Simultaneous Amplitude Frequency Electrogram Transformation (SAFE-T) Mapping to Identify Ventricular Tachycardia Arrhythmogenic Potentials in Sinus Rhythm

Chin Yu Lin, John Silberbauer, Yenn Jiang Lin, Men Tzung Lo, Chen Lin, Hsiang Chih Chang, Shih Lin Chang, Li Wei Lo, Yu Feng Hu, Fa Po Chung, Jo Nan Liao, Yun Yu Chen, Chun Wang Chiou, Shih Ann Chen, Paolo Della Bella

Research output: Contribution to journalArticle

Abstract

Objectives This study sought to develop a novel automated technique, simultaneous amplitude frequency electrogram transformation (SAFE-T), to identify ventricular tachycardia (VT) isthmuses by analysis of sinus rhythm arrhythmogenic potentials (AP). Background Substrate ablation is useful for patients with scar-related hemodynamically unstable VT; however, the accuracy of different approaches remains inadequate, varying from targeting late potentials to full scar homogenization. Methods High-density ventricular mapping was performed in 3 groups: 1) 18 normal heart control subjects; 2) 10 ischemic patients; and 3) 8 nonischemic VT patients. In VT patients, isthmus sites were characterized using entrainment responses. Sinus rhythm right ventricle/left ventricle endocardial and epicardial electrograms underwent Hilbert-Huang spectral analysis and were displayed as 3-dimensional SAFE-T maps. AP and their relation to the VT isthmus sites were studied. Results AP were defined by a cutoff value of 3.08 Hz mV using normal heart control subjects. Receiver-operating characteristics showed that VT isthmus sites were best identified using SAFE-T mapping (p < 0.001) as compared with bipolar and unipolar scar and late potential mapping with an optimal cutoff value of 3.09 Hz mV, allowing identification of 100% of the 34 mapped VT isthmuses, compared with 68% using late potentials. There was no significant difference between sinus rhythm and paced SAFE-T values. Abnormal SAFE-T areas involved about one-quarter of the scar total area. Conclusions Automated electrogram analysis using 3-dimensional SAFE-T mapping allows rapid and objective identification of AP that reliably detect VT isthmuses. The results suggest that SAFE-T mapping is good alternative strategy to late potential mapping in identifying VT isthmuses and allows reduced ablation as compared to scar homogenization.

Original languageEnglish
Pages (from-to)459-470
Number of pages12
JournalJACC: Clinical Electrophysiology
Volume2
Issue number4
DOIs
Publication statusPublished - Aug 1 2016

Fingerprint

Ventricular Tachycardia
Cicatrix
Heart Ventricles
ROC Curve

Keywords

  • arrhythmogenic potentials
  • catheter ablation
  • Hilbert-Huang transform
  • isthmus
  • ventricular tachycardia

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Cite this

Simultaneous Amplitude Frequency Electrogram Transformation (SAFE-T) Mapping to Identify Ventricular Tachycardia Arrhythmogenic Potentials in Sinus Rhythm. / Lin, Chin Yu; Silberbauer, John; Lin, Yenn Jiang; Lo, Men Tzung; Lin, Chen; Chang, Hsiang Chih; Chang, Shih Lin; Lo, Li Wei; Hu, Yu Feng; Chung, Fa Po; Liao, Jo Nan; Chen, Yun Yu; Chiou, Chun Wang; Chen, Shih Ann; Della Bella, Paolo.

In: JACC: Clinical Electrophysiology, Vol. 2, No. 4, 01.08.2016, p. 459-470.

