TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

Marie Paule Garcia, Erin McKay, Daphnée Villoing, Ludovic Ferrer, Marta Cremonesi, Francesca Botta, Mahila Ferrari, Manuel Bardiès

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest. com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user's imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan. therapeutical treatment was implemented using the 4D XCAT model. Whole-body "step and shoot" acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan.kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.

Original languageEnglish
Pages (from-to)6885-6894
Number of pages10
JournalMedical Physics
Volume42
Issue number12
DOIs
Publication statusPublished - Dec 1 2015

Fingerprint

Gamma Cameras
Nuclear Medicine
Software
Pharmacokinetics
Clinical Protocols
Single-Photon Emission-Computed Tomography
Radiopharmaceuticals
Positron-Emission Tomography
Databases
pentetreotide
Therapeutics

Keywords

  • dosimetry
  • GATE
  • Monte Carlo simulations
  • nuclear medicine
  • SPECT

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

TestDose : A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry. / Garcia, Marie Paule; McKay, Erin; Villoing, Daphnée; Ferrer, Ludovic; Cremonesi, Marta; Botta, Francesca; Ferrari, Mahila; Bardiès, Manuel.

In: Medical Physics, Vol. 42, No. 12, 01.12.2015, p. 6885-6894.

Research output: Contribution to journalArticle

Garcia, Marie Paule ; McKay, Erin ; Villoing, Daphnée ; Ferrer, Ludovic ; Cremonesi, Marta ; Botta, Francesca ; Ferrari, Mahila ; Bardiès, Manuel. / TestDose : A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry. In: Medical Physics. 2015 ; Vol. 42, No. 12. pp. 6885-6894.
@article{ef9a5a7c6ae4432e8247f017a980d036,
title = "TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry",
abstract = "Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest. com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user's imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan. therapeutical treatment was implemented using the 4D XCAT model. Whole-body {"}step and shoot{"} acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan.kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.",
keywords = "dosimetry, GATE, Monte Carlo simulations, nuclear medicine, SPECT",
author = "Garcia, {Marie Paule} and Erin McKay and Daphn{\'e}e Villoing and Ludovic Ferrer and Marta Cremonesi and Francesca Botta and Mahila Ferrari and Manuel Bardi{\`e}s",
year = "2015",
month = "12",
day = "1",
doi = "10.1118/1.4934828",
language = "English",
volume = "42",
pages = "6885--6894",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "John Wiley and Sons Ltd",
number = "12",

}

TY - JOUR

T1 - TestDose

T2 - A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

AU - Garcia, Marie Paule

AU - McKay, Erin

AU - Villoing, Daphnée

AU - Ferrer, Ludovic

AU - Cremonesi, Marta

AU - Botta, Francesca

AU - Ferrari, Mahila

AU - Bardiès, Manuel

PY - 2015/12/1

Y1 - 2015/12/1

N2 - Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest. com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user's imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan. therapeutical treatment was implemented using the 4D XCAT model. Whole-body "step and shoot" acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan.kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.

AB - Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest. com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user's imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan. therapeutical treatment was implemented using the 4D XCAT model. Whole-body "step and shoot" acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan.kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.

KW - dosimetry

KW - GATE

KW - Monte Carlo simulations

KW - nuclear medicine

KW - SPECT

UR - http://www.scopus.com/inward/record.url?scp=84947475118&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84947475118&partnerID=8YFLogxK

U2 - 10.1118/1.4934828

DO - 10.1118/1.4934828

M3 - Article

C2 - 26632045

AN - SCOPUS:84947475118

VL - 42

SP - 6885

EP - 6894

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 12

ER -