Abstract
PURPOSE: To analyze the surface roughness of porcine corneas after excimer laser ablation with and without the smoothing procedure by means of atomic force microscopy. METHODS: Excimer laser photorefractive keratectomy (PRK) was performed on eight porcine corneas. Immediately following the procedure, smoothing was performed on four corneas using a viscous solution of 0.25% sodium hyaluronate. The corneas were examined in balanced salt solution after fixation in 2.5% glutaraldehyde solution using atomic force microscopy. Quantitative analysis of the ablated stromal surface topography was performed using the section analysis module of the atomic force microscopy software. Repeated measurements were made over small areas (≤50 μm2) near the center of each ablation, with a vertical resolution of
Original language | English |
---|---|
Pages (from-to) | 469-475 |
Number of pages | 7 |
Journal | Journal of Refractive Surgery |
Volume | 21 |
Issue number | 5 |
Publication status | Published - Sep 2005 |