Research output: Contribution to journalArticle

Lin, CY, Silberbauer, J, Lin, YJ, Lo, MT, Lin, C, Chang, HC, Chang, SL, Lo, LW, Hu, YF, Chung, FP, Liao, JN, Chen, YY, Chiou, CW, Chen, SA & Della Bella, P 2016, 'Simultaneous Amplitude Frequency Electrogram Transformation (SAFE-T) Mapping to Identify Ventricular Tachycardia Arrhythmogenic Potentials in Sinus Rhythm', JACC: Clinical Electrophysiology, vol. 2, no. 4, pp. 459-470. https://doi.org/10.1016/j.jacep.2016.01.013
Lin, Chin Yu ; Silberbauer, John ; Lin, Yenn Jiang ; Lo, Men Tzung ; Lin, Chen ; Chang, Hsiang Chih ; Chang, Shih Lin ; Lo, Li Wei ; Hu, Yu Feng ; Chung, Fa Po ; Liao, Jo Nan ; Chen, Yun Yu ; Chiou, Chun Wang ; Chen, Shih Ann ; Della Bella, Paolo. / Simultaneous Amplitude Frequency Electrogram Transformation (SAFE-T) Mapping to Identify Ventricular Tachycardia Arrhythmogenic Potentials in Sinus Rhythm. In: JACC: Clinical Electrophysiology. 2016 ; Vol. 2, No. 4. pp. 459-470.
@article{0791561cc0644835898ef10707150d62,
title = "Simultaneous Amplitude Frequency Electrogram Transformation (SAFE-T) Mapping to Identify Ventricular Tachycardia Arrhythmogenic Potentials in Sinus Rhythm",
abstract = "Objectives This study sought to develop a novel automated technique, simultaneous amplitude frequency electrogram transformation (SAFE-T), to identify ventricular tachycardia (VT) isthmuses by analysis of sinus rhythm arrhythmogenic potentials (AP). Background Substrate ablation is useful for patients with scar-related hemodynamically unstable VT; however, the accuracy of different approaches remains inadequate, varying from targeting late potentials to full scar homogenization. Methods High-density ventricular mapping was performed in 3 groups: 1) 18 normal heart control subjects; 2) 10 ischemic patients; and 3) 8 nonischemic VT patients. In VT patients, isthmus sites were characterized using entrainment responses. Sinus rhythm right ventricle/left ventricle endocardial and epicardial electrograms underwent Hilbert-Huang spectral analysis and were displayed as 3-dimensional SAFE-T maps. AP and their relation to the VT isthmus sites were studied. Results AP were defined by a cutoff value of 3.08 Hz mV using normal heart control subjects. Receiver-operating characteristics showed that VT isthmus sites were best identified using SAFE-T mapping (p < 0.001) as compared with bipolar and unipolar scar and late potential mapping with an optimal cutoff value of 3.09 Hz mV, allowing identification of 100{\%} of the 34 mapped VT isthmuses, compared with 68{\%} using late potentials. There was no significant difference between sinus rhythm and paced SAFE-T values. Abnormal SAFE-T areas involved about one-quarter of the scar total area. Conclusions Automated electrogram analysis using 3-dimensional SAFE-T mapping allows rapid and objective identification of AP that reliably detect VT isthmuses. The results suggest that SAFE-T mapping is good alternative strategy to late potential mapping in identifying VT isthmuses and allows reduced ablation as compared to scar homogenization.",
keywords = "arrhythmogenic potentials, catheter ablation, Hilbert-Huang transform, isthmus, ventricular tachycardia",
author = "Lin, {Chin Yu} and John Silberbauer and Lin, {Yenn Jiang} and Lo, {Men Tzung} and Chen Lin and Chang, {Hsiang Chih} and Chang, {Shih Lin} and Lo, {Li Wei} and Hu, {Yu Feng} and Chung, {Fa Po} and Liao, {Jo Nan} and Chen, {Yun Yu} and Chiou, {Chun Wang} and Chen, {Shih Ann} and {Della Bella}, Paolo",
year = "2016",
month = "8",
day = "1",
doi = "10.1016/j.jacep.2016.01.013",
language = "English",
volume = "2",
pages = "459--470",
journal = "JACC: Clinical Electrophysiology",
issn = "2405-5018",
publisher = "Elsevier USA",
number = "4",

}

TY - JOUR

T1 - Simultaneous Amplitude Frequency Electrogram Transformation (SAFE-T) Mapping to Identify Ventricular Tachycardia Arrhythmogenic Potentials in Sinus Rhythm

