Sister chromatid exchanges and ion release in patients wearing fracture fixation devices

Lucia Savarino, Susanna Stea, Donatella Granchi, Manuela Visentin, Gabriela Ciapetti, M. Elena Donati, Giuseppe Rollo, Gianfranco Zinghi, Arturo Pizzoferrato, Lucio Montanaro, Aldo Toni

Research output: Contribution to journalArticle

29 Citations (Scopus)

Abstract

The quantification of sister chromatid exchange (SCE) during mitosis is a useful index for evaluating genotoxic effects in subjects occupationally or incidentally exposed to potentially toxic substances. The authors investigated the hypothesis that ions released by corrosion from prosthetic components of fracture fixation devices are associated with change in SCE incidence. In the present study, ten patients with implants were examined, and fifteen subjects with no implants were used as controls. SCE and high frequency cell (HFC) numbers were evaluated in circulating lymphocytes. In addition, nickel (Ni) and chromium (Cr) ion values in the serum were measured because, after iron, these metals are major components of stainless steel. A significant increase in SCE numbers was observed in patients compared to the control population (4.9 ± 1.3 vs. 3.5 ± 1.4). Ni concentration was 1.71 ± 1.49 ng/mL in patients and 0.72 ± 0.52 ng/mL in control subjects; Cr concentration was, respectively, 1.01 ± 0.77 ng/mL and 0.19 ± 0.27 ng/mL. The increase of serum Cr and Ni was statistically significant. No correlation was found between the increased Cr concentrations and SCE number while Cr ion levels were found to be significantly correlated to HFC. An inverse correlation between Ni level and SCE numbers was observed. Our findings suggest that Cr release by stainless steel implants could have a genotoxic effect; thus it would be useful to carefully monitor implanted subjects with regard to serum ion dosage, SCE analysts, and HFC evaluation. In any case, it would be appropriate to remove the implant when fracture fixation is reached.

Original languageEnglish
Pages (from-to)21-26
Number of pages6
JournalJournal of Biomedical Materials Research
Volume50
Issue number1
DOIs
Publication statusPublished - 2000

Fingerprint

Fracture fixation
Fracture Fixation
Sister Chromatid Exchange
Chromium
Ion exchange
Ions
Nickel
Equipment and Supplies
Stainless Steel
Stainless steel
Serum
Lymphocytes
Poisons
Prosthetics
Corrosion
Mitosis
Iron
Metals
Cell Count
Incidence

Keywords

  • Fracture fixation device
  • Genotoxicity
  • Metal ions
  • Sister chromatid exchange
  • Stainless steel

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biomaterials

Cite this

Sister chromatid exchanges and ion release in patients wearing fracture fixation devices. / Savarino, Lucia; Stea, Susanna; Granchi, Donatella; Visentin, Manuela; Ciapetti, Gabriela; Donati, M. Elena; Rollo, Giuseppe; Zinghi, Gianfranco; Pizzoferrato, Arturo; Montanaro, Lucio; Toni, Aldo.

In: Journal of Biomedical Materials Research, Vol. 50, No. 1, 2000, p. 21-26.

Research output: Contribution to journalArticle

Savarino, Lucia ; Stea, Susanna ; Granchi, Donatella ; Visentin, Manuela ; Ciapetti, Gabriela ; Donati, M. Elena ; Rollo, Giuseppe ; Zinghi, Gianfranco ; Pizzoferrato, Arturo ; Montanaro, Lucio ; Toni, Aldo. / Sister chromatid exchanges and ion release in patients wearing fracture fixation devices. In: Journal of Biomedical Materials Research. 2000 ; Vol. 50, No. 1. pp. 21-26.
@article{a70109fe1e7c43b39bf78d1a61008dd9,
title = "Sister chromatid exchanges and ion release in patients wearing fracture fixation devices",
abstract = "The quantification of sister chromatid exchange (SCE) during mitosis is a useful index for evaluating genotoxic effects in subjects occupationally or incidentally exposed to potentially toxic substances. The authors investigated the hypothesis that ions released by corrosion from prosthetic components of fracture fixation devices are associated with change in SCE incidence. In the present study, ten patients with implants were examined, and fifteen subjects with no implants were used as controls. SCE and high frequency cell (HFC) numbers were evaluated in circulating lymphocytes. In addition, nickel (Ni) and chromium (Cr) ion values in the serum were measured because, after iron, these metals are major components of stainless steel. A significant increase in SCE numbers was observed in patients compared to the control population (4.9 ± 1.3 vs. 3.5 ± 1.4). Ni concentration was 1.71 ± 1.49 ng/mL in patients and 0.72 ± 0.52 ng/mL in control subjects; Cr concentration was, respectively, 1.01 ± 0.77 ng/mL and 0.19 ± 0.27 ng/mL. The increase of serum Cr and Ni was statistically significant. No correlation was found between the increased Cr concentrations and SCE number while Cr ion levels were found to be significantly correlated to HFC. An inverse correlation between Ni level and SCE numbers was observed. Our findings suggest that Cr release by stainless steel implants could have a genotoxic effect; thus it would be useful to carefully monitor implanted subjects with regard to serum ion dosage, SCE analysts, and HFC evaluation. In any case, it would be appropriate to remove the implant when fracture fixation is reached.",
keywords = "Fracture fixation device, Genotoxicity, Metal ions, Sister chromatid exchange, Stainless steel",
author = "Lucia Savarino and Susanna Stea and Donatella Granchi and Manuela Visentin and Gabriela Ciapetti and Donati, {M. Elena} and Giuseppe Rollo and Gianfranco Zinghi and Arturo Pizzoferrato and Lucio Montanaro and Aldo Toni",
year = "2000",
doi = "10.1002/(SICI)1097-4636(200004)50:1<21::AID-JBM4>3.0.CO;2-R",
language = "English",
volume = "50",
pages = "21--26",
journal = "Journal of Biomedical Materials Research - Part A",
issn = "1549-3296",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Sister chromatid exchanges and ion release in patients wearing fracture fixation devices

