The intelligent, painless, " germ-free" colonoscopy

A Columbus' egg for increasing population adherence to colorectal cancer screening?

Francesco Perri, Angelo Iacobellis, Marco Gentile, Emanuele Tumino, Angelo Andriulli

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Colorectal cancer (CRC) represents a major cause of morbidity and mortality. Although it is widely accepted that CRC screening in average risk populations lowers CRC incidence and mortality, a disappointedly low adherence rate to both faecal occult blood testing and colonoscopy-based screening programs has been observed in Italy and in other European countries. Main reasons for the low acceptance of colonoscopy-based CRC screening has been ascribed to lack of recommendations given by general practitioners, fear of discomfort or complications, embarrassment, and avoidance of unpleasant preparation.New advances in endoscopic technology such as colon capsule and robotic colonoscopy might represent the ideal tool for CRC screening since they reduce or eliminate procedure-related pain and discomfort. Moreover, no disinfection between procedures is required. Motion of the new probes along the gastrointestinal tract is achieved either in passive modality by utilizing the gut peristalsis (colon capsule) or in active " intelligent" modality by means of computer-assisted propulsion (robotic colonoscopy).In this review, the preliminary clinical results obtained with the new devices are summarized. It is expected that the new instruments will be soon available in clinical practice with the hope of increasing adherence to CRC screening programs.

Original languageEnglish
Pages (from-to)839-843
Number of pages5
JournalDigestive and Liver Disease
Volume42
Issue number12
DOIs
Publication statusPublished - Dec 2010

Fingerprint

Colonoscopy
Early Detection of Cancer
Ovum
Colorectal Neoplasms
Population
Robotics
Capsules
Colon
Peristalsis
Occult Blood
Mortality
Disinfection
General Practitioners
Italy
Fear
Gastrointestinal Tract
Technology
Morbidity
Pain
Equipment and Supplies

Keywords

  • Capsule endoscopy
  • Colonoscopy
  • Colorectal cancer
  • Colorectal screening
  • Disinfection
  • Robotic endoscopy

ASJC Scopus subject areas

  • Gastroenterology
  • Hepatology

Cite this

The intelligent, painless, " germ-free" colonoscopy : A Columbus' egg for increasing population adherence to colorectal cancer screening? / Perri, Francesco; Iacobellis, Angelo; Gentile, Marco; Tumino, Emanuele; Andriulli, Angelo.

In: Digestive and Liver Disease, Vol. 42, No. 12, 12.2010, p. 839-843.

Research output: Contribution to journalArticle

@article{0c2a25b783f8451e86df969c380050d7,
title = "The intelligent, painless, {"} germ-free{"} colonoscopy: A Columbus' egg for increasing population adherence to colorectal cancer screening?",
abstract = "Colorectal cancer (CRC) represents a major cause of morbidity and mortality. Although it is widely accepted that CRC screening in average risk populations lowers CRC incidence and mortality, a disappointedly low adherence rate to both faecal occult blood testing and colonoscopy-based screening programs has been observed in Italy and in other European countries. Main reasons for the low acceptance of colonoscopy-based CRC screening has been ascribed to lack of recommendations given by general practitioners, fear of discomfort or complications, embarrassment, and avoidance of unpleasant preparation.New advances in endoscopic technology such as colon capsule and robotic colonoscopy might represent the ideal tool for CRC screening since they reduce or eliminate procedure-related pain and discomfort. Moreover, no disinfection between procedures is required. Motion of the new probes along the gastrointestinal tract is achieved either in passive modality by utilizing the gut peristalsis (colon capsule) or in active {"} intelligent{"} modality by means of computer-assisted propulsion (robotic colonoscopy).In this review, the preliminary clinical results obtained with the new devices are summarized. It is expected that the new instruments will be soon available in clinical practice with the hope of increasing adherence to CRC screening programs.",
keywords = "Capsule endoscopy, Colonoscopy, Colorectal cancer, Colorectal screening, Disinfection, Robotic endoscopy",
author = "Francesco Perri and Angelo Iacobellis and Marco Gentile and Emanuele Tumino and Angelo Andriulli",
year = "2010",
month = "12",
doi = "10.1016/j.dld.2010.06.007",
language = "English",
volume = "42",
pages = "839--843",
journal = "Digestive and Liver Disease",
issn = "1590-8658",
publisher = "Elsevier B.V.",
number = "12",

}

TY - JOUR

T1 - The intelligent, painless, " germ-free" colonoscopy

T2 - A Columbus' egg for increasing population adherence to colorectal cancer screening?

AU - Perri, Francesco

AU - Iacobellis, Angelo

AU - Gentile, Marco

AU - Tumino, Emanuele

AU - Andriulli, Angelo

PY - 2010/12

Y1 - 2010/12

N2 - Colorectal cancer (CRC) represents a major cause of morbidity and mortality. Although it is widely accepted that CRC screening in average risk populations lowers CRC incidence and mortality, a disappointedly low adherence rate to both faecal occult blood testing and colonoscopy-based screening programs has been observed in Italy and in other European countries. Main reasons for the low acceptance of colonoscopy-based CRC screening has been ascribed to lack of recommendations given by general practitioners, fear of discomfort or complications, embarrassment, and avoidance of unpleasant preparation.New advances in endoscopic technology such as colon capsule and robotic colonoscopy might represent the ideal tool for CRC screening since they reduce or eliminate procedure-related pain and discomfort. Moreover, no disinfection between procedures is required. Motion of the new probes along the gastrointestinal tract is achieved either in passive modality by utilizing the gut peristalsis (colon capsule) or in active " intelligent" modality by means of computer-assisted propulsion (robotic colonoscopy).In this review, the preliminary clinical results obtained with the new devices are summarized. It is expected that the new instruments will be soon available in clinical practice with the hope of increasing adherence to CRC screening programs.

AB - Colorectal cancer (CRC) represents a major cause of morbidity and mortality. Although it is widely accepted that CRC screening in average risk populations lowers CRC incidence and mortality, a disappointedly low adherence rate to both faecal occult blood testing and colonoscopy-based screening programs has been observed in Italy and in other European countries. Main reasons for the low acceptance of colonoscopy-based CRC screening has been ascribed to lack of recommendations given by general practitioners, fear of discomfort or complications, embarrassment, and avoidance of unpleasant preparation.New advances in endoscopic technology such as colon capsule and robotic colonoscopy might represent the ideal tool for CRC screening since they reduce or eliminate procedure-related pain and discomfort. Moreover, no disinfection between procedures is required. Motion of the new probes along the gastrointestinal tract is achieved either in passive modality by utilizing the gut peristalsis (colon capsule) or in active " intelligent" modality by means of computer-assisted propulsion (robotic colonoscopy).In this review, the preliminary clinical results obtained with the new devices are summarized. It is expected that the new instruments will be soon available in clinical practice with the hope of increasing adherence to CRC screening programs.

KW - Capsule endoscopy

KW - Colonoscopy

KW - Colorectal cancer

KW - Colorectal screening

KW - Disinfection

KW - Robotic endoscopy

UR - http://www.scopus.com/inward/record.url?scp=78650290496&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78650290496&partnerID=8YFLogxK

U2 - 10.1016/j.dld.2010.06.007

DO - 10.1016/j.dld.2010.06.007

M3 - Article

VL - 42

SP - 839

EP - 843

JO - Digestive and Liver Disease

JF - Digestive and Liver Disease

SN - 1590-8658

IS - 12

ER -