AU - Lin, Chin Yu

AU - Silberbauer, John

AU - Lin, Yenn Jiang

AU - Lo, Men Tzung

AU - Lin, Chen

AU - Chang, Hsiang Chih

AU - Chang, Shih Lin

AU - Lo, Li Wei

AU - Hu, Yu Feng

AU - Chung, Fa Po

AU - Liao, Jo Nan

AU - Chen, Yun Yu

AU - Chiou, Chun Wang

AU - Chen, Shih Ann

AU - Della Bella, Paolo

PY - 2016/8/1

Y1 - 2016/8/1

N2 - Objectives This study sought to develop a novel automated technique, simultaneous amplitude frequency electrogram transformation (SAFE-T), to identify ventricular tachycardia (VT) isthmuses by analysis of sinus rhythm arrhythmogenic potentials (AP). Background Substrate ablation is useful for patients with scar-related hemodynamically unstable VT; however, the accuracy of different approaches remains inadequate, varying from targeting late potentials to full scar homogenization. Methods High-density ventricular mapping was performed in 3 groups: 1) 18 normal heart control subjects; 2) 10 ischemic patients; and 3) 8 nonischemic VT patients. In VT patients, isthmus sites were characterized using entrainment responses. Sinus rhythm right ventricle/left ventricle endocardial and epicardial electrograms underwent Hilbert-Huang spectral analysis and were displayed as 3-dimensional SAFE-T maps. AP and their relation to the VT isthmus sites were studied. Results AP were defined by a cutoff value of 3.08 Hz mV using normal heart control subjects. Receiver-operating characteristics showed that VT isthmus sites were best identified using SAFE-T mapping (p < 0.001) as compared with bipolar and unipolar scar and late potential mapping with an optimal cutoff value of 3.09 Hz mV, allowing identification of 100% of the 34 mapped VT isthmuses, compared with 68% using late potentials. There was no significant difference between sinus rhythm and paced SAFE-T values. Abnormal SAFE-T areas involved about one-quarter of the scar total area. Conclusions Automated electrogram analysis using 3-dimensional SAFE-T mapping allows rapid and objective identification of AP that reliably detect VT isthmuses. The results suggest that SAFE-T mapping is good alternative strategy to late potential mapping in identifying VT isthmuses and allows reduced ablation as compared to scar homogenization.

AB - Objectives This study sought to develop a novel automated technique, simultaneous amplitude frequency electrogram transformation (SAFE-T), to identify ventricular tachycardia (VT) isthmuses by analysis of sinus rhythm arrhythmogenic potentials (AP). Background Substrate ablation is useful for patients with scar-related hemodynamically unstable VT; however, the accuracy of different approaches remains inadequate, varying from targeting late potentials to full scar homogenization. Methods High-density ventricular mapping was performed in 3 groups: 1) 18 normal heart control subjects; 2) 10 ischemic patients; and 3) 8 nonischemic VT patients. In VT patients, isthmus sites were characterized using entrainment responses. Sinus rhythm right ventricle/left ventricle endocardial and epicardial electrograms underwent Hilbert-Huang spectral analysis and were displayed as 3-dimensional SAFE-T maps. AP and their relation to the VT isthmus sites were studied. Results AP were defined by a cutoff value of 3.08 Hz mV using normal heart control subjects. Receiver-operating characteristics showed that VT isthmus sites were best identified using SAFE-T mapping (p < 0.001) as compared with bipolar and unipolar scar and late potential mapping with an optimal cutoff value of 3.09 Hz mV, allowing identification of 100% of the 34 mapped VT isthmuses, compared with 68% using late potentials. There was no significant difference between sinus rhythm and paced SAFE-T values. Abnormal SAFE-T areas involved about one-quarter of the scar total area. Conclusions Automated electrogram analysis using 3-dimensional SAFE-T mapping allows rapid and objective identification of AP that reliably detect VT isthmuses. The results suggest that SAFE-T mapping is good alternative strategy to late potential mapping in identifying VT isthmuses and allows reduced ablation as compared to scar homogenization.

KW - arrhythmogenic potentials

KW - catheter ablation

KW - Hilbert-Huang transform

KW - isthmus

KW - ventricular tachycardia

UR - http://www.scopus.com/inward/record.url?scp=84990869126&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84990869126&partnerID=8YFLogxK

U2 - 10.1016/j.jacep.2016.01.013

DO - 10.1016/j.jacep.2016.01.013

M3 - Article

AN - SCOPUS:84990869126

VL - 2

SP - 459

EP - 470

JO - JACC: Clinical Electrophysiology

JF - JACC: Clinical Electrophysiology

SN - 2405-5018

IS - 4

ER -