RADIOGRAFIA DIGITALE CON FOSFORI. DOSE E QUALITA DELLE IMMAGINI

Translated title of the contribution: Storage phosphor radiography. Exposure dose and image quality

E. Salvini, G. Pedroli, G. Montanari, R. Pastori, A. Crespi, G. Zincone

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Digital radiography (DR) based on storage phosphor technology is progressively replacing conventional screen-film system radiographic techniques (CR). However, many questions about image quality and dose reduction are still open. Thus, since DR spatial resolution is always lower than that of high quality screen-film images and image noise is conversely higher, for general radiography examinations especially, the signal-to-noise ratio is always lower with DR than with CR at the same dose level. However, the wide dynamic range, the linear response of storage phosphor detectors and the automatic read-out control of the digital system, enable lower DR X-ray imaging efficiency to be overcome, producing a nearly perfect read-out of the image data every time an exposure is made. Moreover, post-processing can make the detection of abnormalities easier. This is why in many ROC clinical accuracy studies DR performed equally or better than CR. Good quality DR images, similar to conventional ones at the same dose levels, are therefore achievable in chest, abdomen, bone and soft-tissues examinations. Dose evaluation protocols are strongly needed in DR since overexposures due to technical mistakes may be overlooked; moreover, doses can be adjusted to the peculiar diagnostic need. The S values shown on any hard-copy image can be used to this purpose, even though it must be pointed out that they do not express the actual mean dose to the detector.

Original languageItalian
Pages (from-to)847-851
Number of pages5
JournalRadiologia Medica
Volume87
Issue number6
Publication statusPublished - 1994

Fingerprint

Radiographic Image Enhancement
Radiography
X-Ray Film
Signal-To-Noise Ratio
Motion Pictures
Abdomen
Thorax
X-Rays
Technology
Bone and Bones

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Salvini, E., Pedroli, G., Montanari, G., Pastori, R., Crespi, A., & Zincone, G. (1994). RADIOGRAFIA DIGITALE CON FOSFORI. DOSE E QUALITA DELLE IMMAGINI. Radiologia Medica, 87(6), 847-851.

RADIOGRAFIA DIGITALE CON FOSFORI. DOSE E QUALITA DELLE IMMAGINI. / Salvini, E.; Pedroli, G.; Montanari, G.; Pastori, R.; Crespi, A.; Zincone, G.

In: Radiologia Medica, Vol. 87, No. 6, 1994, p. 847-851.

Research output: Contribution to journalArticle

Salvini, E, Pedroli, G, Montanari, G, Pastori, R, Crespi, A & Zincone, G 1994, 'RADIOGRAFIA DIGITALE CON FOSFORI. DOSE E QUALITA DELLE IMMAGINI', Radiologia Medica, vol. 87, no. 6, pp. 847-851.
Salvini E, Pedroli G, Montanari G, Pastori R, Crespi A, Zincone G. RADIOGRAFIA DIGITALE CON FOSFORI. DOSE E QUALITA DELLE IMMAGINI. Radiologia Medica. 1994;87(6):847-851.
Salvini, E. ; Pedroli, G. ; Montanari, G. ; Pastori, R. ; Crespi, A. ; Zincone, G. / RADIOGRAFIA DIGITALE CON FOSFORI. DOSE E QUALITA DELLE IMMAGINI. In: Radiologia Medica. 1994 ; Vol. 87, No. 6. pp. 847-851.
@article{8acb77bb4c0344f18d1868350882cea5,
title = "RADIOGRAFIA DIGITALE CON FOSFORI. DOSE E QUALITA DELLE IMMAGINI",
abstract = "Digital radiography (DR) based on storage phosphor technology is progressively replacing conventional screen-film system radiographic techniques (CR). However, many questions about image quality and dose reduction are still open. Thus, since DR spatial resolution is always lower than that of high quality screen-film images and image noise is conversely higher, for general radiography examinations especially, the signal-to-noise ratio is always lower with DR than with CR at the same dose level. However, the wide dynamic range, the linear response of storage phosphor detectors and the automatic read-out control of the digital system, enable lower DR X-ray imaging efficiency to be overcome, producing a nearly perfect read-out of the image data every time an exposure is made. Moreover, post-processing can make the detection of abnormalities easier. This is why in many ROC clinical accuracy studies DR performed equally or better than CR. Good quality DR images, similar to conventional ones at the same dose levels, are therefore achievable in chest, abdomen, bone and soft-tissues examinations. Dose evaluation protocols are strongly needed in DR since overexposures due to technical mistakes may be overlooked; moreover, doses can be adjusted to the peculiar diagnostic need. The S values shown on any hard-copy image can be used to this purpose, even though it must be pointed out that they do not express the actual mean dose to the detector.",
keywords = "image quality, radiation dose, radiography, storage phosphor",
author = "E. Salvini and G. Pedroli and G. Montanari and R. Pastori and A. Crespi and G. Zincone",
year = "1994",
language = "Italian",
volume = "87",
pages = "847--851",
journal = "Radiologia Medica",
issn = "0033-8362",
publisher = "Springer-Verlag Italia s.r.l.",
number = "6",

