Specimen-specific modeling of hip fracture pattern and repair

Azhar A. Ali, Luca Cristofolini, Enrico Schileo, Haixiang Hu, Fulvia Taddei, Raymond H. Kim, Paul J. Rullkoetter, Peter J. Laz

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

Hip fracture remains a major health problem for the elderly. Clinical studies have assessed fracture risk based on bone quality in the aging population and cadaveric testing has quantified bone strength and fracture loads. Prior modeling has primarily focused on quantifying the strain distribution in bone as an indicator of fracture risk. Recent advances in the extended finite element method (XFEM) enable prediction of the initiation and propagation of cracks without requiring a priori knowledge of the crack path. Accordingly, the objectives of this study were to predict femoral fracture in specimen-specific models using the XFEM approach, to perform one-to-one comparisons of predicted and in vitro fracture patterns, and to develop a framework to assess the mechanics and load transfer in the fractured femur when it is repaired with an osteosynthesis implant. Five specimen-specific femur models were developed from in vitro experiments under a simulated stance loading condition. Predicted fracture patterns closely matched the in vitro patterns; however, predictions of fracture load differed by approximately 50% due to sensitivity to local material properties. Specimen-specific intertrochanteric fractures were induced by subjecting the femur models to a sideways fall and repaired with a contemporary implant. Under a post-surgical stance loading, model-predicted load sharing between the implant and bone across the fracture surface varied from 59%:41% to 89%:11%, underscoring the importance of considering anatomic and fracture variability in the evaluation of implants. XFEM modeling shows potential as a macro-level analysis enabling fracture investigations of clinical cohorts, including at-risk groups, and the design of robust implants.

Original languageEnglish
Pages (from-to)536-543
Number of pages8
JournalJournal of Biomechanics
Volume47
Issue number2
DOIs
Publication statusPublished - Jan 22 2014

Fingerprint

Hip Fractures
Femur
Repair
Bone Fractures
Bone and Bones
Femoral Fractures
Mechanics
Bone
Health
Population
In Vitro Techniques
Cracks
Medical problems
Macros
Materials properties
Aging of materials

Keywords

  • Bone fracture
  • Extended finite element method (XFEM)
  • Femur
  • Finite element
  • Hip fracture
  • Osteosynthesis

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Rehabilitation
  • Biophysics
  • Biomedical Engineering

Cite this

Specimen-specific modeling of hip fracture pattern and repair. / Ali, Azhar A.; Cristofolini, Luca; Schileo, Enrico; Hu, Haixiang; Taddei, Fulvia; Kim, Raymond H.; Rullkoetter, Paul J.; Laz, Peter J.

In: Journal of Biomechanics, Vol. 47, No. 2, 22.01.2014, p. 536-543.

Research output: Contribution to journalArticle

Ali, AA, Cristofolini, L, Schileo, E, Hu, H, Taddei, F, Kim, RH, Rullkoetter, PJ & Laz, PJ 2014, 'Specimen-specific modeling of hip fracture pattern and repair', Journal of Biomechanics, vol. 47, no. 2, pp. 536-543. https://doi.org/10.1016/j.jbiomech.2013.10.033
Ali, Azhar A. ; Cristofolini, Luca ; Schileo, Enrico ; Hu, Haixiang ; Taddei, Fulvia ; Kim, Raymond H. ; Rullkoetter, Paul J. ; Laz, Peter J. / Specimen-specific modeling of hip fracture pattern and repair. In: Journal of Biomechanics. 2014 ; Vol. 47, No. 2. pp. 536-543.
@article{9645d84a4fb64c9786c1992e9a17b4e6,
title = "Specimen-specific modeling of hip fracture pattern and repair",
abstract = "Hip fracture remains a major health problem for the elderly. Clinical studies have assessed fracture risk based on bone quality in the aging population and cadaveric testing has quantified bone strength and fracture loads. Prior modeling has primarily focused on quantifying the strain distribution in bone as an indicator of fracture risk. Recent advances in the extended finite element method (XFEM) enable prediction of the initiation and propagation of cracks without requiring a priori knowledge of the crack path. Accordingly, the objectives of this study were to predict femoral fracture in specimen-specific models using the XFEM approach, to perform one-to-one comparisons of predicted and in vitro fracture patterns, and to develop a framework to assess the mechanics and load transfer in the fractured femur when it is repaired with an osteosynthesis implant. Five specimen-specific femur models were developed from in vitro experiments under a simulated stance loading condition. Predicted fracture patterns closely matched the in vitro patterns; however, predictions of fracture load differed by approximately 50{\%} due to sensitivity to local material properties. Specimen-specific intertrochanteric fractures were induced by subjecting the femur models to a sideways fall and repaired with a contemporary implant. Under a post-surgical stance loading, model-predicted load sharing between the implant and bone across the fracture surface varied from 59{\%}:41{\%} to 89{\%}:11{\%}, underscoring the importance of considering anatomic and fracture variability in the evaluation of implants. XFEM modeling shows potential as a macro-level analysis enabling fracture investigations of clinical cohorts, including at-risk groups, and the design of robust implants.",
keywords = "Bone fracture, Extended finite element method (XFEM), Femur, Finite element, Hip fracture, Osteosynthesis",
author = "Ali, {Azhar A.} and Luca Cristofolini and Enrico Schileo and Haixiang Hu and Fulvia Taddei and Kim, {Raymond H.} and Rullkoetter, {Paul J.} and Laz, {Peter J.}",
year = "2014",
month = "1",
day = "22",
doi = "10.1016/j.jbiomech.2013.10.033",
language = "English",
volume = "47",
pages = "536--543",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Limited",
number = "2",

