Il bilancio idrico nel malato di terapia intensiva

Translated title of the contribution: The fluid balance in the critically ill patient

Paola Bruzzone, D. Chiumello, P. Altavilla, G. Saia, F. Scopacasa, L. Gattinoni

Research output: Contribution to journalArticle

Abstract

Aim. In the critically ill patient the hemodynamic management is essential. Usually the hemodynamic status is estimated by the measurement of the intravascular pressure or volume and by computing the fluid balance, while the change in body weight estimates the total body water. The fluid balance is computed by subtracting the fluid output to the input. Although the input (fluids, drugs, infusion....) are well known, the output are difficult to correctly compute, because they depend on several factors such as the body-room temperature, amount of humidity and may change with time. Aim of this study was to prospectively evaluate the accuracy of the fluid balance compared to the body weight measured by a dedicated mattress (Hill-Rom®). Methods. Fifteen critically ill patients were enrolled (mean age of 63.2±19.7 years, body mass index of 24.9±3.5 kg/m2) and the measurements were computed every 8 hours. The data were analyzed by the Bland-Altman test. Results. Four-hundred and seventy-two measurements for a mean intensive care stay of 12.3.±7.3 days were computed. The Bland-Altamn showed a great inaccuracy, because the agreement (the difference between the 2 methods) was poor with a standard deviation of 1 840 L. Conclusion. Although the fluid balance was not accurate, the only body weight without any intravascular measurement is not helpful for a correct clinical hemodynamic management of the patient.

Original languageItalian
Pages (from-to)431-436
Number of pages6
JournalMinerva Anestesiologica
Volume70
Issue number5
Publication statusPublished - May 2004

Fingerprint

Water-Electrolyte Balance
Critical Illness
Hemodynamics
Body Weight
Body Weight Changes
Body Water
Critical Care
Humidity
Body Temperature
Body Mass Index
Pressure
Pharmaceutical Preparations

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Cite this

Bruzzone, P., Chiumello, D., Altavilla, P., Saia, G., Scopacasa, F., & Gattinoni, L. (2004). Il bilancio idrico nel malato di terapia intensiva. Minerva Anestesiologica, 70(5), 431-436.

Il bilancio idrico nel malato di terapia intensiva. / Bruzzone, Paola; Chiumello, D.; Altavilla, P.; Saia, G.; Scopacasa, F.; Gattinoni, L.

In: Minerva Anestesiologica, Vol. 70, No. 5, 05.2004, p. 431-436.

Research output: Contribution to journalArticle

Bruzzone, P, Chiumello, D, Altavilla, P, Saia, G, Scopacasa, F & Gattinoni, L 2004, 'Il bilancio idrico nel malato di terapia intensiva', Minerva Anestesiologica, vol. 70, no. 5, pp. 431-436.
Bruzzone P, Chiumello D, Altavilla P, Saia G, Scopacasa F, Gattinoni L. Il bilancio idrico nel malato di terapia intensiva. Minerva Anestesiologica. 2004 May;70(5):431-436.
Bruzzone, Paola ; Chiumello, D. ; Altavilla, P. ; Saia, G. ; Scopacasa, F. ; Gattinoni, L. / Il bilancio idrico nel malato di terapia intensiva. In: Minerva Anestesiologica. 2004 ; Vol. 70, No. 5. pp. 431-436.
@article{23dcfc815bd548f3901ae679dee34cdd,
title = "Il bilancio idrico nel malato di terapia intensiva",
abstract = "Aim. In the critically ill patient the hemodynamic management is essential. Usually the hemodynamic status is estimated by the measurement of the intravascular pressure or volume and by computing the fluid balance, while the change in body weight estimates the total body water. The fluid balance is computed by subtracting the fluid output to the input. Although the input (fluids, drugs, infusion....) are well known, the output are difficult to correctly compute, because they depend on several factors such as the body-room temperature, amount of humidity and may change with time. Aim of this study was to prospectively evaluate the accuracy of the fluid balance compared to the body weight measured by a dedicated mattress (Hill-Rom{\circledR}). Methods. Fifteen critically ill patients were enrolled (mean age of 63.2±19.7 years, body mass index of 24.9±3.5 kg/m2) and the measurements were computed every 8 hours. The data were analyzed by the Bland-Altman test. Results. Four-hundred and seventy-two measurements for a mean intensive care stay of 12.3.±7.3 days were computed. The Bland-Altamn showed a great inaccuracy, because the agreement (the difference between the 2 methods) was poor with a standard deviation of 1 840 L. Conclusion. Although the fluid balance was not accurate, the only body weight without any intravascular measurement is not helpful for a correct clinical hemodynamic management of the patient.",
keywords = "Body weight, Critically ill patients, Hemodynamics, Idric balance",
author = "Paola Bruzzone and D. Chiumello and P. Altavilla and G. Saia and F. Scopacasa and L. Gattinoni",
year = "2004",
month = "5",
language = "Italian",
volume = "70",
pages = "431--436",
journal = "Minerva Anestesiologica",
issn = "0375-9393",
publisher = "Edizioni Minerva Medica S.p.A.",
number = "5",

