TY - JOUR
T1 - Repeatability and Reproducibility of Foveal Avascular Zone Area Measurement on Normal Eyes by Different Optical Coherence Tomography Angiography Instruments
AU - Pilotto, Elisabetta
AU - Frizziero, Luisa
AU - Crepaldi, Anna
AU - Della Dora, Enrico
AU - Deganello, Davide
AU - Longhin, Evelyn
AU - Convento, Enrica
AU - Parrozzani, Raffaele
AU - Midena, Edoardo
PY - 2018/5/1
Y1 - 2018/5/1
N2 - Purpose: To compare the foveal avascular zone (FAZ) area measurements produced by different optical coherence tomography angiography (OCTA). Methods: Healthy enrolled volunteers underwent OCTA using 2 different devices: Spectralis HRA+OCTA (Heidelberg Engineering, Heidelberg, Germany) and RS-3000 Advance (Nidek, Gamagori, Japan). Two graders measured FAZ in both superficial (SCP) and deep (DCP) retinal capillary plexuses. The SCP and DCP en face images were visualized automatically segmenting 2 separate slabs defined by the arbitrary segmentation lines created by the software of each OCT device. One grader repeated each measure twice. Results: Fifty-nine eyes were included. The mean FAZ was 0.33 ± 0.09 mm2 at the SCP and 0.57 ± 0.17 mm2 at the DCP measured with RS-3000 versus 0.30 ± 0.08 and 0.35 ± 0.08 mm2, respectively, measured with Spectralis. The measurements of the 2 devices were significantly different (p < 0.0001). The intraoperator agreement was excellent at the SCP (intraclass correlation coefficient, ICC: 0.97 with Spectralis and 0.96 with RS-3000). At the DCP, it was good with Spectralis and fair with RS-3000 (ICC: 0.85 and 0.64, respectively). The interoperator agreement was excellent for Spectralis and good for RS-3000 at the SCP (ICC: 0.97 and 0.93, respectively). It was good at the DCP with both devices (ICC: 0.74 with RS-3000 and 0.81 with Spectralis). Conclusions: FAZ measurements obtained with different OCTA devices differ. These findings should be considered in follow-up studies of patients with retinal vascular diseases.
AB - Purpose: To compare the foveal avascular zone (FAZ) area measurements produced by different optical coherence tomography angiography (OCTA). Methods: Healthy enrolled volunteers underwent OCTA using 2 different devices: Spectralis HRA+OCTA (Heidelberg Engineering, Heidelberg, Germany) and RS-3000 Advance (Nidek, Gamagori, Japan). Two graders measured FAZ in both superficial (SCP) and deep (DCP) retinal capillary plexuses. The SCP and DCP en face images were visualized automatically segmenting 2 separate slabs defined by the arbitrary segmentation lines created by the software of each OCT device. One grader repeated each measure twice. Results: Fifty-nine eyes were included. The mean FAZ was 0.33 ± 0.09 mm2 at the SCP and 0.57 ± 0.17 mm2 at the DCP measured with RS-3000 versus 0.30 ± 0.08 and 0.35 ± 0.08 mm2, respectively, measured with Spectralis. The measurements of the 2 devices were significantly different (p < 0.0001). The intraoperator agreement was excellent at the SCP (intraclass correlation coefficient, ICC: 0.97 with Spectralis and 0.96 with RS-3000). At the DCP, it was good with Spectralis and fair with RS-3000 (ICC: 0.85 and 0.64, respectively). The interoperator agreement was excellent for Spectralis and good for RS-3000 at the SCP (ICC: 0.97 and 0.93, respectively). It was good at the DCP with both devices (ICC: 0.74 with RS-3000 and 0.81 with Spectralis). Conclusions: FAZ measurements obtained with different OCTA devices differ. These findings should be considered in follow-up studies of patients with retinal vascular diseases.
UR - http://www.scopus.com/inward/record.url?scp=85041525999&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85041525999&partnerID=8YFLogxK
U2 - 10.1159/000485463
DO - 10.1159/000485463
M3 - Article
C2 - 29421813
AN - SCOPUS:85041525999
VL - 59
SP - 206
EP - 211
JO - Ophthalmic Research
JF - Ophthalmic Research
SN - 0030-3747
IS - 4
ER -