}

TY - JOUR

T1 - RADIOGRAFIA DIGITALE CON FOSFORI. DOSE E QUALITA DELLE IMMAGINI

AU - Salvini, E.

AU - Pedroli, G.

AU - Montanari, G.

AU - Pastori, R.

AU - Crespi, A.

AU - Zincone, G.

PY - 1994

Y1 - 1994

N2 - Digital radiography (DR) based on storage phosphor technology is progressively replacing conventional screen-film system radiographic techniques (CR). However, many questions about image quality and dose reduction are still open. Thus, since DR spatial resolution is always lower than that of high quality screen-film images and image noise is conversely higher, for general radiography examinations especially, the signal-to-noise ratio is always lower with DR than with CR at the same dose level. However, the wide dynamic range, the linear response of storage phosphor detectors and the automatic read-out control of the digital system, enable lower DR X-ray imaging efficiency to be overcome, producing a nearly perfect read-out of the image data every time an exposure is made. Moreover, post-processing can make the detection of abnormalities easier. This is why in many ROC clinical accuracy studies DR performed equally or better than CR. Good quality DR images, similar to conventional ones at the same dose levels, are therefore achievable in chest, abdomen, bone and soft-tissues examinations. Dose evaluation protocols are strongly needed in DR since overexposures due to technical mistakes may be overlooked; moreover, doses can be adjusted to the peculiar diagnostic need. The S values shown on any hard-copy image can be used to this purpose, even though it must be pointed out that they do not express the actual mean dose to the detector.

AB - Digital radiography (DR) based on storage phosphor technology is progressively replacing conventional screen-film system radiographic techniques (CR). However, many questions about image quality and dose reduction are still open. Thus, since DR spatial resolution is always lower than that of high quality screen-film images and image noise is conversely higher, for general radiography examinations especially, the signal-to-noise ratio is always lower with DR than with CR at the same dose level. However, the wide dynamic range, the linear response of storage phosphor detectors and the automatic read-out control of the digital system, enable lower DR X-ray imaging efficiency to be overcome, producing a nearly perfect read-out of the image data every time an exposure is made. Moreover, post-processing can make the detection of abnormalities easier. This is why in many ROC clinical accuracy studies DR performed equally or better than CR. Good quality DR images, similar to conventional ones at the same dose levels, are therefore achievable in chest, abdomen, bone and soft-tissues examinations. Dose evaluation protocols are strongly needed in DR since overexposures due to technical mistakes may be overlooked; moreover, doses can be adjusted to the peculiar diagnostic need. The S values shown on any hard-copy image can be used to this purpose, even though it must be pointed out that they do not express the actual mean dose to the detector.

KW - image quality

KW - radiation dose

KW - radiography, storage phosphor

UR - http://www.scopus.com/inward/record.url?scp=0028129012&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028129012&partnerID=8YFLogxK

M3 - Articolo

C2 - 8041940

AN - SCOPUS:0028129012

VL - 87

SP - 847

EP - 851

JO - Radiologia Medica

JF - Radiologia Medica

SN - 0033-8362

IS - 6

ER -