Signal-to-noise ratio of diffusion weighted magnetic resonance imaging: Estimation methods and in vivo application to spinal cord

Ludovica Griffanti, Francesca Baglio, Maria Giulia Preti, Pietro Cecconi, Marco Rovaris, Giuseppe Baselli, Maria Marcella Laganà

Research output: Contribution to journalArticle

Abstract

Diffusion tensor imaging (DTI) and tractographic reconstruction may be applied for in vivo clinical spinal cord studies. However, this structure represents a challenge to current acquisition and reconstruction strategies, due to its small size, motion artifacts, partial volume effects and low signal-to-noise-ratio (SNR). Aims of this work were to select the best approach for the estimate of SNR and to use it for spinal cord diffusion weighted (DW) sequence optimization. Seven methods for the estimate of SNR were compared on uniform phantom DW images, and the best performing approach (single ROI for signal and noise, difference of images - SNR diff) was applied for the following in vivo sequence evaluations. Fifteen sequences with different parameters (voxel size, repetition (TR) and echo (TE) times) were compared according to SNR, resolution, fractional anisotropy (FA) and tractography performances on three healthy volunteers. In vivo optimization of DW sequences resulted in: axial sequence, with voxel size = 1.5 mm × 1.5 mm × 3.5 mm, TR = 3200 ms and TE = 89 ms, sagittal sequence with voxel size = 2.2 mm × 2.2 mm × 2 mm, TR = 3000 ms and TE = 84 ms. An objective method tested on phantom and a practical index for in vivo spinal cord DTI SNR estimation allowed to obtain axial and sagittal optimized sequences, providing excellent tractographic results, with acceptable acquisition times for in vivo clinical applications.

Original languageEnglish
Pages (from-to)285-294
Number of pages10
JournalBiomedical Signal Processing and Control
Volume7
Issue number3
DOIs
Publication statusPublished - May 2012

Fingerprint

Diffusion Magnetic Resonance Imaging
Signal-To-Noise Ratio
Magnetic resonance
Spinal Cord
Signal to noise ratio
Imaging techniques
Diffusion tensor imaging
Diffusion Tensor Imaging
Anisotropy
Artifacts
Healthy Volunteers

Keywords

  • Diffusion tensor imaging
  • Sequence optimization
  • Signal-to-noise-ratio
  • Spinal cord

ASJC Scopus subject areas

  • Health Informatics
  • Signal Processing

Cite this

Signal-to-noise ratio of diffusion weighted magnetic resonance imaging : Estimation methods and in vivo application to spinal cord. / Griffanti, Ludovica; Baglio, Francesca; Preti, Maria Giulia; Cecconi, Pietro; Rovaris, Marco; Baselli, Giuseppe; Laganà, Maria Marcella.

In: Biomedical Signal Processing and Control, Vol. 7, No. 3, 05.2012, p. 285-294.

Research output: Contribution to journalArticle

@article{d8d282d3c2144beea0238064bfd4184c,
title = "Signal-to-noise ratio of diffusion weighted magnetic resonance imaging: Estimation methods and in vivo application to spinal cord",
abstract = "Diffusion tensor imaging (DTI) and tractographic reconstruction may be applied for in vivo clinical spinal cord studies. However, this structure represents a challenge to current acquisition and reconstruction strategies, due to its small size, motion artifacts, partial volume effects and low signal-to-noise-ratio (SNR). Aims of this work were to select the best approach for the estimate of SNR and to use it for spinal cord diffusion weighted (DW) sequence optimization. Seven methods for the estimate of SNR were compared on uniform phantom DW images, and the best performing approach (single ROI for signal and noise, difference of images - SNR diff) was applied for the following in vivo sequence evaluations. Fifteen sequences with different parameters (voxel size, repetition (TR) and echo (TE) times) were compared according to SNR, resolution, fractional anisotropy (FA) and tractography performances on three healthy volunteers. In vivo optimization of DW sequences resulted in: axial sequence, with voxel size = 1.5 mm × 1.5 mm × 3.5 mm, TR = 3200 ms and TE = 89 ms, sagittal sequence with voxel size = 2.2 mm × 2.2 mm × 2 mm, TR = 3000 ms and TE = 84 ms. An objective method tested on phantom and a practical index for in vivo spinal cord DTI SNR estimation allowed to obtain axial and sagittal optimized sequences, providing excellent tractographic results, with acceptable acquisition times for in vivo clinical applications.",
keywords = "Diffusion tensor imaging, Sequence optimization, Signal-to-noise-ratio, Spinal cord",
author = "Ludovica Griffanti and Francesca Baglio and Preti, {Maria Giulia} and Pietro Cecconi and Marco Rovaris and Giuseppe Baselli and Lagan{\`a}, {Maria Marcella}",
year = "2012",
month = "5",
doi = "10.1016/j.bspc.2011.06.003",
language = "English",
volume = "7",
pages = "285--294",
journal = "Biomedical Signal Processing and Control",
issn = "1746-8094",
publisher = "Elsevier BV",
number = "3",

