Rotating-disc micro-solid phase extraction of F2-isoprostanes from maternal and cord plasma by using oxidized buckypaper as sorbent membrane

Pierpaolo Tomai, Andrea Martinelli, Tecla Gasperi, Maria Bianchi, Velia Purcaro, Luciana Teofili, Patrizia Papacci, Maria Sofia Cori, Giovanni Vento, Roberta Curini, Salvatore Fanali, Alessandra Gentili

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This paper describes the development of an original micro-solid phase extraction device and its evaluation for the isolation of F2-isoprostanes (F2-IsoPs) from cord and maternal plasma samples. The unit is very simple and consists in a rotating disc (1.8 cm diameter) of oxidized buckypaper (BP), enwrapped in a polypropylene mesh pouch. Even if the selected F2-IsoPs have logP and pKa values that make them suitable candidates for their sorption on BP, several parameters were optimized to maximize recoveries: time of adsorption and desorption; stirring speed; volume, pH and ionic strength of the sample; type, volume, and fractions of the elution solvent; oxidation grade of BP. Among all, the last one was crucial in affecting extraction yields because of the analyte interactions with polar functionalities, introduced by a preliminary oxidative acid treatment. The investigation established the optimal oxidation time and highlighted the pros and cons of the acid activation step. All extracts were analyzed by means of liquid chromatography-tandem mass spectrometry (LC–MS/MS). Validation was performed according to the main FDA guidelines for bioanalytical methods. Depending on the spike level and analyte, recoveries ranged between 30 and 120% with precision and accuracy values lower than 20%. Quantitative analysis was accomplished by matrix-matched calibration curves whose determination coefficients were higher than 0.95. Lower limit of quantitation (LLOQ) spanned the range 2.45–6.77 μg L−1. The validated method was applied to the analysis of eight pairs of mother/child plasma samples, revealing the presence of 8-iso-15-keto-PGF and 8-iso-PGE2 at a concentration of about 10 μg L−1 in most cord plasma samples of preterm newborns.

Original languageEnglish
JournalJournal of Chromatography A
DOIs
Publication statusAccepted/In press - Jan 1 2018

Fingerprint

F2-Isoprostanes
Solid Phase Extraction
Rotating disks
Sorbents
Mothers
Membranes
Plasmas
Recovery
Oxidation
Acids
Dinoprost
Polypropylenes
Liquid chromatography
Tandem Mass Spectrometry
Ionic strength
Liquid Chromatography
Osmolar Concentration
Calibration
Adsorption
Mass spectrometry

Keywords

  • Biological samples
  • Buckypaper
  • Carbon nanotubes
  • LC–MS
  • Sample preparation
  • Solid phase extraction

ASJC Scopus subject areas

  • Analytical Chemistry
  • Biochemistry
  • Organic Chemistry

Cite this

Rotating-disc micro-solid phase extraction of F2-isoprostanes from maternal and cord plasma by using oxidized buckypaper as sorbent membrane. / Tomai, Pierpaolo; Martinelli, Andrea; Gasperi, Tecla; Bianchi, Maria; Purcaro, Velia; Teofili, Luciana; Papacci, Patrizia; Cori, Maria Sofia; Vento, Giovanni; Curini, Roberta; Fanali, Salvatore; Gentili, Alessandra.

In: Journal of Chromatography A, 01.01.2018.

Research output: Contribution to journalArticle

Tomai, Pierpaolo ; Martinelli, Andrea ; Gasperi, Tecla ; Bianchi, Maria ; Purcaro, Velia ; Teofili, Luciana ; Papacci, Patrizia ; Cori, Maria Sofia ; Vento, Giovanni ; Curini, Roberta ; Fanali, Salvatore ; Gentili, Alessandra. / Rotating-disc micro-solid phase extraction of F2-isoprostanes from maternal and cord plasma by using oxidized buckypaper as sorbent membrane. In: Journal of Chromatography A. 2018.
@article{d68c45be05104cf9a592b5642856d64b,
title = "Rotating-disc micro-solid phase extraction of F2-isoprostanes from maternal and cord plasma by using oxidized buckypaper as sorbent membrane",
abstract = "This paper describes the development of an original micro-solid phase extraction device and its evaluation for the isolation of F2-isoprostanes (F2-IsoPs) from cord and maternal plasma samples. The unit is very simple and consists in a rotating disc (1.8 cm diameter) of oxidized buckypaper (BP), enwrapped in a polypropylene mesh pouch. Even if the selected F2-IsoPs have logP and pKa values that make them suitable candidates for their sorption on BP, several parameters were optimized to maximize recoveries: time of adsorption and desorption; stirring speed; volume, pH and ionic strength of the sample; type, volume, and fractions of the elution solvent; oxidation grade of BP. Among all, the last one was crucial in affecting extraction yields because of the analyte interactions with polar functionalities, introduced by a preliminary oxidative acid treatment. The investigation established the optimal oxidation time and highlighted the pros and cons of the acid activation step. All extracts were analyzed by means of liquid chromatography-tandem mass spectrometry (LC–MS/MS). Validation was performed according to the main FDA guidelines for bioanalytical methods. Depending on the spike level and analyte, recoveries ranged between 30 and 120{\%} with precision and accuracy values lower than 20{\%}. Quantitative analysis was accomplished by matrix-matched calibration curves whose determination coefficients were higher than 0.95. Lower limit of quantitation (LLOQ) spanned the range 2.45–6.77 μg L−1. The validated method was applied to the analysis of eight pairs of mother/child plasma samples, revealing the presence of 8-iso-15-keto-PGF2α and 8-iso-PGE2 at a concentration of about 10 μg L−1 in most cord plasma samples of preterm newborns.",
keywords = "Biological samples, Buckypaper, Carbon nanotubes, LC–MS, Sample preparation, Solid phase extraction",
author = "Pierpaolo Tomai and Andrea Martinelli and Tecla Gasperi and Maria Bianchi and Velia Purcaro and Luciana Teofili and Patrizia Papacci and Cori, {Maria Sofia} and Giovanni Vento and Roberta Curini and Salvatore Fanali and Alessandra Gentili",
year = "2018",
month = "1",
day = "1",
doi = "10.1016/j.chroma.2018.12.011",
language = "English",
journal = "Journal of Chromatography A",
issn = "0021-9673",
publisher = "Elsevier",