}

TY - JOUR

T1 - Il bilancio idrico nel malato di terapia intensiva

AU - Bruzzone, Paola

AU - Chiumello, D.

AU - Altavilla, P.

AU - Saia, G.

AU - Scopacasa, F.

AU - Gattinoni, L.

PY - 2004/5

Y1 - 2004/5

N2 - Aim. In the critically ill patient the hemodynamic management is essential. Usually the hemodynamic status is estimated by the measurement of the intravascular pressure or volume and by computing the fluid balance, while the change in body weight estimates the total body water. The fluid balance is computed by subtracting the fluid output to the input. Although the input (fluids, drugs, infusion....) are well known, the output are difficult to correctly compute, because they depend on several factors such as the body-room temperature, amount of humidity and may change with time. Aim of this study was to prospectively evaluate the accuracy of the fluid balance compared to the body weight measured by a dedicated mattress (Hill-Rom®). Methods. Fifteen critically ill patients were enrolled (mean age of 63.2±19.7 years, body mass index of 24.9±3.5 kg/m2) and the measurements were computed every 8 hours. The data were analyzed by the Bland-Altman test. Results. Four-hundred and seventy-two measurements for a mean intensive care stay of 12.3.±7.3 days were computed. The Bland-Altamn showed a great inaccuracy, because the agreement (the difference between the 2 methods) was poor with a standard deviation of 1 840 L. Conclusion. Although the fluid balance was not accurate, the only body weight without any intravascular measurement is not helpful for a correct clinical hemodynamic management of the patient.

AB - Aim. In the critically ill patient the hemodynamic management is essential. Usually the hemodynamic status is estimated by the measurement of the intravascular pressure or volume and by computing the fluid balance, while the change in body weight estimates the total body water. The fluid balance is computed by subtracting the fluid output to the input. Although the input (fluids, drugs, infusion....) are well known, the output are difficult to correctly compute, because they depend on several factors such as the body-room temperature, amount of humidity and may change with time. Aim of this study was to prospectively evaluate the accuracy of the fluid balance compared to the body weight measured by a dedicated mattress (Hill-Rom®). Methods. Fifteen critically ill patients were enrolled (mean age of 63.2±19.7 years, body mass index of 24.9±3.5 kg/m2) and the measurements were computed every 8 hours. The data were analyzed by the Bland-Altman test. Results. Four-hundred and seventy-two measurements for a mean intensive care stay of 12.3.±7.3 days were computed. The Bland-Altamn showed a great inaccuracy, because the agreement (the difference between the 2 methods) was poor with a standard deviation of 1 840 L. Conclusion. Although the fluid balance was not accurate, the only body weight without any intravascular measurement is not helpful for a correct clinical hemodynamic management of the patient.

KW - Body weight

KW - Critically ill patients

KW - Hemodynamics

KW - Idric balance

UR - http://www.scopus.com/inward/record.url?scp=3142752097&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=3142752097&partnerID=8YFLogxK

M3 - Articolo

C2 - 15181427

AN - SCOPUS:3142752097

VL - 70

SP - 431

EP - 436

JO - Minerva Anestesiologica

JF - Minerva Anestesiologica

SN - 0375-9393

IS - 5

ER -