}

TY - JOUR

T1 - Specimen-specific modeling of hip fracture pattern and repair

AU - Ali, Azhar A.

AU - Cristofolini, Luca

AU - Schileo, Enrico

AU - Hu, Haixiang

AU - Taddei, Fulvia

AU - Kim, Raymond H.

AU - Rullkoetter, Paul J.

AU - Laz, Peter J.

PY - 2014/1/22

Y1 - 2014/1/22

N2 - Hip fracture remains a major health problem for the elderly. Clinical studies have assessed fracture risk based on bone quality in the aging population and cadaveric testing has quantified bone strength and fracture loads. Prior modeling has primarily focused on quantifying the strain distribution in bone as an indicator of fracture risk. Recent advances in the extended finite element method (XFEM) enable prediction of the initiation and propagation of cracks without requiring a priori knowledge of the crack path. Accordingly, the objectives of this study were to predict femoral fracture in specimen-specific models using the XFEM approach, to perform one-to-one comparisons of predicted and in vitro fracture patterns, and to develop a framework to assess the mechanics and load transfer in the fractured femur when it is repaired with an osteosynthesis implant. Five specimen-specific femur models were developed from in vitro experiments under a simulated stance loading condition. Predicted fracture patterns closely matched the in vitro patterns; however, predictions of fracture load differed by approximately 50% due to sensitivity to local material properties. Specimen-specific intertrochanteric fractures were induced by subjecting the femur models to a sideways fall and repaired with a contemporary implant. Under a post-surgical stance loading, model-predicted load sharing between the implant and bone across the fracture surface varied from 59%:41% to 89%:11%, underscoring the importance of considering anatomic and fracture variability in the evaluation of implants. XFEM modeling shows potential as a macro-level analysis enabling fracture investigations of clinical cohorts, including at-risk groups, and the design of robust implants.

AB - Hip fracture remains a major health problem for the elderly. Clinical studies have assessed fracture risk based on bone quality in the aging population and cadaveric testing has quantified bone strength and fracture loads. Prior modeling has primarily focused on quantifying the strain distribution in bone as an indicator of fracture risk. Recent advances in the extended finite element method (XFEM) enable prediction of the initiation and propagation of cracks without requiring a priori knowledge of the crack path. Accordingly, the objectives of this study were to predict femoral fracture in specimen-specific models using the XFEM approach, to perform one-to-one comparisons of predicted and in vitro fracture patterns, and to develop a framework to assess the mechanics and load transfer in the fractured femur when it is repaired with an osteosynthesis implant. Five specimen-specific femur models were developed from in vitro experiments under a simulated stance loading condition. Predicted fracture patterns closely matched the in vitro patterns; however, predictions of fracture load differed by approximately 50% due to sensitivity to local material properties. Specimen-specific intertrochanteric fractures were induced by subjecting the femur models to a sideways fall and repaired with a contemporary implant. Under a post-surgical stance loading, model-predicted load sharing between the implant and bone across the fracture surface varied from 59%:41% to 89%:11%, underscoring the importance of considering anatomic and fracture variability in the evaluation of implants. XFEM modeling shows potential as a macro-level analysis enabling fracture investigations of clinical cohorts, including at-risk groups, and the design of robust implants.

KW - Bone fracture

KW - Extended finite element method (XFEM)

KW - Femur

KW - Finite element

KW - Hip fracture

KW - Osteosynthesis

UR - http://www.scopus.com/inward/record.url?scp=84891837055&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84891837055&partnerID=8YFLogxK

U2 - 10.1016/j.jbiomech.2013.10.033

DO - 10.1016/j.jbiomech.2013.10.033

M3 - Article

VL - 47

SP - 536

EP - 543

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290

IS - 2

ER -