}

TY - JOUR

T1 - Rotating-disc micro-solid phase extraction of F2-isoprostanes from maternal and cord plasma by using oxidized buckypaper as sorbent membrane

AU - Tomai, Pierpaolo

AU - Martinelli, Andrea

AU - Gasperi, Tecla

AU - Bianchi, Maria

AU - Purcaro, Velia

AU - Teofili, Luciana

AU - Papacci, Patrizia

AU - Cori, Maria Sofia

AU - Vento, Giovanni

AU - Curini, Roberta

AU - Fanali, Salvatore

AU - Gentili, Alessandra

PY - 2018/1/1

Y1 - 2018/1/1

N2 - This paper describes the development of an original micro-solid phase extraction device and its evaluation for the isolation of F2-isoprostanes (F2-IsoPs) from cord and maternal plasma samples. The unit is very simple and consists in a rotating disc (1.8 cm diameter) of oxidized buckypaper (BP), enwrapped in a polypropylene mesh pouch. Even if the selected F2-IsoPs have logP and pKa values that make them suitable candidates for their sorption on BP, several parameters were optimized to maximize recoveries: time of adsorption and desorption; stirring speed; volume, pH and ionic strength of the sample; type, volume, and fractions of the elution solvent; oxidation grade of BP. Among all, the last one was crucial in affecting extraction yields because of the analyte interactions with polar functionalities, introduced by a preliminary oxidative acid treatment. The investigation established the optimal oxidation time and highlighted the pros and cons of the acid activation step. All extracts were analyzed by means of liquid chromatography-tandem mass spectrometry (LC–MS/MS). Validation was performed according to the main FDA guidelines for bioanalytical methods. Depending on the spike level and analyte, recoveries ranged between 30 and 120% with precision and accuracy values lower than 20%. Quantitative analysis was accomplished by matrix-matched calibration curves whose determination coefficients were higher than 0.95. Lower limit of quantitation (LLOQ) spanned the range 2.45–6.77 μg L−1. The validated method was applied to the analysis of eight pairs of mother/child plasma samples, revealing the presence of 8-iso-15-keto-PGF2α and 8-iso-PGE2 at a concentration of about 10 μg L−1 in most cord plasma samples of preterm newborns.

AB - This paper describes the development of an original micro-solid phase extraction device and its evaluation for the isolation of F2-isoprostanes (F2-IsoPs) from cord and maternal plasma samples. The unit is very simple and consists in a rotating disc (1.8 cm diameter) of oxidized buckypaper (BP), enwrapped in a polypropylene mesh pouch. Even if the selected F2-IsoPs have logP and pKa values that make them suitable candidates for their sorption on BP, several parameters were optimized to maximize recoveries: time of adsorption and desorption; stirring speed; volume, pH and ionic strength of the sample; type, volume, and fractions of the elution solvent; oxidation grade of BP. Among all, the last one was crucial in affecting extraction yields because of the analyte interactions with polar functionalities, introduced by a preliminary oxidative acid treatment. The investigation established the optimal oxidation time and highlighted the pros and cons of the acid activation step. All extracts were analyzed by means of liquid chromatography-tandem mass spectrometry (LC–MS/MS). Validation was performed according to the main FDA guidelines for bioanalytical methods. Depending on the spike level and analyte, recoveries ranged between 30 and 120% with precision and accuracy values lower than 20%. Quantitative analysis was accomplished by matrix-matched calibration curves whose determination coefficients were higher than 0.95. Lower limit of quantitation (LLOQ) spanned the range 2.45–6.77 μg L−1. The validated method was applied to the analysis of eight pairs of mother/child plasma samples, revealing the presence of 8-iso-15-keto-PGF2α and 8-iso-PGE2 at a concentration of about 10 μg L−1 in most cord plasma samples of preterm newborns.

KW - Biological samples

KW - Buckypaper

KW - Carbon nanotubes

KW - LC–MS

KW - Sample preparation

KW - Solid phase extraction

UR - http://www.scopus.com/inward/record.url?scp=85058380116&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85058380116&partnerID=8YFLogxK

U2 - 10.1016/j.chroma.2018.12.011

DO - 10.1016/j.chroma.2018.12.011

M3 - Article

AN - SCOPUS:85058380116

JO - Journal of Chromatography A

JF - Journal of Chromatography A

SN - 0021-9673

ER -