Surgical Treatment of Mediastinitis with Omentoplasty in Ventricular Assist Device Patients: Report of Referral Center Experience

Marina Pieri, Marcus Müller, Anna Mara Scandroglio, Panagiotis Pergantis, Alexandra Kretzschmar, Friedrich Kaufmann, Volkmar Falk, Thomas Krabatsch, Georg Arlt, Evgenij Potapov, Marian Kukucka

Research output: Contribution to journalArticlepeer-review

Abstract

Mediastinitis is more frequent in patients with implantable ventricular assist devices (VADs) than in other cardiac surgery patients and carries significant mortality. We report our experience with a stepwise approach including aggressive debridement, jet lavage, vacuum assisted closure dressing, and finally coverage with well-vascularized and immune-active omental flaps in VAD patients with infective mediastinitis. We retrospectively collected and analyzed data of patients with continuous flow VAD who underwent plasty with the omental flap because of mediastinitis at Deutsches Herzzentrum Berlin between January 1, 2008 and October 30, 2015. Eight hundred forty-five patients underwent VAD implantation during the study period. Omentoplasty due to infective mediastinitis was performed in 17 cases. Nine had a HeartWare HVAD as left ventricular assist device (LVAD), three patients had two Heart-Ware HVAD as biventricular assist device (BIVAD), four had a HeartMate II LVAD device, and one patient had a Berlin Heart Incor LVAD. The microorganisms most frequently isolated from the sternal wound were Gram-positive Staphylococcus spp. Four cases of bleeding requiring surgical revision were recorded: three of intraabdominal and one of wound bleeding. Eight patients (47%) survived, whereas the other nine patients (53%) died. Sixteen (94%) required intensive care unit admission, and median hospital stay was 21 (1-182) days. Postoperative renal failure requiring dialysis and septic shock requiring vasopressors were associated with hospital mortality (p = 0.009 and p = 0.05, respectively). Early surgical treatment of mediastinitis after VAD implantation with omentoplasty is a valuable strategy in an otherwise dead-end situation. Bleeding should be meticulously controlled in these anticoagulated and fragile patients.
Original languageEnglish
Pages (from-to)666 - 670
Number of pages5
JournalASAIO Journal
Volume62
Issue number6
DOIs
Publication statusPublished - Oct 1 2016

Keywords

  • mediastinitis
  • mortality
  • omentoplasty
  • ventricular assist device

ASJC Scopus subject areas

  • Bioengineering
  • Biophysics
  • Medicine(all)
  • Biomaterials
  • Biomedical Engineering

Fingerprint Dive into the research topics of 'Surgical Treatment of Mediastinitis with Omentoplasty in Ventricular Assist Device Patients: Report of Referral Center Experience'. Together they form a unique fingerprint.

Cite this