Role of tricuspid regurgitation in fetal echocardiographic diagnosis of pulmonary atresia with intact ventricular septum

R. Iacobelli, L. Pasquini, A. Toscano, F. Raimondi, G. Michielon, A. E. Tozzi, S. P. Sanders

Research output: Contribution to journalArticlepeer-review

Abstract

Objective: Pulmonary atresia with intact ventricular septum (PAIVS) is a rare cardiac malformation with a broad spectrum of anatomical manifestations, varying from types suitable for biventricular repair to those with diminutive right ventricle and primitive ventriculocoronary connections (VCC), more suitable for single-ventricle palliation or heart transplantation. We sought to test whether tricuspid regurgitation is an easily detectable prenatal criterion with which to identify PAIVS patients at lower risk of needing postnatal single-ventricle palliation. Method: We identified retrospectively patients with both fetal diagnosis and postnatal confirmation of PAIVS who were seen at Bambino Gesù Hospital between January 2000 and December 2006. Tricuspid valve/mitral valve (TV/MV) ratio, presence and severity of tricuspid regurgitation and direct visualization of VCC were evaluated by echocardiography both pre- and postnatally. Results: We identified 22 patients with a prenatal diagnosis of PAIVS. Four pregnancies were terminated and one fetus was lost to follow-up, leaving 17 patients for the analysis. Based on postnatal cardiac catheterization and/or echocardiography we divided our population in two groups: Group 1 included 10 patients with VCC; Group 2 included seven patients without VCC. At fetal echocardiography, tricuspid regurgitation was absent in all ten Group 1 patients and present in all seven Group 2 patients. VCC were seen directly in 6/10 Group 1 patients and in no Group 2 patients. A cut-off value of 0.56 for the TV/MV ratio was highly predictive of VCC during fetal life, with a sensitivity of 100% and a specificity of 90%. Conclusions: The absence of tricuspid regurgitation in fetuses affected by PAIVS is a strong prenatal echocardiographic predictor of VCC, as is a TV/MV ratio

Original languageEnglish
Pages (from-to)31-35
Number of pages5
JournalUltrasound in Obstetrics and Gynecology
Volume32
Issue number1
DOIs
Publication statusPublished - Jul 2008

Keywords

  • Congenital heart disease
  • Fetal echocardiography
  • Pulmonary atresia with intact ventricular septum (PAIVS)
  • Tricuspid regurgitation
  • Ventriculocoronary connections (VCC)

ASJC Scopus subject areas

  • Obstetrics and Gynaecology
  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology
  • Reproductive Medicine

Fingerprint Dive into the research topics of 'Role of tricuspid regurgitation in fetal echocardiographic diagnosis of pulmonary atresia with intact ventricular septum'. Together they form a unique fingerprint.

Cite this