AU - Savarino, Lucia

AU - Stea, Susanna

AU - Granchi, Donatella

AU - Visentin, Manuela

AU - Ciapetti, Gabriela

AU - Donati, M. Elena

AU - Rollo, Giuseppe

AU - Zinghi, Gianfranco

AU - Pizzoferrato, Arturo

AU - Montanaro, Lucio

AU - Toni, Aldo

PY - 2000

Y1 - 2000

N2 - The quantification of sister chromatid exchange (SCE) during mitosis is a useful index for evaluating genotoxic effects in subjects occupationally or incidentally exposed to potentially toxic substances. The authors investigated the hypothesis that ions released by corrosion from prosthetic components of fracture fixation devices are associated with change in SCE incidence. In the present study, ten patients with implants were examined, and fifteen subjects with no implants were used as controls. SCE and high frequency cell (HFC) numbers were evaluated in circulating lymphocytes. In addition, nickel (Ni) and chromium (Cr) ion values in the serum were measured because, after iron, these metals are major components of stainless steel. A significant increase in SCE numbers was observed in patients compared to the control population (4.9 ± 1.3 vs. 3.5 ± 1.4). Ni concentration was 1.71 ± 1.49 ng/mL in patients and 0.72 ± 0.52 ng/mL in control subjects; Cr concentration was, respectively, 1.01 ± 0.77 ng/mL and 0.19 ± 0.27 ng/mL. The increase of serum Cr and Ni was statistically significant. No correlation was found between the increased Cr concentrations and SCE number while Cr ion levels were found to be significantly correlated to HFC. An inverse correlation between Ni level and SCE numbers was observed. Our findings suggest that Cr release by stainless steel implants could have a genotoxic effect; thus it would be useful to carefully monitor implanted subjects with regard to serum ion dosage, SCE analysts, and HFC evaluation. In any case, it would be appropriate to remove the implant when fracture fixation is reached.

AB - The quantification of sister chromatid exchange (SCE) during mitosis is a useful index for evaluating genotoxic effects in subjects occupationally or incidentally exposed to potentially toxic substances. The authors investigated the hypothesis that ions released by corrosion from prosthetic components of fracture fixation devices are associated with change in SCE incidence. In the present study, ten patients with implants were examined, and fifteen subjects with no implants were used as controls. SCE and high frequency cell (HFC) numbers were evaluated in circulating lymphocytes. In addition, nickel (Ni) and chromium (Cr) ion values in the serum were measured because, after iron, these metals are major components of stainless steel. A significant increase in SCE numbers was observed in patients compared to the control population (4.9 ± 1.3 vs. 3.5 ± 1.4). Ni concentration was 1.71 ± 1.49 ng/mL in patients and 0.72 ± 0.52 ng/mL in control subjects; Cr concentration was, respectively, 1.01 ± 0.77 ng/mL and 0.19 ± 0.27 ng/mL. The increase of serum Cr and Ni was statistically significant. No correlation was found between the increased Cr concentrations and SCE number while Cr ion levels were found to be significantly correlated to HFC. An inverse correlation between Ni level and SCE numbers was observed. Our findings suggest that Cr release by stainless steel implants could have a genotoxic effect; thus it would be useful to carefully monitor implanted subjects with regard to serum ion dosage, SCE analysts, and HFC evaluation. In any case, it would be appropriate to remove the implant when fracture fixation is reached.

KW - Fracture fixation device

KW - Genotoxicity

KW - Metal ions

KW - Sister chromatid exchange

KW - Stainless steel

UR - http://www.scopus.com/inward/record.url?scp=18344406592&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=18344406592&partnerID=8YFLogxK

U2 - 10.1002/(SICI)1097-4636(200004)50:1<21::AID-JBM4>3.0.CO;2-R

DO - 10.1002/(SICI)1097-4636(200004)50:1<21::AID-JBM4>3.0.CO;2-R

M3 - Article

C2 - 10644959

AN - SCOPUS:18344406592

VL - 50

SP - 21

EP - 26

JO - Journal of Biomedical Materials Research - Part A

JF - Journal of Biomedical Materials Research - Part A

SN - 1549-3296

IS - 1

ER -