Il trattamento delle fratture esposte d'arma da fuoco: Presentazione di due casi clinici

Translated title of the contribution: Surgical treatment of open gunshot fractures. Two case reports

A. Garbuglia, C. Ronzani, M. Citterio, M. Sallusti, D. Bazzoni, T. Donzelli, C. E. Bossi

Research output: Contribution to journalArticle

Abstract

Preliminary results of the use in open gunshot fractures of external fixator are presented. Based on the encouraging results of two clinical application in multiple severely comminuted gunshot-shelling fractures of the lower limbs, this paper underlines the main role of dynamic stabilization of the fractures site, thus avoiding the disadvantages previously experienced with rigid traditional external fixators.

Original languageItalian
Pages (from-to)35-38
Number of pages4
JournalMinerva Ortopedica e Traumatologica
Volume51
Issue number1
Publication statusPublished - 2000

Fingerprint

External Fixators
Open Fractures
Lower Extremity

ASJC Scopus subject areas

  • Surgery

Cite this

Garbuglia, A., Ronzani, C., Citterio, M., Sallusti, M., Bazzoni, D., Donzelli, T., & Bossi, C. E. (2000). Il trattamento delle fratture esposte d'arma da fuoco: Presentazione di due casi clinici. Minerva Ortopedica e Traumatologica, 51(1), 35-38.

Il trattamento delle fratture esposte d'arma da fuoco : Presentazione di due casi clinici. / Garbuglia, A.; Ronzani, C.; Citterio, M.; Sallusti, M.; Bazzoni, D.; Donzelli, T.; Bossi, C. E.

In: Minerva Ortopedica e Traumatologica, Vol. 51, No. 1, 2000, p. 35-38.

Research output: Contribution to journalArticle

Garbuglia, A, Ronzani, C, Citterio, M, Sallusti, M, Bazzoni, D, Donzelli, T & Bossi, CE 2000, 'Il trattamento delle fratture esposte d'arma da fuoco: Presentazione di due casi clinici', Minerva Ortopedica e Traumatologica, vol. 51, no. 1, pp. 35-38.
Garbuglia, A. ; Ronzani, C. ; Citterio, M. ; Sallusti, M. ; Bazzoni, D. ; Donzelli, T. ; Bossi, C. E. / Il trattamento delle fratture esposte d'arma da fuoco : Presentazione di due casi clinici. In: Minerva Ortopedica e Traumatologica. 2000 ; Vol. 51, No. 1. pp. 35-38.
@article{8a80b3603f104faab4ed040759eb5540,
title = "Il trattamento delle fratture esposte d'arma da fuoco: Presentazione di due casi clinici",
abstract = "Preliminary results of the use in open gunshot fractures of external fixator are presented. Based on the encouraging results of two clinical application in multiple severely comminuted gunshot-shelling fractures of the lower limbs, this paper underlines the main role of dynamic stabilization of the fractures site, thus avoiding the disadvantages previously experienced with rigid traditional external fixators.",
keywords = "External fixators, Fracture fixation, methods, Open gunshot fractures, Tibial fractures, Wounds gunshot femoral fractures",
author = "A. Garbuglia and C. Ronzani and M. Citterio and M. Sallusti and D. Bazzoni and T. Donzelli and Bossi, {C. E.}",
year = "2000",
language = "Italian",
volume = "51",
pages = "35--38",
journal = "Minerva Ortopedica",
issn = "0026-4911",
publisher = "Edizioni Minerva Medica S.p.A.",
number = "1",

}

TY - JOUR

T1 - Il trattamento delle fratture esposte d'arma da fuoco

T2 - Presentazione di due casi clinici

AU - Garbuglia, A.

AU - Ronzani, C.

AU - Citterio, M.

AU - Sallusti, M.

AU - Bazzoni, D.

AU - Donzelli, T.

AU - Bossi, C. E.

PY - 2000

Y1 - 2000

N2 - Preliminary results of the use in open gunshot fractures of external fixator are presented. Based on the encouraging results of two clinical application in multiple severely comminuted gunshot-shelling fractures of the lower limbs, this paper underlines the main role of dynamic stabilization of the fractures site, thus avoiding the disadvantages previously experienced with rigid traditional external fixators.

AB - Preliminary results of the use in open gunshot fractures of external fixator are presented. Based on the encouraging results of two clinical application in multiple severely comminuted gunshot-shelling fractures of the lower limbs, this paper underlines the main role of dynamic stabilization of the fractures site, thus avoiding the disadvantages previously experienced with rigid traditional external fixators.

KW - External fixators

KW - Fracture fixation, methods

KW - Open gunshot fractures

KW - Tibial fractures

KW - Wounds gunshot femoral fractures

UR - http://www.scopus.com/inward/record.url?scp=0033860005&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033860005&partnerID=8YFLogxK

M3 - Articolo

AN - SCOPUS:0033860005

VL - 51

SP - 35

EP - 38

JO - Minerva Ortopedica

JF - Minerva Ortopedica

SN - 0026-4911

IS - 1

ER -