). The study cohort was composed by urological, oncological, and nephrological pts. The agreement between eGFR and mGFR was evaluated using bias (as median of difference), precision (as interquartile range of difference) accuracy (as P30), and total deviation index. Results: The most accurate eGFR formula in the comparison with gold standard method (Iohexol plasma clearance) in Center 1 was represented by s-creatinine and cystatin C combined Chronic Kidney Disease-Epidemiology Collaboration-cr-cy, even though the P30 is reduced (84%) under the threshold of 60 mL/min/1.73 m2. Similar results were found in Center 2, with a wider discrepancy between mGFR-scnt and eGFR formulas due to the minor accuracy of the nuclear tool in respect to the mGFR-iox. Conclusions: The loss of accuracy observed for the formulas at lower values of GFR suggests the mandatory use of gold standards methods as Iohexol Plasma Clearance to assess the correct status of renal function for critical cases. The center 2 showed lower levels of agreement between mGFR and eGFR suggesting that the errors are partially accounted for the Renal Scintigraphy technique too. In particular, we suggest the use of mGFR-iox in oncological urological and nephrological pts with an eGFR lower than 60 mL/min/1.73 m2.
AB - Introduction: An accurate assessment of renal function is needed in the majority of clinical settings. Unfortunately, the most used estimated glomerular filtration rate (eGFR) formulas are affected by significant errors in comparison to gold standards methods of measured GFR (mGFR). Objective: The objective of the study is to determine the extent of the error of eGFR formulas compared to the mGFR in different specific clinical settings. Methods: A total retrospectively consecutive cohort of 1,320 patients (pts) enrolled in 2 different European Hospitals (Center 1: 470 pts; Center 2: 850 pts) was collected in order to compare the most common eGFR formulas used by physicians with the most widespread mGFR methods in daily clinical practice (Iohexol Plasma Clearance -Center 1 [mGFR-iox] and Renal Scintigraphy -Center 2 [mGFR-scnt]). The study cohort was composed by urological, oncological, and nephrological pts. The agreement between eGFR and mGFR was evaluated using bias (as median of difference), precision (as interquartile range of difference) accuracy (as P30), and total deviation index. Results: The most accurate eGFR formula in the comparison with gold standard method (Iohexol plasma clearance) in Center 1 was represented by s-creatinine and cystatin C combined Chronic Kidney Disease-Epidemiology Collaboration-cr-cy, even though the P30 is reduced (84%) under the threshold of 60 mL/min/1.73 m2. Similar results were found in Center 2, with a wider discrepancy between mGFR-scnt and eGFR formulas due to the minor accuracy of the nuclear tool in respect to the mGFR-iox. Conclusions: The loss of accuracy observed for the formulas at lower values of GFR suggests the mandatory use of gold standards methods as Iohexol Plasma Clearance to assess the correct status of renal function for critical cases. The center 2 showed lower levels of agreement between mGFR and eGFR suggesting that the errors are partially accounted for the Renal Scintigraphy technique too. In particular, we suggest the use of mGFR-iox in oncological urological and nephrological pts with an eGFR lower than 60 mL/min/1.73 m2.
KW - Cystatin C
KW - Estimated glomerular filtration rate
KW - Glomerular filtration rate
KW - Measured glomerular filtration rate
KW - Renal function
KW - Renal measurement techniques
KW - Serum creatinine
UR - http://www.scopus.com/inward/record.url?scp=85078948874&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85078948874&partnerID=8YFLogxK
U2 - 10.1159/000504649
DO - 10.1159/000504649
M3 - Article
C2 - 31982867
AN - SCOPUS:85078948874
VL - 45
SP - 166
EP - 179
JO - Kidney and Blood Pressure Research
JF - Kidney and Blood Pressure Research
SN - 1420-4096
IS - 2
ER -