Reproducibility and biases in high field brain diffusion MRI: An evaluation of acquisition and analysis variables

Nico Dario Papinutto, Francesca Maule, Jorge Jovicich

Research output: Contribution to journalArticlepeer-review

Abstract

Diffusion tensor imaging (DTI) of in-vivo human brain provides insights into white matter anatomical connectivity, but little is known about measurement difference biases and reliability of data obtained with last generation high field scanners (>3T) as function of MRI acquisition and analyses variables. Here we assess the impact of acquisition (voxel size: 1.8×1.8×1.8, 2×2×2 and 2.5×2.5×2.5mm3, b-value: 700, 1000 and 1300s/mm2) and analysis variables (within-session averaging and co-registration methods) on biases and test-retest reproducibility of some common tensor derived quantities like fractional anisotropy (FA), mean diffusivity (MD), axial and radial diffusivity in a group of healthy subjects at 4T in three regions: arcuate fasciculus, corpus callosum and cingulum. Averaging effects are also evaluated on a full-brain voxel based approach. The main results are: i) group FA and MD reproducibility errors across scan sessions are on average double of those found in within-session repetitions (≈1.3 %), regardless of acquisition protocol and region; ii) within-session averaging of two DTI acquisitions does not improve reproducibility of any of the quantities across sessions at the group level, regardless of acquisition protocol; iii) increasing voxel size biased MD, axial and radial diffusivities to higher values and FA to lower values; iv) increasing b-value biased all quantities to lower values, axial diffusivity showing the strongest effects; v) the two co-registration methods evaluated gave similar bias and reproducibility results. Altogether these results show that reproducibility of FA and MD is comparable to that found at lower fields, not significantly dependent on pre-processing and acquisition protocol manipulations, but that the specific choice of acquisition parameters can significantly bias the group measures of FA, MD, axial and radial diffusivities.

Original languageEnglish
Pages (from-to)827-839
Number of pages13
JournalMagnetic Resonance Imaging
Volume31
Issue number6
DOIs
Publication statusPublished - Jul 2013

Keywords

  • Biases
  • Diffusion tensor imaging
  • Fractional anisotropy
  • High field MRI
  • Mean diffusivity
  • Principal eigenvalues
  • Reproducibility

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging
  • Biomedical Engineering

Fingerprint Dive into the research topics of 'Reproducibility and biases in high field brain diffusion MRI: An evaluation of acquisition and analysis variables'. Together they form a unique fingerprint.

Cite this