Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET

L. Livieratos, L. Stegger, P. M. Bloomfield, K. Schafers, D. L. Bailey, P. G. Camici

Research output: Contribution to journalArticle

107 Citations (Scopus)

Abstract

High-resolution cardiac PET imaging with emphasis on quantification would benefit from eliminating the problem of respiratory movement during data acquisition. Respiratory gating on the basis of list-mode data has been employed previously as one approach to reduce motion effects. However, it results in poor count statistics with degradation of image quality. This work reports on the implementation of a technique to correct for respiratory motion in the area of the heart at no extra cost for count statistics and with the potential to maintain ECG gating, based on rigid-body transformations on list-mode data event-by-event. A motion-corrected data set is obtained by assigning, after pre-correction for detector efficiency and photon attenuation, individual lines-of-response to new detector pairs with consideration of respiratory motion. Parameters of respiratory motion are obtained from a series of gated image sets by means of image registration. Respiration is recorded simultaneously with the list-mode data using an inductive respiration monitor with an elasticized belt at chest level. The accuracy of the technique was assessed with point-source data showing a good correlation between measured and true transformations. The technique was applied on phantom data with simulated respiratory motion, showing successful recovery of tracer distribution and contrast on the motion-corrected images, and on patient data with C 15O and 18FDG. Quantitative assessment of preliminary C15O patient data showed improvement in the recovery coefficient at the centre of the left ventricle.

Original languageEnglish
Pages (from-to)3313-3322
Number of pages10
JournalPhysics in Medicine and Biology
Volume50
Issue number14
DOIs
Publication statusPublished - Jul 21 2005

Fingerprint

rigid structures
lists
projection
Statistics
Detectors
Recovery
Image registration
Bioelectric potentials
Electrocardiography
Image quality
Data acquisition
Photons
Imaging techniques
Degradation
respiration
Respiration
Costs
recovery
statistics
Information Storage and Retrieval

ASJC Scopus subject areas

  • Biomedical Engineering
  • Physics and Astronomy (miscellaneous)
  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET. / Livieratos, L.; Stegger, L.; Bloomfield, P. M.; Schafers, K.; Bailey, D. L.; Camici, P. G.

In: Physics in Medicine and Biology, Vol. 50, No. 14, 21.07.2005, p. 3313-3322.

Research output: Contribution to journalArticle

Livieratos, L. ; Stegger, L. ; Bloomfield, P. M. ; Schafers, K. ; Bailey, D. L. ; Camici, P. G. / Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET. In: Physics in Medicine and Biology. 2005 ; Vol. 50, No. 14. pp. 3313-3322.
@article{7822a6d519ba44fc8daefacd3b7481a0,
title = "Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET",
abstract = "High-resolution cardiac PET imaging with emphasis on quantification would benefit from eliminating the problem of respiratory movement during data acquisition. Respiratory gating on the basis of list-mode data has been employed previously as one approach to reduce motion effects. However, it results in poor count statistics with degradation of image quality. This work reports on the implementation of a technique to correct for respiratory motion in the area of the heart at no extra cost for count statistics and with the potential to maintain ECG gating, based on rigid-body transformations on list-mode data event-by-event. A motion-corrected data set is obtained by assigning, after pre-correction for detector efficiency and photon attenuation, individual lines-of-response to new detector pairs with consideration of respiratory motion. Parameters of respiratory motion are obtained from a series of gated image sets by means of image registration. Respiration is recorded simultaneously with the list-mode data using an inductive respiration monitor with an elasticized belt at chest level. The accuracy of the technique was assessed with point-source data showing a good correlation between measured and true transformations. The technique was applied on phantom data with simulated respiratory motion, showing successful recovery of tracer distribution and contrast on the motion-corrected images, and on patient data with C 15O and 18FDG. Quantitative assessment of preliminary C15O patient data showed improvement in the recovery coefficient at the centre of the left ventricle.",
author = "L. Livieratos and L. Stegger and Bloomfield, {P. M.} and K. Schafers and Bailey, {D. L.} and Camici, {P. G.}",
year = "2005",
month = "7",
day = "21",
doi = "10.1088/0031-9155/50/14/008",
language = "English",
volume = "50",
pages = "3313--3322",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "14",

}

TY - JOUR

T1 - Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET

AU - Livieratos, L.

AU - Stegger, L.

AU - Bloomfield, P. M.

AU - Schafers, K.

AU - Bailey, D. L.

AU - Camici, P. G.

PY - 2005/7/21

Y1 - 2005/7/21

N2 - High-resolution cardiac PET imaging with emphasis on quantification would benefit from eliminating the problem of respiratory movement during data acquisition. Respiratory gating on the basis of list-mode data has been employed previously as one approach to reduce motion effects. However, it results in poor count statistics with degradation of image quality. This work reports on the implementation of a technique to correct for respiratory motion in the area of the heart at no extra cost for count statistics and with the potential to maintain ECG gating, based on rigid-body transformations on list-mode data event-by-event. A motion-corrected data set is obtained by assigning, after pre-correction for detector efficiency and photon attenuation, individual lines-of-response to new detector pairs with consideration of respiratory motion. Parameters of respiratory motion are obtained from a series of gated image sets by means of image registration. Respiration is recorded simultaneously with the list-mode data using an inductive respiration monitor with an elasticized belt at chest level. The accuracy of the technique was assessed with point-source data showing a good correlation between measured and true transformations. The technique was applied on phantom data with simulated respiratory motion, showing successful recovery of tracer distribution and contrast on the motion-corrected images, and on patient data with C 15O and 18FDG. Quantitative assessment of preliminary C15O patient data showed improvement in the recovery coefficient at the centre of the left ventricle.

AB - High-resolution cardiac PET imaging with emphasis on quantification would benefit from eliminating the problem of respiratory movement during data acquisition. Respiratory gating on the basis of list-mode data has been employed previously as one approach to reduce motion effects. However, it results in poor count statistics with degradation of image quality. This work reports on the implementation of a technique to correct for respiratory motion in the area of the heart at no extra cost for count statistics and with the potential to maintain ECG gating, based on rigid-body transformations on list-mode data event-by-event. A motion-corrected data set is obtained by assigning, after pre-correction for detector efficiency and photon attenuation, individual lines-of-response to new detector pairs with consideration of respiratory motion. Parameters of respiratory motion are obtained from a series of gated image sets by means of image registration. Respiration is recorded simultaneously with the list-mode data using an inductive respiration monitor with an elasticized belt at chest level. The accuracy of the technique was assessed with point-source data showing a good correlation between measured and true transformations. The technique was applied on phantom data with simulated respiratory motion, showing successful recovery of tracer distribution and contrast on the motion-corrected images, and on patient data with C 15O and 18FDG. Quantitative assessment of preliminary C15O patient data showed improvement in the recovery coefficient at the centre of the left ventricle.

UR - http://www.scopus.com/inward/record.url?scp=22244488754&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=22244488754&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/50/14/008

DO - 10.1088/0031-9155/50/14/008

M3 - Article

C2 - 16177511

AN - SCOPUS:22244488754

VL - 50

SP - 3313

EP - 3322

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 14

ER -