TY - JOUR
T1 - Reproducibility of clinician-friendly physical performance measures in individuals with obesity
AU - Maffiuletti, Nicola A.
AU - Tringali, Gabriella
AU - Patrizi, Alessandra
AU - Agosti, Fiorenza
AU - Sartorio, Alessandro
PY - 2017/1/1
Y1 - 2017/1/1
N2 - Objective: To evaluate the reproducibility (reliability and agreement) of different physical performance measures in individuals with obesity. Methods: Forty subjects (20 men, 20 women), mean age 29 years, mean body mass index (BMI) 42 kg/m2 completed several clinician-friendly performancebased tests (walking, stair-climbing, sit-To-stand, static balance, flexibility and strength) on 2 different occasions (test-retest design). Intraclass correlation coefficients (reliability) and smallest detectable changes (agreement) were calculated for each outcome measure. Results: Intraclass correlation coefficients were relatively high (range 0.84-0.94) for all the performance-based measures (i.e. acceptable reliability). Smallest detectable changes were overall quite high and beyond the arbitrarily-defined minimal clinically important changes (i.e. poor agreement) for 3 out of 8 variables (sit-To-stand time, time-in-balance with eyes closed, and sit-And-reach distance). Conclusion: The clinician-friendly performance-based tests for individuals with obesity considered in this study appear legitimate for discriminative purposes, such as in cross-sectional studies. However, for longitudinal assessments (evaluative purposes), some measures should be used with greater caution due to limited agreement. Careful consideration should be given to the evaluation of physical performance in people with obesity, particularly in the context of conservative or surgical treatment for weight loss.
AB - Objective: To evaluate the reproducibility (reliability and agreement) of different physical performance measures in individuals with obesity. Methods: Forty subjects (20 men, 20 women), mean age 29 years, mean body mass index (BMI) 42 kg/m2 completed several clinician-friendly performancebased tests (walking, stair-climbing, sit-To-stand, static balance, flexibility and strength) on 2 different occasions (test-retest design). Intraclass correlation coefficients (reliability) and smallest detectable changes (agreement) were calculated for each outcome measure. Results: Intraclass correlation coefficients were relatively high (range 0.84-0.94) for all the performance-based measures (i.e. acceptable reliability). Smallest detectable changes were overall quite high and beyond the arbitrarily-defined minimal clinically important changes (i.e. poor agreement) for 3 out of 8 variables (sit-To-stand time, time-in-balance with eyes closed, and sit-And-reach distance). Conclusion: The clinician-friendly performance-based tests for individuals with obesity considered in this study appear legitimate for discriminative purposes, such as in cross-sectional studies. However, for longitudinal assessments (evaluative purposes), some measures should be used with greater caution due to limited agreement. Careful consideration should be given to the evaluation of physical performance in people with obesity, particularly in the context of conservative or surgical treatment for weight loss.
KW - Obesity
KW - Outcomes
KW - Physical performance
KW - Reproducibility
UR - http://www.scopus.com/inward/record.url?scp=85028700138&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85028700138&partnerID=8YFLogxK
U2 - 10.2340/16501977-2263
DO - 10.2340/16501977-2263
M3 - Article
AN - SCOPUS:85028700138
VL - 49
SP - 677
EP - 681
JO - Journal of Rehabilitation Medicine
JF - Journal of Rehabilitation Medicine
SN - 1650-1977
IS - 8
ER -