T1 - Reproducibility of a semi-automatic method for 6-point vertebral morphometry in a multi-centre trial
AU - Guglielmi, Giuseppe
AU - Stoppino, Luca Pio
AU - Placentino, Maria Grazia
AU - D'Errico, Francesco
AU - Palmieri, Francesco
PY - 2009/1
Y1 - 2009/1
N2 - Purpose: To evaluate the reproducibility of a semi-automated system for vertebral morphometry (MorphoXpress) in a large multi-centre trial. Materials and methods: The study involved 132 clinicians (no radiologist) with different levels of experience across 20 osteo-centres in Italy. All have received training in using MorphoXpress. An expert radiologist was also involved providing data used as standard of reference. The test image originate from normal clinical activity and represent a variety of normal, under and over exposed films, indicating both normal anatomy and vertebral deformities. The image was represented twice to the clinicians in a random order. Using the software, the clinicians initially marked the midpoints of the upper and lower vertebrae to include as many of the vertebrae (T5-L4) as practical within each given image. MorphoXpress performs the localisation of all morphometric points based on statistical model-based vision system. Intra-operator as well inter-operator measurement of agreement was calculated using the coefficient of variation and the mean and standard deviation of the difference of two measurements to check their agreement. Results: The overall intra-operator mean differences in vertebral heights is 1.61 ± 4.27% (1 S.D.). The overall intra-operator coefficient of variation is 3.95%. The overall inter-operator mean differences in vertebral heights is 2.93 ± 5.38% (1 S.D.). The overall inter-operator coefficient of variation is 6.89%. Conclusions: The technology tested here can facilitate reproducible quantitative morphometry suitable for large studies of vertebral deformities.
AB - Purpose: To evaluate the reproducibility of a semi-automated system for vertebral morphometry (MorphoXpress) in a large multi-centre trial. Materials and methods: The study involved 132 clinicians (no radiologist) with different levels of experience across 20 osteo-centres in Italy. All have received training in using MorphoXpress. An expert radiologist was also involved providing data used as standard of reference. The test image originate from normal clinical activity and represent a variety of normal, under and over exposed films, indicating both normal anatomy and vertebral deformities. The image was represented twice to the clinicians in a random order. Using the software, the clinicians initially marked the midpoints of the upper and lower vertebrae to include as many of the vertebrae (T5-L4) as practical within each given image. MorphoXpress performs the localisation of all morphometric points based on statistical model-based vision system. Intra-operator as well inter-operator measurement of agreement was calculated using the coefficient of variation and the mean and standard deviation of the difference of two measurements to check their agreement. Results: The overall intra-operator mean differences in vertebral heights is 1.61 ± 4.27% (1 S.D.). The overall intra-operator coefficient of variation is 3.95%. The overall inter-operator mean differences in vertebral heights is 2.93 ± 5.38% (1 S.D.). The overall inter-operator coefficient of variation is 6.89%. Conclusions: The technology tested here can facilitate reproducible quantitative morphometry suitable for large studies of vertebral deformities.
KW - Model-based vision
KW - Osteoporosis
KW - Radiographs
KW - Spine
KW - Vertebral morphometry
UR - http://www.scopus.com/inward/record.url?scp=58149504648&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=58149504648&partnerID=8YFLogxK
U2 - 10.1016/j.ejrad.2007.09.040
DO - 10.1016/j.ejrad.2007.09.040
M3 - Article
C2 - 18078732
AN - SCOPUS:58149504648
VL - 69
SP - 173
EP - 178
JO - European Journal of Radiology
JF - European Journal of Radiology
SN - 0720-048X
IS - 1
ER -