99mTc-MIBI scintimammography using a dedicated nuclear mammograph

Carlo L. Maini, Francesco De Notaristefani, Anna Tofani, Francesca Iacopi, Rosa Sciuto, Alessandro Semprebene, Tiziana Malatesta, Franco Vittori, Fabrizio Frezza, Claudio Botti, Salvatore Giunta, Pier Giorgio Natali

Research output: Contribution to journalArticle

31 Citations (Scopus)

Abstract

This study reports on a prototype single-photon emission mammograph (SPEM) dedicated to 99mTc-hexakis-2-methoxyisobutile isonitrile (MIBI) scintimammography. Main technical features are reported together with physical performance. Preliminary patient data are also reported. Methods: The SPEM detector head is composed of a Csl(T1) scintillating array coupled to a Hamamatsu R3292 position-sensitive photomultiplier tube with crossed- wire anode. The high-resolution collimator is 35-mm thick with a 1.7-mm hole diameter and a 0.2-mm septal thickness. The electronic acquisition system is composed of five integrated cards with computation based on high-speed programmable microprocessors. The readout electronics include correction maps for on-line energy correction and spatial uniformity. The small size of the detector head allows the use of mechanical breast compression to minimize detection distance and tissue scatter. After physical SPEM performance evaluation in vivo scintimammography was performed in 29 patients and was compared with a state-of-the-art Anger camera. Results: The SPEM showed an intrinsic spatial resolution of 2 mm, an energy resolution of 23% FWHM at 122 keV and spatial uniformities of 18% (integral) and 13.5% (differential). The SPEM imaged one 0.4-cm carcinoma missed by the Anger camera and resolved as separate lumps an irregular focal uptake on the Anger camera image. The remaining cases yielded concordant results. Conclusion: The SPEM prototype presented in this study shows adequate physical characteristics for 99mTc- MIBI scintimammography.

Original languageEnglish
Pages (from-to)46-51
Number of pages6
JournalJournal of Nuclear Medicine
Volume40
Issue number1
Publication statusPublished - Jan 1999

Fingerprint

Photons
Anger
Head
Microcomputers
Electrodes
Breast
Carcinoma

Keywords

  • Tc-hexakis-2-methoxyisobutyl isonitrile
  • Imaging device
  • Scintimammography

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Maini, C. L., De Notaristefani, F., Tofani, A., Iacopi, F., Sciuto, R., Semprebene, A., ... Natali, P. G. (1999). 99mTc-MIBI scintimammography using a dedicated nuclear mammograph. Journal of Nuclear Medicine, 40(1), 46-51.

99mTc-MIBI scintimammography using a dedicated nuclear mammograph. / Maini, Carlo L.; De Notaristefani, Francesco; Tofani, Anna; Iacopi, Francesca; Sciuto, Rosa; Semprebene, Alessandro; Malatesta, Tiziana; Vittori, Franco; Frezza, Fabrizio; Botti, Claudio; Giunta, Salvatore; Natali, Pier Giorgio.

In: Journal of Nuclear Medicine, Vol. 40, No. 1, 01.1999, p. 46-51.

Research output: Contribution to journalArticle

Maini, CL, De Notaristefani, F, Tofani, A, Iacopi, F, Sciuto, R, Semprebene, A, Malatesta, T, Vittori, F, Frezza, F, Botti, C, Giunta, S & Natali, PG 1999, '99mTc-MIBI scintimammography using a dedicated nuclear mammograph', Journal of Nuclear Medicine, vol. 40, no. 1, pp. 46-51.
Maini CL, De Notaristefani F, Tofani A, Iacopi F, Sciuto R, Semprebene A et al. 99mTc-MIBI scintimammography using a dedicated nuclear mammograph. Journal of Nuclear Medicine. 1999 Jan;40(1):46-51.
Maini, Carlo L. ; De Notaristefani, Francesco ; Tofani, Anna ; Iacopi, Francesca ; Sciuto, Rosa ; Semprebene, Alessandro ; Malatesta, Tiziana ; Vittori, Franco ; Frezza, Fabrizio ; Botti, Claudio ; Giunta, Salvatore ; Natali, Pier Giorgio. / 99mTc-MIBI scintimammography using a dedicated nuclear mammograph. In: Journal of Nuclear Medicine. 1999 ; Vol. 40, No. 1. pp. 46-51.
@article{5c8d26f2aacb4d87bac5375070dc4f7a,
title = "99mTc-MIBI scintimammography using a dedicated nuclear mammograph",
abstract = "This study reports on a prototype single-photon emission mammograph (SPEM) dedicated to 99mTc-hexakis-2-methoxyisobutile isonitrile (MIBI) scintimammography. Main technical features are reported together with physical performance. Preliminary patient data are also reported. Methods: The SPEM detector head is composed of a Csl(T1) scintillating array coupled to a Hamamatsu R3292 position-sensitive photomultiplier tube with crossed- wire anode. The high-resolution collimator is 35-mm thick with a 1.7-mm hole diameter and a 0.2-mm septal thickness. The electronic acquisition system is composed of five integrated cards with computation based on high-speed programmable microprocessors. The readout electronics include correction maps for on-line energy correction and spatial uniformity. The small size of the detector head allows the use of mechanical breast compression to minimize detection distance and tissue scatter. After physical SPEM performance evaluation in vivo scintimammography was performed in 29 patients and was compared with a state-of-the-art Anger camera. Results: The SPEM showed an intrinsic spatial resolution of 2 mm, an energy resolution of 23{\%} FWHM at 122 keV and spatial uniformities of 18{\%} (integral) and 13.5{\%} (differential). The SPEM imaged one 0.4-cm carcinoma missed by the Anger camera and resolved as separate lumps an irregular focal uptake on the Anger camera image. The remaining cases yielded concordant results. Conclusion: The SPEM prototype presented in this study shows adequate physical characteristics for 99mTc- MIBI scintimammography.",
keywords = "Tc-hexakis-2-methoxyisobutyl isonitrile, Imaging device, Scintimammography",
author = "Maini, {Carlo L.} and {De Notaristefani}, Francesco and Anna Tofani and Francesca Iacopi and Rosa Sciuto and Alessandro Semprebene and Tiziana Malatesta and Franco Vittori and Fabrizio Frezza and Claudio Botti and Salvatore Giunta and Natali, {Pier Giorgio}",
year = "1999",
month = "1",
language = "English",
volume = "40",
pages = "46--51",
journal = "Journal of Nuclear Medicine",
issn = "0161-5505",
publisher = "Society of Nuclear Medicine Inc.",
number = "1",