}

TY - JOUR

T1 - Signal-to-noise ratio of diffusion weighted magnetic resonance imaging

T2 - Estimation methods and in vivo application to spinal cord

AU - Griffanti, Ludovica

AU - Baglio, Francesca

AU - Preti, Maria Giulia

AU - Cecconi, Pietro

AU - Rovaris, Marco

AU - Baselli, Giuseppe

AU - Laganà, Maria Marcella

PY - 2012/5

Y1 - 2012/5

N2 - Diffusion tensor imaging (DTI) and tractographic reconstruction may be applied for in vivo clinical spinal cord studies. However, this structure represents a challenge to current acquisition and reconstruction strategies, due to its small size, motion artifacts, partial volume effects and low signal-to-noise-ratio (SNR). Aims of this work were to select the best approach for the estimate of SNR and to use it for spinal cord diffusion weighted (DW) sequence optimization. Seven methods for the estimate of SNR were compared on uniform phantom DW images, and the best performing approach (single ROI for signal and noise, difference of images - SNR diff) was applied for the following in vivo sequence evaluations. Fifteen sequences with different parameters (voxel size, repetition (TR) and echo (TE) times) were compared according to SNR, resolution, fractional anisotropy (FA) and tractography performances on three healthy volunteers. In vivo optimization of DW sequences resulted in: axial sequence, with voxel size = 1.5 mm × 1.5 mm × 3.5 mm, TR = 3200 ms and TE = 89 ms, sagittal sequence with voxel size = 2.2 mm × 2.2 mm × 2 mm, TR = 3000 ms and TE = 84 ms. An objective method tested on phantom and a practical index for in vivo spinal cord DTI SNR estimation allowed to obtain axial and sagittal optimized sequences, providing excellent tractographic results, with acceptable acquisition times for in vivo clinical applications.

AB - Diffusion tensor imaging (DTI) and tractographic reconstruction may be applied for in vivo clinical spinal cord studies. However, this structure represents a challenge to current acquisition and reconstruction strategies, due to its small size, motion artifacts, partial volume effects and low signal-to-noise-ratio (SNR). Aims of this work were to select the best approach for the estimate of SNR and to use it for spinal cord diffusion weighted (DW) sequence optimization. Seven methods for the estimate of SNR were compared on uniform phantom DW images, and the best performing approach (single ROI for signal and noise, difference of images - SNR diff) was applied for the following in vivo sequence evaluations. Fifteen sequences with different parameters (voxel size, repetition (TR) and echo (TE) times) were compared according to SNR, resolution, fractional anisotropy (FA) and tractography performances on three healthy volunteers. In vivo optimization of DW sequences resulted in: axial sequence, with voxel size = 1.5 mm × 1.5 mm × 3.5 mm, TR = 3200 ms and TE = 89 ms, sagittal sequence with voxel size = 2.2 mm × 2.2 mm × 2 mm, TR = 3000 ms and TE = 84 ms. An objective method tested on phantom and a practical index for in vivo spinal cord DTI SNR estimation allowed to obtain axial and sagittal optimized sequences, providing excellent tractographic results, with acceptable acquisition times for in vivo clinical applications.

KW - Diffusion tensor imaging

KW - Sequence optimization

KW - Signal-to-noise-ratio

KW - Spinal cord

UR - http://www.scopus.com/inward/record.url?scp=84860251302&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84860251302&partnerID=8YFLogxK

U2 - 10.1016/j.bspc.2011.06.003

DO - 10.1016/j.bspc.2011.06.003

M3 - Article

AN - SCOPUS:84860251302

VL - 7

SP - 285

EP - 294

JO - Biomedical Signal Processing and Control

JF - Biomedical Signal Processing and Control

SN - 1746-8094

IS - 3

ER -