Simple estimate of the true right to left shunt (Qs/Qt) at maintenance F1O2 by Sulphur Hexafluoride retention

A. Pesenti, R. Latini, A. Riboni, L. Gattinoni

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

Differentiating Qs/Qt over Qva/Q (as measured by the standard O2 content formula) appears to be of great interest in applying and evaluating different therapeutic approaches. The estimation of Qs/Qt by 100% O2 breathing may alter "per se" the lung condition and is unsatisfactory. We used Sulphur Hexafluoride (SF6; λ=6.10-3 ml ml-1 760 mmHg-1) to identify the true shunt (VA/Q1O2. A simple and rapid determination of SF6 retention is performed by ECD gas chromatography from contemporaneous arterial and mixed venous blood samples, taken during i.v. infusion of an SF6 containing solution. Qs/Qt estimate is then given by the ratio: PaSF6/P {Mathematical expression}SF6. It is not necessary to know the absolute gas partial pressures or concentration, hence absolute gas calibrations are not required. This method is suggested as feasible and satisfactory for clinical use, allowing the determination of Qs/Qt at the maintenance F1O2.

Original languageEnglish
Pages (from-to)283-286
Number of pages4
JournalIntensive Care Medicine
Volume8
Issue number6
DOIs
Publication statusPublished - 1982

Fingerprint

Sulfur Hexafluoride
Gases
Maintenance
Partial Pressure
Gas Chromatography
Calibration
Respiration
Lung
Therapeutics

Keywords

  • Inert gas retention
  • Lung arteriovenous shunt
  • Lung ventilation perfusion ratio
  • Sulphur hexafluoride

ASJC Scopus subject areas

  • Critical Care and Intensive Care Medicine

Cite this

Simple estimate of the true right to left shunt (Qs/Qt) at maintenance F1O2 by Sulphur Hexafluoride retention. / Pesenti, A.; Latini, R.; Riboni, A.; Gattinoni, L.

In: Intensive Care Medicine, Vol. 8, No. 6, 1982, p. 283-286.

Research output: Contribution to journalArticle

@article{73b40c628b764d8192a0357e792e5ca9,
title = "Simple estimate of the true right to left shunt (Qs/Qt) at maintenance F1O2 by Sulphur Hexafluoride retention",
abstract = "Differentiating Qs/Qt over Qva/Q (as measured by the standard O2 content formula) appears to be of great interest in applying and evaluating different therapeutic approaches. The estimation of Qs/Qt by 100{\%} O2 breathing may alter {"}per se{"} the lung condition and is unsatisfactory. We used Sulphur Hexafluoride (SF6; λ=6.10-3 ml ml-1 760 mmHg-1) to identify the true shunt (VA/Q1O2. A simple and rapid determination of SF6 retention is performed by ECD gas chromatography from contemporaneous arterial and mixed venous blood samples, taken during i.v. infusion of an SF6 containing solution. Qs/Qt estimate is then given by the ratio: PaSF6/P {Mathematical expression}SF6. It is not necessary to know the absolute gas partial pressures or concentration, hence absolute gas calibrations are not required. This method is suggested as feasible and satisfactory for clinical use, allowing the determination of Qs/Qt at the maintenance F1O2.",
keywords = "Inert gas retention, Lung arteriovenous shunt, Lung ventilation perfusion ratio, Sulphur hexafluoride",
author = "A. Pesenti and R. Latini and A. Riboni and L. Gattinoni",
year = "1982",
doi = "10.1007/BF01716739",
language = "English",
volume = "8",
pages = "283--286",
journal = "Intensive Care Medicine",
issn = "0342-4642",
publisher = "Springer Verlag",
number = "6",

}

TY - JOUR

T1 - Simple estimate of the true right to left shunt (Qs/Qt) at maintenance F1O2 by Sulphur Hexafluoride retention

AU - Pesenti, A.

AU - Latini, R.

AU - Riboni, A.

AU - Gattinoni, L.

PY - 1982

Y1 - 1982

N2 - Differentiating Qs/Qt over Qva/Q (as measured by the standard O2 content formula) appears to be of great interest in applying and evaluating different therapeutic approaches. The estimation of Qs/Qt by 100% O2 breathing may alter "per se" the lung condition and is unsatisfactory. We used Sulphur Hexafluoride (SF6; λ=6.10-3 ml ml-1 760 mmHg-1) to identify the true shunt (VA/Q1O2. A simple and rapid determination of SF6 retention is performed by ECD gas chromatography from contemporaneous arterial and mixed venous blood samples, taken during i.v. infusion of an SF6 containing solution. Qs/Qt estimate is then given by the ratio: PaSF6/P {Mathematical expression}SF6. It is not necessary to know the absolute gas partial pressures or concentration, hence absolute gas calibrations are not required. This method is suggested as feasible and satisfactory for clinical use, allowing the determination of Qs/Qt at the maintenance F1O2.

AB - Differentiating Qs/Qt over Qva/Q (as measured by the standard O2 content formula) appears to be of great interest in applying and evaluating different therapeutic approaches. The estimation of Qs/Qt by 100% O2 breathing may alter "per se" the lung condition and is unsatisfactory. We used Sulphur Hexafluoride (SF6; λ=6.10-3 ml ml-1 760 mmHg-1) to identify the true shunt (VA/Q1O2. A simple and rapid determination of SF6 retention is performed by ECD gas chromatography from contemporaneous arterial and mixed venous blood samples, taken during i.v. infusion of an SF6 containing solution. Qs/Qt estimate is then given by the ratio: PaSF6/P {Mathematical expression}SF6. It is not necessary to know the absolute gas partial pressures or concentration, hence absolute gas calibrations are not required. This method is suggested as feasible and satisfactory for clinical use, allowing the determination of Qs/Qt at the maintenance F1O2.

KW - Inert gas retention

KW - Lung arteriovenous shunt

KW - Lung ventilation perfusion ratio

KW - Sulphur hexafluoride

UR - http://www.scopus.com/inward/record.url?scp=0019973163&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019973163&partnerID=8YFLogxK

U2 - 10.1007/BF01716739

DO - 10.1007/BF01716739

M3 - Article

C2 - 7175012

AN - SCOPUS:0019973163

VL - 8

SP - 283

EP - 286

JO - Intensive Care Medicine

JF - Intensive Care Medicine

SN - 0342-4642

IS - 6

ER -