}

TY - JOUR

T1 - 99mTc-MIBI scintimammography using a dedicated nuclear mammograph

AU - Maini, Carlo L.

AU - De Notaristefani, Francesco

AU - Tofani, Anna

AU - Iacopi, Francesca

AU - Sciuto, Rosa

AU - Semprebene, Alessandro

AU - Malatesta, Tiziana

AU - Vittori, Franco

AU - Frezza, Fabrizio

AU - Botti, Claudio

AU - Giunta, Salvatore

AU - Natali, Pier Giorgio

PY - 1999/1

Y1 - 1999/1

N2 - This study reports on a prototype single-photon emission mammograph (SPEM) dedicated to 99mTc-hexakis-2-methoxyisobutile isonitrile (MIBI) scintimammography. Main technical features are reported together with physical performance. Preliminary patient data are also reported. Methods: The SPEM detector head is composed of a Csl(T1) scintillating array coupled to a Hamamatsu R3292 position-sensitive photomultiplier tube with crossed- wire anode. The high-resolution collimator is 35-mm thick with a 1.7-mm hole diameter and a 0.2-mm septal thickness. The electronic acquisition system is composed of five integrated cards with computation based on high-speed programmable microprocessors. The readout electronics include correction maps for on-line energy correction and spatial uniformity. The small size of the detector head allows the use of mechanical breast compression to minimize detection distance and tissue scatter. After physical SPEM performance evaluation in vivo scintimammography was performed in 29 patients and was compared with a state-of-the-art Anger camera. Results: The SPEM showed an intrinsic spatial resolution of 2 mm, an energy resolution of 23% FWHM at 122 keV and spatial uniformities of 18% (integral) and 13.5% (differential). The SPEM imaged one 0.4-cm carcinoma missed by the Anger camera and resolved as separate lumps an irregular focal uptake on the Anger camera image. The remaining cases yielded concordant results. Conclusion: The SPEM prototype presented in this study shows adequate physical characteristics for 99mTc- MIBI scintimammography.

AB - This study reports on a prototype single-photon emission mammograph (SPEM) dedicated to 99mTc-hexakis-2-methoxyisobutile isonitrile (MIBI) scintimammography. Main technical features are reported together with physical performance. Preliminary patient data are also reported. Methods: The SPEM detector head is composed of a Csl(T1) scintillating array coupled to a Hamamatsu R3292 position-sensitive photomultiplier tube with crossed- wire anode. The high-resolution collimator is 35-mm thick with a 1.7-mm hole diameter and a 0.2-mm septal thickness. The electronic acquisition system is composed of five integrated cards with computation based on high-speed programmable microprocessors. The readout electronics include correction maps for on-line energy correction and spatial uniformity. The small size of the detector head allows the use of mechanical breast compression to minimize detection distance and tissue scatter. After physical SPEM performance evaluation in vivo scintimammography was performed in 29 patients and was compared with a state-of-the-art Anger camera. Results: The SPEM showed an intrinsic spatial resolution of 2 mm, an energy resolution of 23% FWHM at 122 keV and spatial uniformities of 18% (integral) and 13.5% (differential). The SPEM imaged one 0.4-cm carcinoma missed by the Anger camera and resolved as separate lumps an irregular focal uptake on the Anger camera image. The remaining cases yielded concordant results. Conclusion: The SPEM prototype presented in this study shows adequate physical characteristics for 99mTc- MIBI scintimammography.

KW - Tc-hexakis-2-methoxyisobutyl isonitrile

KW - Imaging device

KW - Scintimammography

UR - http://www.scopus.com/inward/record.url?scp=0032587211&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032587211&partnerID=8YFLogxK

M3 - Article

VL - 40

SP - 46

EP - 51

JO - Journal of Nuclear Medicine

JF - Journal of Nuclear Medicine

SN - 0161-5505

IS - 1

ER -