Treatment of acute respiratory failure with low-frequency positive-pressure ventilation and extracorporeal removal of CO2

L. Gattinoni, A. Agostoni, A. Pesenti, A. Pelizzola, G. P. Rossi, M. Langer, S. Vesconi, L. Uziel, U. Fox, F. Longoni, T. Kolobow, G. Damia

Research output: Contribution to journalArticle

171 Citations (Scopus)

Abstract

Terminal respiratory failure was reversed in 3 patients with a combination of extracorporeal CO2 removal through a membrane lung and oxygen diffusion into the diseased lungs between mechanical breaths induced at a frequency of 2-3/min. The technique seems to prevent the pulmonary barotrauma and extrapulmonary derangements caused by conventional mechanical ventilation.

Original languageEnglish
Pages (from-to)292-294
Number of pages3
JournalLancet
Volume2
Issue number8189
DOIs
Publication statusPublished - 1980

Fingerprint

Positive-Pressure Respiration
Respiratory Insufficiency
Barotrauma
Lung
Artificial Respiration
Lung Diseases
Oxygen
Membranes
Therapeutics

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Gattinoni, L., Agostoni, A., Pesenti, A., Pelizzola, A., Rossi, G. P., Langer, M., ... Damia, G. (1980). Treatment of acute respiratory failure with low-frequency positive-pressure ventilation and extracorporeal removal of CO2 Lancet, 2(8189), 292-294. https://doi.org/10.1016/S0140-6736(80)90237-8

Treatment of acute respiratory failure with low-frequency positive-pressure ventilation and extracorporeal removal of CO2 . / Gattinoni, L.; Agostoni, A.; Pesenti, A.; Pelizzola, A.; Rossi, G. P.; Langer, M.; Vesconi, S.; Uziel, L.; Fox, U.; Longoni, F.; Kolobow, T.; Damia, G.

In: Lancet, Vol. 2, No. 8189, 1980, p. 292-294.

Research output: Contribution to journalArticle

Gattinoni, L, Agostoni, A, Pesenti, A, Pelizzola, A, Rossi, GP, Langer, M, Vesconi, S, Uziel, L, Fox, U, Longoni, F, Kolobow, T & Damia, G 1980, 'Treatment of acute respiratory failure with low-frequency positive-pressure ventilation and extracorporeal removal of CO2 ', Lancet, vol. 2, no. 8189, pp. 292-294. https://doi.org/10.1016/S0140-6736(80)90237-8
Gattinoni, L. ; Agostoni, A. ; Pesenti, A. ; Pelizzola, A. ; Rossi, G. P. ; Langer, M. ; Vesconi, S. ; Uziel, L. ; Fox, U. ; Longoni, F. ; Kolobow, T. ; Damia, G. / Treatment of acute respiratory failure with low-frequency positive-pressure ventilation and extracorporeal removal of CO2 In: Lancet. 1980 ; Vol. 2, No. 8189. pp. 292-294.
@article{306404c42dca4131bf9899e8fa5027df,
title = "Treatment of acute respiratory failure with low-frequency positive-pressure ventilation and extracorporeal removal of CO2",
abstract = "Terminal respiratory failure was reversed in 3 patients with a combination of extracorporeal CO2 removal through a membrane lung and oxygen diffusion into the diseased lungs between mechanical breaths induced at a frequency of 2-3/min. The technique seems to prevent the pulmonary barotrauma and extrapulmonary derangements caused by conventional mechanical ventilation.",
author = "L. Gattinoni and A. Agostoni and A. Pesenti and A. Pelizzola and Rossi, {G. P.} and M. Langer and S. Vesconi and L. Uziel and U. Fox and F. Longoni and T. Kolobow and G. Damia",
year = "1980",
doi = "10.1016/S0140-6736(80)90237-8",
language = "English",
volume = "2",
pages = "292--294",
journal = "The Lancet",
issn = "0140-6736",
publisher = "Lancet Publishing Group",
number = "8189",

}

TY - JOUR

T1 - Treatment of acute respiratory failure with low-frequency positive-pressure ventilation and extracorporeal removal of CO2

AU - Gattinoni, L.

AU - Agostoni, A.

AU - Pesenti, A.

AU - Pelizzola, A.

AU - Rossi, G. P.

AU - Langer, M.

AU - Vesconi, S.

AU - Uziel, L.

AU - Fox, U.

AU - Longoni, F.

AU - Kolobow, T.

AU - Damia, G.

PY - 1980

Y1 - 1980

N2 - Terminal respiratory failure was reversed in 3 patients with a combination of extracorporeal CO2 removal through a membrane lung and oxygen diffusion into the diseased lungs between mechanical breaths induced at a frequency of 2-3/min. The technique seems to prevent the pulmonary barotrauma and extrapulmonary derangements caused by conventional mechanical ventilation.

AB - Terminal respiratory failure was reversed in 3 patients with a combination of extracorporeal CO2 removal through a membrane lung and oxygen diffusion into the diseased lungs between mechanical breaths induced at a frequency of 2-3/min. The technique seems to prevent the pulmonary barotrauma and extrapulmonary derangements caused by conventional mechanical ventilation.

UR - http://www.scopus.com/inward/record.url?scp=0018849961&partnerID=8YFLogxK