Abstract
The difficult performance of certain percutaneous interventions in the field of congenital heart disease is well known. Crossing pulmonary arteries in patients who have previously undergone surgical repair or stenotic pulmonary veins in infants can be typical examples of these technical challenges in the catheterization laboratory. The Venture wire 6 Fr control catheter (St Jude Medical) is compatible with a steerable tapered radiopaque tip that can be manually angulated (up to 90°) by clockwise rotation of a knob located in the proximal handle. This mechanism directs any 0.014" guidewire and provides back-up support. This catheter has been successfully used in coronary artery intervention for crossing severely tortuous vessels, extreme angulations of side-branch ostia, jailed stents, saphenous vein graft anastomoses, and chronic total occlusions. We report the first use of the Venture wire control catheter (St Jude Medical) in the field of congenital heart disease. Patient #1 was diagnosed with pulmonary atresia and ventricular septal defect and had a proximally migrated stent in the pulmonary trunk and severe left pulmonary artery stenosis. We have used this catheter in order to cross this stent and perform left pulmonary artery stent placement. Patient #2 had postoperative vein restenosis after surgery. The Venture catheter was used to reach the obstructed insertion of the right medium lobe pulmonary vein from a transseptal approach. Techniques from coronary interventional colleagues can help interventional cardiologists in the field of congenital heart disease to treat complex situations.
Original language | English |
---|---|
Journal | Journal of Invasive Cardiology |
Volume | 24 |
Issue number | 7 |
Publication status | Published - Jul 2012 |
Fingerprint
Keywords
- congenital heart defects
- pulmonary artery
- pulmonary atresia
- stents
ASJC Scopus subject areas
- Cardiology and Cardiovascular Medicine
- Radiology Nuclear Medicine and imaging
Cite this
The use of a wire control catheter to treat complex pulmonary artery or vein anatomy. / Manica, Joao Luiz L; Piazza, Luciane; Butera, Gianfranco.
In: Journal of Invasive Cardiology, Vol. 24, No. 7, 07.2012.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - The use of a wire control catheter to treat complex pulmonary artery or vein anatomy
AU - Manica, Joao Luiz L
AU - Piazza, Luciane
AU - Butera, Gianfranco
PY - 2012/7
Y1 - 2012/7
N2 - The difficult performance of certain percutaneous interventions in the field of congenital heart disease is well known. Crossing pulmonary arteries in patients who have previously undergone surgical repair or stenotic pulmonary veins in infants can be typical examples of these technical challenges in the catheterization laboratory. The Venture wire 6 Fr control catheter (St Jude Medical) is compatible with a steerable tapered radiopaque tip that can be manually angulated (up to 90°) by clockwise rotation of a knob located in the proximal handle. This mechanism directs any 0.014" guidewire and provides back-up support. This catheter has been successfully used in coronary artery intervention for crossing severely tortuous vessels, extreme angulations of side-branch ostia, jailed stents, saphenous vein graft anastomoses, and chronic total occlusions. We report the first use of the Venture wire control catheter (St Jude Medical) in the field of congenital heart disease. Patient #1 was diagnosed with pulmonary atresia and ventricular septal defect and had a proximally migrated stent in the pulmonary trunk and severe left pulmonary artery stenosis. We have used this catheter in order to cross this stent and perform left pulmonary artery stent placement. Patient #2 had postoperative vein restenosis after surgery. The Venture catheter was used to reach the obstructed insertion of the right medium lobe pulmonary vein from a transseptal approach. Techniques from coronary interventional colleagues can help interventional cardiologists in the field of congenital heart disease to treat complex situations.
AB - The difficult performance of certain percutaneous interventions in the field of congenital heart disease is well known. Crossing pulmonary arteries in patients who have previously undergone surgical repair or stenotic pulmonary veins in infants can be typical examples of these technical challenges in the catheterization laboratory. The Venture wire 6 Fr control catheter (St Jude Medical) is compatible with a steerable tapered radiopaque tip that can be manually angulated (up to 90°) by clockwise rotation of a knob located in the proximal handle. This mechanism directs any 0.014" guidewire and provides back-up support. This catheter has been successfully used in coronary artery intervention for crossing severely tortuous vessels, extreme angulations of side-branch ostia, jailed stents, saphenous vein graft anastomoses, and chronic total occlusions. We report the first use of the Venture wire control catheter (St Jude Medical) in the field of congenital heart disease. Patient #1 was diagnosed with pulmonary atresia and ventricular septal defect and had a proximally migrated stent in the pulmonary trunk and severe left pulmonary artery stenosis. We have used this catheter in order to cross this stent and perform left pulmonary artery stent placement. Patient #2 had postoperative vein restenosis after surgery. The Venture catheter was used to reach the obstructed insertion of the right medium lobe pulmonary vein from a transseptal approach. Techniques from coronary interventional colleagues can help interventional cardiologists in the field of congenital heart disease to treat complex situations.
KW - congenital heart defects
KW - pulmonary artery
KW - pulmonary atresia
KW - stents
UR - http://www.scopus.com/inward/record.url?scp=84864344234&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84864344234&partnerID=8YFLogxK
M3 - Article
C2 - 22781486
AN - SCOPUS:84864344234
VL - 24
JO - Journal of Invasive Cardiology
JF - Journal of Invasive Cardiology
SN - 1042-3931
IS - 7
ER -